Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The standard bifrontal application of the bispectral index (BIS) sensor interferes with the operative field in neurosurgery and plastic surgery. The aim of this study was to compare the standard frontal BIS sensor position with an alternative position across the mandible.

Methods: Two BIS™ Quatro sensors (Aspect Medical Systems, Newton, MA, USA) mounted on the frontal and mandibular regions were connected to BIS Vista™ monitors on each patient during general anesthesia. Data from each position were collected at awake, loss of consciousness, intubation, incision, every 30 minutes during the intraoperative period and emergence. These data were compared using Bland-Altman and scatter plot analyses.

Results: Scatter plot analysis revealed a significant correlation between BIS values of frontal and mandibular positions (R = 0.869, P = 0.000), except during emergence (R = 0.253, P = 0.077). Bland-Altman analysis revealed a negative bias of 3.2 with a limit of agreement of 16.5/-22.9, in which 3.7% of the values were outside of the limit of agreement. Additional values included -2.9 (14.1/-8.3) while patients were awake, -21.7 (14.9/-58.3) at loss of consciousness, -1.8 (9.0/-12.5) during maintenance, and -1.9 (14.9/-18.8) during emergence.

Conclusions: Overall, BIS values do not agree between the standard frontal position and an alternative mandibular position. However, during the anesthesia maintenance period, the mandibular position can be availably used as an alternative position if the operative field renders the standard frontal position unavailable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4028552PMC
http://dx.doi.org/10.4097/kjae.2014.66.4.267DOI Listing

Publication Analysis

Top Keywords

standard frontal
16
position alternative
12
mandibular position
12
position
10
sensor position
8
alternative mandibular
8
bis sensor
8
operative field
8
alternative position
8
frontal mandibular
8

Similar Publications

Assessing the reproducibility of facebow transfers: A mesh-based intra-observer study.

J Prosthet Dent

September 2025

Assistant Professor, Department of Prosthetic Dentistry, UFR of Dental Sciences, Health College, University of Bordeaux, Bordeaux, France; and Researcher, University of Bordeaux, CNRS, Ministry of Culture, PACEA, UMR 5199, Pessac, France. Electronic address:

Statement Of Problem: The reproducibility of positioning the maxillary occlusal plane in an articulator with a facebow remains debated. Its clinical use is widespread, yet its reliability and clinical outcomes compared to other transfer methods under standardized conditions remain uncertain.

Purpose: The purpose of this in vitro study was to compare the intra-operator reproducibility of maxillary positioning on an articulator using a facebow compared to a standardized transfer table.

View Article and Find Full Text PDF

Cortical Thinning and Microstructural Integrity Disruption in White Matter Hyperintensities.

Brain Res Bull

September 2025

Department of Neurology, The Second Affiliated Hospital of Anhui Medical University, 230601, He Fei, China; Collaborative Innovation Center of Neuropsychiatric Disorders and Mental Health, 230032, Hefei, China; Anhui Province Key Laboratory of Cognition and Neuropsychiatric Disorders, 230032, Hefei,

Background: The relationships between white matter microstructure, cortical atrophy, and cognitive function in cerebral small vessel disease (CSVD)-related white matter hyperintensities (WMHs) patients are unclear.

Methods: 71 right-handed WMHs patients (mild, n=23; moderate, n=27; severe, n=21) and 35 healthy controls were included. Tract-based spatial statistics (TBSS) assessed microstructure via fractional anisotropy (FA) and mean diffusivity (MD).

View Article and Find Full Text PDF

Objectives: This study aimed to examine physical and craniofacial growth patterns in preschool-aged children with microcephaly and evaluate their potential clinical significance.

Methods: A total of 130 children (76 boys, 54 girls) aged 1-5 years with microcephaly (head circumference <-3 standard deviations) were enrolled in this prospective study at a tertiary care hospital, with 130 age- and sex-matched healthy controls. Nine craniofacial dimensions (head circumference, head length, head width, physiognomic facial length, morphological facial length, minimum frontal diameter, bizygomatic diameter, bigonial diameter, and total jaw height) were measured every six months using standardized techniques and instruments.

View Article and Find Full Text PDF

The functional interaction of regulatory mechanisms that manage total centre of mass (CoM) energy, frontal plane whole-body angular momentum and mediolateral margin of stability (MoS) during hole negotiation gait was investigated. Joint kinematics, leg posture, total CoM energy, frontal plane whole-body angular momentum, mediolateral MoS and muscle activation patterns of seven bilateral lower leg muscles were assessed in 18 participants. During hole negotiation, we found an increase in the peak-to-peak range of total CoM energy and frontal plane whole-body angular momentum during the preparation, hole and recovery steps, and a decrease in mediolateral MoS at touch-down during the preparation and hole steps compared to level walking, providing evidence of an increased challenge in stability control.

View Article and Find Full Text PDF

Occipital Monitoring of PSI During Frontal Tumor Resection: A Feasibility Study.

World Neurosurg

September 2025

Department of Anesthesiology, Xuanwu Hospital, Capital Medical University, Beijing, China. Electronic address:

Background: Frontal patient state index (PSI) monitoring is impractical during frontal lobe tumor resection due to surgical field interference. No validated alternative monitoring positions exist currently. This study evaluated the agreement between standard frontal and experimental occipital PSI monitoring.

View Article and Find Full Text PDF