98%
921
2 minutes
20
Despite marvelous advances in repair for acute type A aortic dissection over past decades, it remains challenging to repair the aortic root when aortic dissection extended to the sinuses causes the fragile root because of its thinner layers, which are susceptible to suture trauma. Here, we describe a modified Florida sleeve technique to strengthen the weakened aortic root. After mobilization of the aortic root and the coronary arteries, a designed Dacron tube graft was wrapped outside the sinuses as neo-adventitia to reinforce the dissected weakened wall. During surgery for aortic dissection, our technique is easy and effective to reinforce a weakened root and avoid bleeding. Furthermore, this might be an alternative technique to restore and maintain the geometry of the aortic root.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3826657 | PMC |
http://dx.doi.org/10.1186/1749-8090-8-203 | DOI Listing |
Am J Emerg Med
September 2025
Department of Surgical Education, Orlando Regional Medical Center, Orlando, FL, USA; Department of Surgery, Division of Trauma and Surgical Critical Care, Orlando Regional Medical Center, Orlando, FL, USA. Electronic address:
Background: There is conflicting literature regarding mortality outcomes associated with REBOA usage in patients with severe thoracic or abdominal trauma. Our study aims to assess the benefits and negative implications of REBOA use in adult trauma patients in hemorrhagic shock with severe thoracic or abdominal injuries.
Methods: This retrospective cohort analysis utilized the American College of Surgeons Trauma Quality Improvement Program Participant Use File (ACS-TQIP-PUF) database from 2017 to 2023 to evaluate adult patients with severe isolated thoracic or abdominal trauma undergoing REBOA placement.
ESC Heart Fail
September 2025
Department of Cardiac-, Thoracic-, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Aims: Non-pharmacological therapies for acute decompensated heart failure (HF) and cardiogenic shock have evolved considerably in recent decades. Short-term mechanical circulatory support (MCS) devices can be used as circulatory backup. While nearly all available devices use continuous flow, evidence indicates that pulsatile flow can be more effective.
View Article and Find Full Text PDFJTCVS Open
August 2025
Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pa.
Objective: Valve selection in acute type A aortic dissection (ATAAD) requiring aortic root replacement is challenging given the clinical acuity, unknown patient preferences, risk of surgical bleeding, and limited life expectancy. We sought to identify long-term outcomes of mechanical versus bioprosthetic aortic root replacement in young patients with ATAAD.
Methods: Retrospective review of our institution's database of ATAAD was conducted to identify patients aged 65 years and younger who underwent mechanical Bentall (mech-Bentall) or bioprosthetic Bentall (bio-Bentall) for ATAAD from 2002 to 2022.
JTCVS Open
August 2025
Department of Cardiothoracic Surgery, Stanford University School of Medicine, Stanford, Calif.
Objectives: Loeys-Dietz syndrome comprises genetically discrete subtypes of varying clinical severity. This study integrates longitudinal Loeys-Dietz syndrome clinical outcomes after aortic root replacement with transcriptomic analysis of aortic smooth muscle cell dysregulation to investigate mechanisms governing this subtype-specific aortic vulnerability.
Methods: Single institutional experience with aortic root replacement for nondissected aneurysm in patients with Loeys-Dietz syndrome was reviewed for midterm survival and distal aortic events (subsequent aortic intervention, aneurysm, or dissection).
JTCVS Open
August 2025
Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn.
Objective: To evaluate the early postoperative morbidity, mortality, and prosthetic conduit function of patients who underwent aortic root replacement using a prefabricated bioprosthetic aortic valved conduit.
Methods: Single-center retrospective review of 124 consecutive adult patients who underwent aortic root replacement with a certified prefabricated bioprosthetic aortic valved conduit from 2021 to December 2023.
Results: Indications for operation were aortic aneurysms (n = 92), endocarditis (n = 12), deterioration of prior valve prosthesis (n = 13), and aortic dissection (n = 6).