Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The black-and-white patterning of tendon fascicles when visualized by light microscopy, also known as crimp, is a well-known feature of fiber-forming collagens. However, not much is known about its development, function and response to strain. The objective of this study is to investigate the interaction of tenocyte and crimp morphology as well as their changes with increasing age and acute strain. In contrast to previous studies, which used indirect measures, such as polarized light, to investigate the crimp structure, this study visualizes internal crimp structure in three dimensions without freezing, sectioning, staining or fixing the tissue, via two-photon imaging of green fluorescent protein expressing cells within mouse tail tendon fascicles. This technique further allows straining of the live tissue while visualizing changes in crimp morphology and cell shape with increasing specimen length. Combining this novel microscopy technique with computational image and data analysis revealed a complex relationship between tenocytes and the extracellular matrix that evolves with increasing age. While the reduction of crimping with strain was observed as expected, most of the crimps were gone at 0-1% strain already. Even relatively low strains of 3% led to pronounced changes in the crimp structure after relaxation, particularly in the young animals, which could not be seen with bright-field imaging. Cell length and gap width increased with strain. However, while the cells were able to return to their original length even after high strains of 6%, the gaps between the cells widened, which may imply modified cell-cell communication after overstretching.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2014.05.029DOI Listing

Publication Analysis

Top Keywords

crimp structure
16
cell length
8
length gap
8
gap width
8
tendon fascicles
8
crimp morphology
8
increasing age
8
changes crimp
8
crimp
7
strain
6

Similar Publications

This study investigates and discusses the thread crimp in the jacquard woven two-dimensional (2D) fabrics. The study of thread crimp is important for technologists and weavers from a practical point of view, as it has a considerable influence on the behavior of the fabric during weaving on the weaving machine, and subsequently in the finishing process. The basis of the study is the creation of an analytical approach that allows estimating the thread crimp before weaving.

View Article and Find Full Text PDF

This study is among the first to characterize the tensile response of composites with quadriaxial glass fiber fabrics designed for marine structural applications. Four composite configurations were fabricated at laboratory scale, combining two matrix types (unsaturated polyester resin and epoxy resin) and the presence or absence of a Coremat Xi3 middle layer. Tensile tests were conducted at four test rates (10 mm/min, 200 mm/min, 500 mm/min, and 1000 mm/min), ranging from quasi-static to moderately dynamic conditions.

View Article and Find Full Text PDF

Temperature-based protection of biochemical and biomechanical characteristics during 25 kGy Co irradiation for allograft tendons.

BMC Musculoskelet Disord

August 2025

Department of Bone and Soft Tissue Oncology, Tianjin Hospital, Tianjin University, No. 406, Jiefang Southern Road, Hexi District, Tianjin, 300029, China.

Background: While prior studies have investigated cryopreservation, cross-linkers, and radical scavengers for tendon irradiation protection, optimal implementation protocols remain underexplored. We specifically evaluated temperature-dependent efficacy in preserving human tibialis posterior allograft tendons during 25kgy γ-irradiation.

Methods: Twenty-four human tibialis posterior tendons were irradiated at -70 °C, 0 °C and room temperature.

View Article and Find Full Text PDF

Measuring Stress on a Third-Generation Balloon-Expandable Aortic Valve During Expansion.

J Vis Exp

July 2025

Department of Cardiothoracic Surgery, University of Cincinnati College of Medicine; Department of Cardiothoracic Surgery, Mayo Clinic, Rochester.

This study aimed to determine the mechanical stresses experienced by third-generation, balloon-expandable transcatheter aortic valves in the presence of aortic calcification, defined by an elevated Agatston score index for calcium. The device under investigation was the Edwards SAPIEN 3 valve (referred to as S3-TAV henceforth), a 26-mm commercial device. Five steps were undertaken.

View Article and Find Full Text PDF

Influence of Stent Structure on Mechanical and Degradation Properties of Poly (Lactic Acid) Vascular Stent.

J Funct Biomater

July 2025

Biomechanics Laboratory, School of Biological Science & Medical Engineering, Southeast University, Nanjing 210096, China.

Biodegradable vascular stents (BVSs) face challenges related to inadequate mechanical strength, which can lead to adverse clinical outcomes. Improving the mechanical behavior of biodegradable vascular stents through structural design has been extensively explored. However, the corresponding effects of these mechanical enhancements on degradation characteristics remain under-investigated.

View Article and Find Full Text PDF