98%
921
2 minutes
20
Objective: The objective of this study was to review the current anatomic indications for and early results of aortouni-iliac (AUI) devices for endovascular aneurysm repair.
Methods: A total of 128 patients receiving an Endurant (Medtronic Inc, Minneapolis, Minn) AUI device in the U.S. Investigational Device Exemption trial (44 patients) or the Endurant Stent Graft Natural Selection Global Postmarket Registry (84 patients) were reviewed. Preoperative computed tomography imaging of patients in the Investigational Device Exemption trial and case report forms of Registry patients were used to determine anatomic indications. Baseline characteristics and early results were compared with those of 1305 patients receiving a bifurcated (BIF) device in sister studies.
Results: The indication for the AUI device was unclear from case report forms in two Registry cases. The remaining 126 patients had a unilateral iliac occlusion in 30 (23%), a severely narrowed aortic segment in 58 (45%), severe iliac occlusive disease in 28 (22%), severe iliac tortuosity in 29 (23%), or complex iliac aneurysms in 19 (15%). Two patients had a previous aortobifemoral graft; 38 patients (30%) had multiple indications. The AUI cohort included more women than the BIF group did (19% vs 10%; P < .01) and had more severe comorbidities. Successful deployment was achieved in all AUI cases. The 30-day mortality was 2% (BIF cohort, 1%; P = .21). More AUI patients underwent repair under general anesthesia (81% vs 64%; P < .01), and procedures were longer (110.9 ± 54.9 minutes vs 99.2 ± 44.3 minutes; P = .02). Except for longer intensive care unit stays (19.6 ± 80.0 hours vs 9.0 ± 34.8 hours; P = .01) and higher myocardial infarction rates (4% vs 1%; P < .01), outcomes of the AUI cohort were similar to those of the BIF cohort. There were no migrations, ruptures, fractures, or open conversions at up to 1-year follow-up.
Conclusions: The AUI configuration extends endovascular aneurysm repair feasibility to several hostile anatomic conditions. Despite increased comorbidities in the recipient patient population and associated higher rates of postoperative myocardial infarction and respiratory complications, early outcomes with the new generation of AUI devices are acceptable and comparable to those after treatment with BIF configurations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2014.08.063 | DOI Listing |
Eur J Vasc Endovasc Surg
September 2025
Department of Surgical Sciences, Section of Vascular Surgery, Uppsala University, Uppsala, Sweden.
Objective: To examine trends in treatment strategies and perioperative outcomes for intact and ruptured complex abdominal aortic aneurysms (cAAA) across seven countries.
Design: Multinational, registry-based observational study within the VASCUNET framework.
Methods: This study used aggregated data from vascular registries in Australia, Denmark, Finland, New Zealand, Portugal, Sweden, and Switzerland.
Eur J Vasc Endovasc Surg
September 2025
Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Objective: This study aimed to use quantitative magnetic resonance angiography (qMRA) to investigate the haemodynamic influences on cerebral circulation after hybrid thoracic endovascular aortic repair (TEVAR).
Methods: Between January 2016 and October 2019, zone 1 and 2 TEVAR with supra-arch rerouting procedure in extra-anatomical fashion was performed in 24 patients (mean age 72.9 ± 11.
Rev Esp Anestesiol Reanim (Engl Ed)
September 2025
Servicio de Angiología y Cirugía Vascular, Hospital Universitario San Cecilio, Granada, Spain.
Endovascular aortic arch surgery is an evolving field that offers less invasive alternatives to open surgery. The emergence of new devices and their implantation imply new considerations in the management by the anaesthesiologist during the procedure. An example of this is the NEXUS TRE™ stent, designed to preserve the patency of the supra-aortic trunks without the need for extra-anatomic bypass.
View Article and Find Full Text PDFClin Neurol Neurosurg
September 2025
Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
Objective: Delayed cerebral ischemia (DCI) following aneurysmal subarachnoid hemorrhage (aSAH) is a major cause of morbidity and mortality. Symptoms of DCI can be categorized as temporary or permanent; however, the relationship between DCI and angiographic vasospasm (AVS) remains unclear. Therefore, this study aimed to clarify the relationship between DCI and AVS and to identify the factors associated with DCI in patients with aSAH.
View Article and Find Full Text PDFExp Ther Med
November 2025
Department of Neurosurgery, Nanchong Shenxin Hospital, Nanchong, Sichuan 637003, P.R. China.
Wide-necked anterior communicating artery (ACoA) aneurysms pose challenges for endovascular coiling due to the risk of coil protrusion. This case report describes a new endovascular technique for managing ruptured wide-necked ACoA aneurysms, addressing the risk of coil protrusion during embolization. This method employs a combined microcatheter and guidewire-assisted embolization method, enabling coil deployment without needing adjunctive devices such as stents or balloons.
View Article and Find Full Text PDF