Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Several clinical prediction schemes for right ventricular failure (RVF) risk after left ventricular assist device (LVAD) implantation have been developed in both the pulsatile- and continuous-flow LVAD eras. The performance of these models has not been evaluated systematically in a continuous-flow LVAD cohort.

Methods: We evaluated 6 clinical RVF prediction models (Michigan, Penn, Utah, Kormos et al, CRITT, Pittsburgh Decision Tree) in 116 patients (age 51 ± 13 years; 41.4% white and 56.0% black; 66.4% men; 56.0% bridge to transplant, 37.1% destination therapy, 17.4% bridge to decision) who received a continuous-flow LVAD (HeartMate II: 79 patients, HeartWare: 37 patients) between 2008 and 2013.

Results: Overall, 37 patients (31.9%) developed RVF, defined: as pulmonary vasodilator use for ≥48 hours or inotrope use for ≥14 days post-operatively; re-institution of inotropes; multi-organ failure due to RVF; or need for mechanical RV support. Median (Quartile 1 to Quartile 3) time to initial discontinuation of inotropes was 6 (range 4 to 8) days. Among scores, the Michigan score reached significance for RVF prediction but discrimination was modest (C = 0.62 [95% CI 0.52 to 0.72], p = 0.021; positive predictive value [PPV] 60.0%; negative predictive value [NPV] 75.8%), followed by CRITT (C = 0.60 [95% CI 0.50 to 0.71], p = 0.059; PPV 40.5%; NPV 72.2%). Other models did not significantly discriminate RVF. The newer, INTERMACS 3.0 definition for RVF, which includes inotropic support beyond 7 days, was reached by 57 patients (49.1%). The Kormos model performed best with this definition (C = 0.62 [95% CI 0.54 to 0.71], p = 0.005; PPV 64.3%; NPV 59.5%), followed by Penn (C = 0.61), Michigan (C = 0.60) and CRITT (C = 0.60), but overall score performance was modest.

Conclusion: Current schemes for post-LVAD RVF risk prediction perform only modestly when applied to external populations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.healun.2015.05.005DOI Listing

Publication Analysis

Top Keywords

continuous-flow lvad
12
ventricular failure
8
left ventricular
8
ventricular assist
8
rvf
8
failure rvf
8
rvf risk
8
rvf prediction
8
062 [95%
8
critt 060
8

Similar Publications

Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.

View Article and Find Full Text PDF

Long Term Outcomes of Tricuspid Valve Repair or Replacement in Patients with Continuous Flow Left Ventricular Assist Devices.

J Thorac Cardiovasc Surg

September 2025

Division of Cardiac, Thoracic & Vascular Surgery, Department of Surgery, Columbia University Irving Medical Center, NewYork-Presbyterian Hospital, New York, NY. Electronic address:

Objective: Our objective was to determine the long-term outcomes of concomitant tricuspid valve procedures (TVP) during continuous-flow left ventricular assist device (LVAD) implantation.

Methods: We retrospectively reviewed patients who received HeartMate II or 3 from 2004 to 2023. Nine patients who had a previous TVP were excluded.

View Article and Find Full Text PDF

The first successful implantation of the HeartMate 3 LVAD in Iraq represents a transformative achievement in the nation's medical history. Conducted collaboratively by German and Iraqi teams in December 2023, the procedure addressed end-stage heart failure in a 60-year-old male. Despite significant healthcare challenges, the patient's functional status improved markedly, moving from New York Heart Association Class IV to Class I within a year.

View Article and Find Full Text PDF

Background: Left ventricular assist devices (LVAD) are a bridge to heart transplantation (HT). Given limited donor organs, assessment of risk of waitlist mortality is important for waitlist prioritization for HT. We sought to derive and validate a risk prediction model for waitlist mortality in LVAD patients.

View Article and Find Full Text PDF

Physiologic effects of different hemodynamic patterns of LVAD.

Front Cardiovasc Med

August 2025

Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Left ventricular assist device (LVAD) is an important treatment for patients with end-stage heart failure, which essentially replaces the left ventricle's pumping action to improve peripheral circulation. Its hemodynamic pattern (pulsatile vs. continuous flow) has been a popular research topic in the field.

View Article and Find Full Text PDF