98%
921
2 minutes
20
A highly selective amperometric sensor was developed for the trace level determination of hydrazine at bismuth nanoparticles (Bi) decorated graphene nanosheets (GR) composite film modified glassy carbon electrode (GCE). GR-Bi nanocomposite has been successfully prepared via simple and facile chemical reduction approach and its structure was characterized by various techniques. Surface morphological and X-ray diffraction studies revealed the formation and high loading of Bi nanoparticles on graphene sheets. GR-Bi nanocomposite modified GCE exhibited greatly enhanced electrocatalytic performance towards electro-oxidation of hydrazine in terms of decrease in overpotential and increase in oxidation peak current (Ip). The kinetic parameters such as electron transfer coefficient (α) and diffusion coefficient (Do) of the hydrazine oxidation were determined to be 0.70 and 2.65×10(-5) cm(2) s(-1), respectively. An amperometric sensor has been fabricated which detects trace level concentration of hydrazine. The sensor exhibited a wide linear range from 20 nM to 0.28 mM and a very low detection limit (LOD) of 5 nM. Remarkably, this is the lowest LOD achieved for the determination of hydrazine in neutral pH among other reported electrochemical hydrazine sensors. In addition, the sensor selectively detects hydrazine even in the presence of 1000 fold excess quantity of common interferrants. The practical feasibility of the sensor has been assessed in water and urine samples with good recoveries. Furthermore, the sensor exhibited appreciable stability, repeatability and reproducibility results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2014.02.031 | DOI Listing |
Cell Physiol Biochem
August 2025
Departamento de Procesos Químicos, Alimentos y Biotecnología. Facultad de Ingeniería y Ciencias Aplicadas. Universidad Técnica de Manabí, Portoviejo, Ecuador.
Background/aims: The quantification of amino acids in the dairy industry is necessary for quality control and for the formulation of functional foods. Thus, the development of enzymatic biosensors requires a detailed study of enzyme kinetics. Parameters such as KM and Vmax are necessary to optimize the sensitivity and specificity of the biosensor.
View Article and Find Full Text PDFJ Mater Chem B
August 2025
Department of Chemistry, Catalysis Division, University of Isfahan, Isfahan, 81746-73441, Iran.
Coordination polymers (CPs) can be used as supporting materials for enzyme immobilization to overcome limitations arising from mass transfer barriers, active site blocking, and low enzyme loading, as previously demonstrated, employing metal-organic frameworks (MOFs). We report on a new composite containing glucose oxidase (GOD) and ZIF-7-III (Zn(bIm)), focusing on three aspects: formation, optimization of catalytic properties, and application. The immobilization of GOD on ZIF-7-III at room temperature was systematically studied by varying the amount of GOD and the reaction time.
View Article and Find Full Text PDFFood Chem
August 2025
Center of Excellence for Trace Analysis and Biosensor, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand; Center of Excellence for Innovation in Chemis
Nitrite (NO) is used in food production. High levels of NO intake pose health risks from carcinogenic nitrosamines. This research presents an electrochemical sensor that detects NO in ultra-processed foods and drinking water using a novel ultrafine carboxyl-functionalized carbon nanofiber (f-CNF) as an electrocatalyst.
View Article and Find Full Text PDFBiosensors (Basel)
July 2025
Dipartimento di Scienze di Base e Applicate, Università degli Studi della Basilicata, Via dell'Ateneo Lucano 10, 85100 Potenza, Italy.
A new approach in amperometric enzyme electrodes production based on all-electrochemically assisted procedures will be described. Enzyme (glucose oxidase) immobilization was performed by in situ co-crosslinking of enzyme molecules through electrophoretic protein deposition, assuring enzyme immobilization exclusively onto the transducer surface (Pt electrode). Analogously, the poor selectivity of the transducer was dramatically improved by the electrosynthesis of non-conducting polymers with built-in permselectivity, permitting the formation of a thin permselective film onto the transducer surface, able to reject common interferents usually found in real samples.
View Article and Find Full Text PDFACS Sens
August 2025
Neuroelectronics, Munich Institute of Biomedical Engineering, School of Computation, Information and Technology, Technical University of Munich, Hans-Piloty-Str. 1, 85748 Garching, Germany.
Understanding the functional connectivity and behavior of 3D cell cultures and organoids requires monitoring electrical activity across multiple planes. However, traditional planar microelectrode arrays (MEAs) are limited to surface recordings and struggle to capture signals from deeper layers. Additionally, current fabrication methods face challenges such as prolonged production times and limited design flexibility, which hinder the development of high-precision 3D electrode arrays and affect the quality of cell-electrode coupling.
View Article and Find Full Text PDF