Purpose: Orthopedic fractures are often fixed using metal implants. The correct positioning of cylindrical implants such as surgical screws, rods and guide wires is highly important. Intraoperative 3D imaging is often used to ensure proper implant placement. However, 3D image interaction is time-consuming and requires experience. We developed an automatic method that simplifies and accelerates location assessment of cylindrical implants in 3D images.
Methods: Our approach is composed of three major steps. At first, cylindrical characteristics are detected by analyzing image gradients in small image regions. Next, these characteristics are grouped in a cluster analysis. The clusters represent cylindrical implants and are used to initialize a cylinder-to-image registration. Finally, the two end points are optimized regarding image contrast along the cylinder axis.
Results: A total of 67 images containing 420 cylindrical implants were used for testing. Different anatomical regions (calcaneus, spine) and various image sources (two mobile devices, three reconstruction methods) were investigated. Depending on the evaluation set, the detection performance was between 91.7 and 96.1% true- positive rate with a false-positive rate between 2.0 and 3.2%. The end point distance errors ranged from [Formula: see text] to [Formula: see text] mm and the orientation errors from [Formula: see text] to [Formula: see text] degrees. The average computation time was less than 5 seconds.
Conclusions: An automatic method was developed and tested that obviates the need for 3D image interaction during intraoperative assessment of cylindrical orthopedic implants. The required time for working with the viewing software of cone-beam CT device is drastically reduced and leads to a shorter time under anesthesia for the patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11548-014-0998-8 | DOI Listing |
Pain Med Case Rep
August 2025
2Department of Neurosurgery, Allegheny Health Network, Neuroscience Institute, Pittsburgh, PA.
Background: Spinal cord stimulation (SCS) involves the placement of percutaneously placed cylindrical leads or surgically placed paddle leads to deliver electrical stimulation for pain relief. Although more invasive, paddle leads have been associated with less lead migration and revision. We performed a retrospective review of a prospective database of SCS paddle lead implants performed by a single neurosurgeon.
View Article and Find Full Text PDFMicromachines (Basel)
August 2025
Wuhan Neuracom Technology Development Co., Ltd., Wuhan 430074, China.
A 16-channel dual-sided flexible electrode based on a polyimide substrate was designed and fabricated using micro-electromechanical system (MEMS) technology. The electrode exhibited an average impedance of 5.9 kΩ at 1 kHz and a charge storage capacity (CSC) of 10.
View Article and Find Full Text PDFIndian J Ophthalmol
September 2025
Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, USA.
Purpose: To compare the effect of induced astigmatism and defocus on visual performance in patients with a dominant eye implanted with a dual-technology diffractive intraocular lens (IOL) or an enhanced monofocal IOL.
Methods: This non-randomized cohort study included 35 patients in each group. Group 1 underwent phacoemulsification and received the Tecnis Synergy IOL in the dominant eye.
Colloids Surf B Biointerfaces
December 2025
Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction, Tianjin 300041, China; International VIP Dental Clinic, Tianjin Stomatological Hospital, School of Medicine, Nankai University, Tianjin 300041, China. Electronic address:
This study addresses the challenges of slow and inadequate bone formation during the repair of bone defects by developing a novel porous biological scaffold with a vertical microchannel structure, loaded with the angiogenesis-promoting drug Deferoxamine (DFO). Utilizing 3D printing technology, cylindrical porous templates made of PLGA were manufactured, followed by the integration of Linear Wire Arrays (LWAs) technology and freeze-drying techniques to fabricate scaffolds with microchannels. The scaffolds' surface morphology was characterized using scanning electron microscopy, while their porosity, water absorption properties, and mechanical strength were quantified.
View Article and Find Full Text PDFSaudi Dent J
August 2025
Department of Prosthetic Dentistry, Faculty of Dentistry, Prince of Songkla University, Kanchanavanit, Hat Yai, Songkhla, Thailand.
Dental implants using digital technologies have become more popular for partial and fully edentulous patients. This in-vitro study aimed to compare the accuracy of one- and two-phase photogrammetry implant impression techniques. Six abutment-level implant analogs (screw-retained abutment diameter 4.
View Article and Find Full Text PDF