Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In a laboratory setting where both a mechanically-braked cycling ergometer and a motion analysis (MA) system are available, flywheel angular displacement can be estimated by using MA. The purpose of this investigation was to assess the validity and reliability of a MA method for measuring maximal power output (Pmax) in comparison with a force transducer (FT) method. Eight males and eight females undertook three identical sessions, separated by 4 to 6 days; the first being a familiarization session. Individuals performed three 6-second sprints against 50% of the maximal resistance to complete two pedal revolutions with a 3-minute rest between trials. Power was determined independently using both MA and FT analyses. Validity: MA recorded significantly higher Pmax than FT (P < .05). Bland-Altman plots showed that there was a systematic bias in the difference between the measures of the two systems. This difference increased as power increased. Repeatability: Intraclass correlation coefficients were on average 0.90 ± 0.05 in males and 0.85 ± 0.08 in females. Measuring Pmax by MA, therefore, is as appropriate for use in exercise physiology research as Pmax measured by FT, provided that a bias between these measurements methods is allowed for.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jab.2013-0317DOI Listing

Publication Analysis

Top Keywords

validity reliability
8
method measuring
8
power output
8
reliability alternative
4
alternative method
4
power
4
measuring power
4
output six-second
4
six-second all-out
4
all-out cycling
4

Similar Publications

Background: The success of disease registry systems (DRSs) depends on developing software that aligns with the registry's specific needs.

Objective: This study focuses on localising the Checklist with Items for Patient Registry sOftware Systems (CIPROS) to facilitate the DRS assessment.

Method: This applied and cross-sectional study was carried out in 2023 in six phases.

View Article and Find Full Text PDF

Objective: Pain hypersensitivity and hypersensitivity to other sensory modalities (visual, auditory, olfactory, and tactile) are considered defining features in nociplastic pain states. A self-report measure of sensory sensitivity may help to characterize sensory profiles across pain populations. This study aimed to evaluate the psychometric properties of a newly developed Danish nine-item Sensory Sensitivity Profile (SSP) questionnaire in patients with fibromyalgia.

View Article and Find Full Text PDF

Background: Metabolic reprogramming is an important hallmark of cervical cancer (CC), and extensive studies have provided important information for translational and clinical oncology. Here we sought to determine metabolic association with molecular aberrations, telomere maintenance and outcomes in CC.

Methods: RNA sequencing data from TCGA cohort of CC was analyzed for their metabolic gene expression profile and consensus clustering was then performed to classify tumors into different groups/subtypes.

View Article and Find Full Text PDF

Chronic Obstructive Pulmonary Disease (COPD) is a prevalent chronic respiratory disorder characterized by airway inflammation and irreversible airflow limitation. Its marked heterogeneity and complexity pose significant challenges to traditional clinical assessments in terms of prognostic prediction and personalized management. In recent years, the exploration of biomarkers has opened new avenues for the precise evaluation of COPD, particularly through multi-biomarker prediction models and integrative multimodal data strategies, which have substantially improved the accuracy and reliability of prognostic assessments.

View Article and Find Full Text PDF