Article Abstract

A 16-channel dual-sided flexible electrode based on a polyimide substrate was designed and fabricated using micro-electromechanical system (MEMS) technology. The electrode exhibited an average impedance of 5.9 kΩ at 1 kHz and a charge storage capacity (CSC) of 10.63 mC/cm. Concurrently, a three-dimensional finite element model incorporating electrical stimulation and micromotion-induced damage was established. The simulation results demonstrated that the implantation trauma caused by the bilateral electrode was significantly lower compared with silicon-based and cylindrical electrodes, while also enabling directional stimulation. Furthermore, leveraging the design of experiments (DOE) methodology, a multivariate regression model was developed to investigate the influence of key stimulation parameters-namely, current amplitude, frequency, and pulse width-on the volume of tissue activated (VTA). The results indicated that the regression model provided accurate predictions of VTA (R = 0.912). Among the parameters, current amplitude and pulse width exerted a statistically significant influence on VTA size ( < 0.001), whereas the effect of frequency was comparatively minor ( = 0.387 > 0.05). This study presents the first successful fabrication and comprehensive dose-response analysis of a flexible bilateral DBS electrode. Its attributes of low implantation trauma, multi-channel capability, and directional stimulation offer a novel paradigm for precise neuromodulation. Additionally, the established stimulation parameter-VTA response model provides a robust theoretical foundation for optimizing therapeutic parameters in subsequent clinical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12388741PMC
http://dx.doi.org/10.3390/mi16080945DOI Listing

Publication Analysis

Top Keywords

implantation trauma
8
directional stimulation
8
regression model
8
current amplitude
8
stimulation
6
electrode
5
fabrication dose-response
4
dose-response simulation
4
simulation soft
4
soft dual-sided
4

Similar Publications

Engineering a cell-free bone regeneration platform using osteogenically primed MSC-EVs and nHAp-enriched IPN hydrogels.

Regen Med

September 2025

Symbiosis Centre for Stem Cell Research (SCSCR), Symbiosis School of Biological Sciences (SSBS), Symbiosis International, Deemed University, Lavale, Pune, India.

Aims: This study aimed to enhance the osteoinductive potential of mesenchymal stem cell-derived extracellular vesicles (MSC-EVs) by integrating them into a nano-hydroxyapatite (nHAp)-enriched hydrogel scaffold for bone regeneration applications.

Materials & Methods: EVs were isolated from naïve and osteogenically primed MSCs and characterized for morphology, cargo content, and cytocompatibility. Their uptake and osteoinductive activity were assessed using MC3T3 cells within a 3D interpenetrating network (IPN) hydrogel.

View Article and Find Full Text PDF

Background: Total hip arthroplasty (THA) is a common intervention for severe hip disorders. However, postoperative instability and dislocation continue to present significant challenges. To address these issues, dual mobility (DM) cups and large femoral heads (LFH) have been employed, each offering unique biomechanical benefits.

View Article and Find Full Text PDF

Introduction: Ipsilateral femoral neck and shaft fractures (IFN-SFs) caused by high-energy trauma pose a significant risk of complications related to bone healing. Prompt identification of fracture types and maintenance of fracture fixation stability can mitigate this risk. This study employed finite element analysis to evaluate biomechanical parameters for the stability of fixation in IFN-SFs and quantify differences in biomechanical stability among various fracture types.

View Article and Find Full Text PDF

Bioabsorbable fixation of a pediatric trochlear notch chondral injury.

J Surg Case Rep

September 2025

Department of Orthopaedics and Sports Medicine, University at Buffalo, 462 Grider Street, Buffalo, NY 14215, United States.

An 8-year-old girl fell onto her outstretched arm, sustaining proximal ulna and radial neck fractures. After closed reduction and casting in the emergency department, radiographs showed improved alignment but limited bony detail. A CT scan performed 3 days later demonstrated 18° apex-medial angulation of the radial neck, slight radiocapitellar subluxation, and subtle calcification near the trochlear notch, concerning intra-articular injury.

View Article and Find Full Text PDF

[Management of forearm shaft fractures : Challenges and solution approaches].

Unfallchirurgie (Heidelb)

September 2025

Klinik für Orthopädie und Unfallchirurgie, Klinikum Nürnberg, Paracelsus Medizinische Privatuniversität, Breslauer Straße 201, 90471, Nürnberg, Deutschland.

Forearm shaft fractures are the most common fractures of the upper extremity in young adults. By definition, these fractures are diaphyseal fractures; however, due to the complex functional unity formed by the forearm shaft during motion both bone forearm fractures are treated as intra-articular fractures [1, 3]. This is why the gold standard of treatment in adults is osteosynthesis.

View Article and Find Full Text PDF