Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Available measurement methods for nanomaterials are based on very different measurement principles and hence produce different values when used on aggregated nanoparticle dispersions. This paper provides a solution for relating measurements of nanomaterials comprised of nanoparticle aggregates determined by different techniques using a uniform expression of a mass equivalent diameter (MED). The obtained solution is used to transform into MED the size distributions of the same sample of synthetic amorphous silica (nanomaterial comprising aggregated nanoparticles) measured by six different techniques: scanning electron microscopy in both high vacuum (SEM) and liquid cell setup (Wet-SEM); gas-phase electrophoretic mobility molecular analyzer (GEMMA); centrifugal liquid sedimentation (CLS); nanoparticle tracking analysis (NTA); and asymmetric flow field flow fractionation with inductively coupled plasma mass spectrometry detection (AF4-ICP-MS). Transformed size distributions are then compared between the methods and conclusions drawn on methods' measurement accuracy, limits of detection and quantification related to the synthetic amorphous silca's size. Two out of the six tested methods (GEMMA and AF4-ICP-MS) cross validate the MED distributions between each other, providing a true measurement. The measurement accuracy of other four techniques is shown to be compromised either by the high limit of detection and quantification (CLS, NTA, Wet-SEM) or the sample preparation that is biased by increased retention of smaller nanomaterials (SEM). This study thereby presents a successful and conclusive cross-method comparison of size distribution measurements of aggregated nanomaterials. The authors recommend the uniform MED size expression for application in nanomaterial risk assessment studies and clarifications in current regulations and definitions concerning nanomaterials.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c5an00561bDOI Listing

Publication Analysis

Top Keywords

size distributions
12
med size
8
synthetic amorphous
8
measurement accuracy
8
detection quantification
8
size
6
measurement
5
nanomaterials
5
uniform measurement
4
measurement expression
4

Similar Publications

Purpose: Primary ventral hernia repair is a common elective procedure; however, mesh placement practices vary widely, and there is limited evidence to guide optimal placement. This international study examined surgeons' preferences and considerations regarding mesh placement in elective primary ventral hernia repair.

Methods: We conducted an international cross-sectional survey targeting surgeons experienced in primary ventral hernia repair.

View Article and Find Full Text PDF

The Atlantification of the Arctic is driving a northward habitat shift of many cetaceans, including sperm whales (Physeter macrocephalus). As Arctic warming continues to decrease sea ice extent and contributes to the change in species distributions, it is crucial to study how the distribution patterns, habitat, and the demographic structure of sperm whale populations may continue to change. In this study, we assess the temporal presence of echolocating sperm whales on the continental slope southwest of the Svalbard archipelago and compare it with acoustic backscatter and temperature as a proxy for biomass.

View Article and Find Full Text PDF

Genomes are composed of a mosaic of segments inherited from different ancestors, each separated by past recombination events. Consequently, genealogical relationships among multiple genomes vary spatially across different genomic regions. Genealogical variation among unlinked (uncorrelated) genomic regions is well described for either a single population (coalescent) or multiple structured populations (multispecies coalescent).

View Article and Find Full Text PDF

First-principles insights into structure and magnetism in ultra-small tetrahedral iron oxide nanoparticles.

Phys Chem Chem Phys

September 2025

Masaryk University, Faculty of Science, Department of Chemistry, Kotlářská 2, Brno, 611 37, Czech Republic.

Structural and magnetic properties of ultra-small tetrahedron-shaped iron oxide nanoparticles were investigated using density functional theory. Tetrahedral and truncated tetrahedral models were considered in both non-functionalized form and with surfaces passivated by pseudo-hydrogen atoms. The focus on these two morphologies reflects their experimental relevance at this size scale and the feasibility of performing fully relaxed, atomistically resolved first-principles simulations.

View Article and Find Full Text PDF

Comparison of parametric and hybrid methods for estimating mean survival time in clinical study.

J Biopharm Stat

September 2025

Department of Information and Computer Technology, Faculty of Engineering, Tokyo University of Science, Tokyo, Japan.

The mean survival time (MST) is usually estimated as the area under the curve of the estimated survival function obtained using the Kaplan-Meier method. However, when the maximum observed survival time is censored, the MST cannot be estimated because the survival function does not reach zero. In such cases, parametric and hybrid methods are used to estimate the MST.

View Article and Find Full Text PDF