Article Abstract

The goal of this study was to better understand how analytical permeability models based on scaffold architecture can facilitate a non-invasive technique to real time monitoring of pressure drop in bioreactors. In particular, we evaluated the permeability equations for electrospun and freeze dried scaffolds via pressure drop comparison in an axial-flow bioreactor using computational fluid dynamic (CFD) and experimentation. The polycaprolactone-cellulose acetate fibers obtained by co-axial electrospinning technique and Chitosan-Gelatin scaffolds prepared using freeze-drying techniques were utilized. Initially, the structural properties (fiber size, pore size and porosity) and mechanical properties (elastic modulus and Poisson's ratio) of scaffolds in phosphate buffered saline at 37 °C were evaluated. The CFD simulations were performed by coupling fluid flow, described by Brinkman equation, with structural mechanics using a moving mesh. The experimentally obtained pressure drop values for both 1 mm thick and 2 mm thick scaffolds agreed with simulation results. To evaluate the effect of permeability and elastic modulus on pressure drop, CFD predictions were extended to a broad range of permeabilities spanning synthetic scaffolds and tissues, elastic moduli, and Poisson's ratio. Results indicated an increase in pressure drop with increase in permeability. Scaffolds with higher elastic modulus performed better and the effect of Poisson's ratio was insignificant. Flow induced deformation was negligible in axial-flow bioreactor. In summary, scaffold permeabilities can be calculated using scaffold microarchitecture and can be used in non-invasive monitoring of tissue regeneration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-014-1009-5DOI Listing

Publication Analysis

Top Keywords

pressure drop
24
axial-flow bioreactor
12
elastic modulus
12
poisson's ratio
12
tissue regeneration
8
drop
6
scaffolds
6
pressure
5
modeling pressure
4
drop generalized
4

Similar Publications

Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.

Design: Cross-sectional pilot study.

Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.

View Article and Find Full Text PDF

Cerebral small-vessel disease (CSVD) is an important risk factor for cognitive impairment, which is a pressing health issue for the aging population worldwide. The complex relationship between vascular factors, such as blood pressure variability (BPV) and arteriosclerosis index (AI), and cognitive dysfunction in patients with CSVD is a hot research topic, and research in this area will help prevent and treat cognitive dysfunction in CSVD. This study aims to investigate the effects of diastolic BPV (DBPV) and AI on cognitive function in patients with CSVD.

View Article and Find Full Text PDF

Introduction: Pressure-based fractional flow reserve (FFR) and flow-based coronary flow reserve (CFR) assess the functional status of coronary artery disease (CAD) during cardiac catheterization. Complex hemodynamics may not be adequately explained by either pressure or flow alone. Consequently, pressure-drop coefficient (CDP, the ratio between pressure-drop across a stenosis and distal dynamic pressure) that combines both pressure and flow measurements has been developed to distinguish between epicardial stenosis (ES) and microvascular disease (MVD).

View Article and Find Full Text PDF

Cerebral autoregulation in orthostatic hypotension and falls among older adults: a community-based exploratory study.

Clin Auton Res

September 2025

Faculty of Medicine, Department of Medicine, Ageing and Age-Associated Disorders Research Group, Division of Geriatric Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia.

Background: Orthostatic hypotension (OH) is prevalent in older adults and is often associated with falls. However, the presence or absence of symptoms in OH may be mediated by cerebral autoregulation, which helps maintain cerebral perfusion during blood pressure fluctuations.

Methods: We recruited 40 older adults (aged ≥ 55 years) from the Malaysian Elders Longitudinal Research (MELoR) cohort.

View Article and Find Full Text PDF

The effect of shape and size of embolic agents on embolization phenomena has been discussed clinically for transcatheter arterial chemoembolization (TACE). We numerically discussed the unique embolization behavior of new deformable toroidal microparticles in blood vessels by computational fluid dynamics simulations. We employed an Eulerian-Eulerian (full Eulerian) fluid-structure interaction (FSI) method to analyze the flow and deformation behaviors of a deformable torus in a cylindrical pipe.

View Article and Find Full Text PDF