Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Lead V1 on electrocardiography (ECG) can detect the dominant frequency (DF) of atrial fibrillation (AF) in the right atrium (RA). Paroxysmal AF is characterized by a frequency gradient from the left atrium (LA) to the right atrium (RA). We examined the ability of magnetocardiography (MCG) to detect regional DFs in both the atria.

Methods: Study subjects comprised 18 consecutive patients referred for catheter ablation of persistent AF. An MCG system with 64 magnetic sensors was used to perform MCG in the frontal, lateral, and back planes prior to the ablation procedure in each patient. DFMCG and organization index (OIMCG) were calculated using fast Fourier transformation. Intracardiac electrograms (ICEs) in both the atria and the coronary sinus (CS) were mapped at 17 sites. Regional DFsICE were also determined.

Results: Mean LA DFICE was higher than mean RA DFICE (6.40±0.66 versus 6.16±0.80 Hz, P=0.03). DFMCG in the channel having the highest OIMCG was 6.61±0.88 Hz in the frontal plane, 6.52±0.64 Hz in the lateral plane, and 6.42±0.62 Hz in the back plane (P=0.3). In each plane, DFMCG correlated with DFICE at the RA appendage (R=0.95, P<0.0001), the LA appendage (R=0.91, P<0.0001), and the CS (R=0.93, P<0.0001). DFECG in V5 modestly correlated with DFICE at the LA appendage (R=0.82, P<0.0001).

Conclusions: MCG could more precisely detect the DFs in the LA and the CS than ECG. However, the usefulness of pre-procedural detection of the AF frequency gradient for ablation therapy needs to be evaluated in future prospective studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4672036PMC
http://dx.doi.org/10.1016/j.joa.2015.05.003DOI Listing

Publication Analysis

Top Keywords

ability magnetocardiography
8
detect regional
8
atrial fibrillation
8
magnetocardiography detect
4
regional dominant
4
dominant frequencies
4
frequencies atrial
4
fibrillation background
4
background lead
4
lead electrocardiography
4

Similar Publications

Despite cognitive workload (CW) being a critical metric in several applications, no technology exists to seamlessly and reliably quantify CW. Previously, we demonstrated the feasibility of a wearable MagnetoCardioGraphy (MCG) sensor to classify high vs. low CW based on MCG-derived heart rate variability (mHRV).

View Article and Find Full Text PDF

Automated analytical techniques for magnetocardiography (MCG) are essential for diagnosing and predicting cardiovascular diseases. Clinically acquired MCG signals are often contaminated by various types of noise, which negatively impact subsequent signal analysis. However, traditional methods have limitations in denoising long-term MCG signals with complex spatial structures.

View Article and Find Full Text PDF

With the gradual maturation of optically pumped magnetometer (OPM) technology, the use of OPMs to acquire weak magnetocardiography (MCG) signals has started to gain widespread application. Due to the complexity of magnetic environments, MCG signals are often subject to interference from various unknown sources. Independent component analysis (ICA) is one of the most widely used methods for blind source separation.

View Article and Find Full Text PDF

Decades of experimental and clinical studies, along with the most recent clinical trials, have demonstrated the diagnostic potential of magnetocardiography, particularly for the non-invasive early diagnosis of myocardial ischemia. It has also proven to be a valuable clinical tool for monitoring fetal well-being, normal growth, prenatal arrhythmias, and risk markers for sudden death. Such applications have recently received official recognition from Health Canada and the American Heart Association.

View Article and Find Full Text PDF

Fetal magnetocardiography (fMCG) is a non-invasive technique that measures the magnetic fields associated with fetal heart electrical activity outside of the maternal abdomen. fMCG has high temporal precision for measuring fetal heart rate and its variability which reflects fetal neurodevelopment. Free of cryogenics and low-cost sensors called microfabricated optically pumped magnetometers (OPMs) have emerged as an alternate to cryogenic SQUID (Superconducting Quantum Interference Device) systems to record fMCG.

View Article and Find Full Text PDF