98%
921
2 minutes
20
While the assessment of CT noise constitutes an important task for the optimization of scan protocols in clinical routine, the majority of noise measurements in practice still rely on manual operation, hence limiting their efficiency and reliability. This study presents an algorithm for the automated measurement of CT noise in patient images with a novel structure coherence feature. The proposed algorithm consists of a four-step procedure including subcutaneous fat tissue selection, the calculation of structure coherence feature, the determination of homogeneous ROIs, and the estimation of the average noise level. In an evaluation with 94 CT scans (16 517 images) of pediatric and adult patients along with the participation of two radiologists, ROIs were placed on a homogeneous fat region at 99.46% accuracy, and the agreement of the automated noise measurements with the radiologists' reference noise measurements (PCC = 0.86) was substantially higher than the within and between-rater agreements of noise measurements (PCCwithin = 0.75, PCCbetween = 0.70). In addition, the absolute noise level measurements matched closely the theoretical noise levels generated by a reduced-dose simulation technique. Our proposed algorithm has the potential to be used for examining the appropriateness of radiation dose and the image quality of CT protocols for research purposes as well as clinical routine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/60/23/9107 | DOI Listing |
Jpn J Radiol
September 2025
Department of Radiology, the Affiliated Hospital of Xuzhou Medical University, Xuzhou, 221002, Jiangsu, China.
Background: Stroke, frequently associated with carotid artery disease, is evaluated using carotid computed tomography angiography (CTA). Dual-energy CTA (DE-CTA) enhances imaging quality but presents challenges in maintaining high image clarity with low-dose scans.
Objectives: To compare the image quality of 50 keV virtual monoenergetic images (VMI) generated using Deep Learning Image Reconstruction (DLIR) and Adaptive Statistical Iterative Reconstruction-V (ASIR-V) algorithms under a triple-low scanning protocol in carotid CTA.
J Acoust Soc Am
September 2025
Department of Physics, University of Louisiana at Lafayette, Lafayette, Louisiana 70503, USA.
A method is presented for determining the significant parameters, maximum wind speed and radius of maximum wind speed, of the surface winds associated with a hurricane. The method is based on Bayesian inversion, using Markov chain Monte Carlo sampling. Underwater acoustic measurements are used to estimate parameters in the axisymmetric Holland model for hurricane surface winds.
View Article and Find Full Text PDFAdv Mater
September 2025
Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, 37673, South Korea.
Wearable bioelectronics have advanced dramatically over the past decade, yet remain constrained by their superficial placement on the skin, which renders them vulnerable to environmental fluctuations and mechanical instability. Existing microneedle (MN) electrodes offer minimally invasive access to dermal tissue, but their rigid, bulky design-often 100 times larger and 10,000 times stiffer than dermal fibroblasts-induces pain, tissue damage, and chronic inflammation, limiting their long-term applicability. Here, a cell-stress-free percutaneous bioelectrode is presented, comprising an ultrathin (<2 µm), soft MN (sMN) that dynamically softens via an effervescent structural transformation after insertion.
View Article and Find Full Text PDFEnviron Res
September 2025
Department of Occupational Safety and Health, College of Public Health, China Medical University, Taichung, Taiwan. Electronic address:
Limited research has examined the relationships of co-exposure to air pollutants, temperature, and road traffic noise with chronic kidney disease (CKD) incidence and the interaction between PM and temperature. To address this gap, the present study explored these associations and interactions in Taiwan. A cohort of 3,041 older individuals (aged ≥55 years) was recruited in 2009 and followed until 2019.
View Article and Find Full Text PDFEnviron Res
September 2025
Department of Occupational Health Engineering, Tehran University of Medical Sciences, Tehran, Iran. Electronic address:
Animal studies indicating an association of exposure to extremely low frequency electromagnetic fields (ELF-EMFs) and noise with reproductive dysfunctions. Nonetheless, the potential impacts of exposure to these hazardous agents on the human prostate gland remain unidentified. To assess the relationship between co-exposure to ELF-EMF and noise and the levels of prostate-specific antigen (PSA), a longitudinal study was conducted over eight years among workers at a thermal power station from 2016 to 2024.
View Article and Find Full Text PDF