Biomechanical comparison of three stand-alone lumbar cages--a three-dimensional finite element analysis.

BMC Musculoskelet Disord

Department of Mechanical Engineering, National Chiao Tung University, 1001 University Road, Hsinchu 30010, Taiwan.

Published: October 2013


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: For anterior lumbar interbody fusion (ALIF), stand-alone cages can be supplemented with vertebral plate, locking screws, or threaded cylinder to avoid the use of posterior fixation. Intuitively, the plate, screw, and cylinder aim to be embedded into the vertebral bodies to effectively immobilize the cage itself. The kinematic and mechanical effects of these integrated components on the lumbar construct have not been extensively studied. A nonlinearly lumbar finite-element model was developed and validated to investigate the biomechanical differences between three stand-alone (Latero, SynFix, and Stabilis) and SynCage-Open plus transpedicular fixation. All four cages were instrumented at the L3-4 level.

Methods: The lumbar models were subjected to the follower load along the lumbar column and the moment at the lumbar top to produce flexion (FL), extension (EX), left/right lateral bending (LLB, RLB), and left/right axial rotation (LAR, RAR). A 10 Nm moment was applied to obtain the six physiological motions in all models. The comparison indices included disc range of motion (ROM), facet contact force, and stresses of the annulus and implants.

Results: At the surgical level, the SynCage-open model supplemented with transpedicular fixation decreased ROM (>76%) greatly; while the SynFix model decreased ROM 56-72%, the Latero model decreased ROM 36-91%, in all motions as compared with the INT model. However, the Stabilis model decreased ROM slightly in extension (11%), lateral bending (21%), and axial rotation (34%). At the adjacent levels, there were no obvious differences in ROM and annulus stress among all instrumented models.

Conclusions: ALIF instrumentation with the Latero or SynFix cage provides an acceptable stability for clinical use without the requirement of additional posterior fixation. However, the Stabilis cage is not favored in extension and lateral bending because of insufficient stabilization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852219PMC
http://dx.doi.org/10.1186/1471-2474-14-281DOI Listing

Publication Analysis

Top Keywords

decreased rom
16
lateral bending
12
model decreased
12
three stand-alone
8
posterior fixation
8
latero synfix
8
transpedicular fixation
8
axial rotation
8
lumbar
7
model
6

Similar Publications

Introduction: This study examined the impacts of different negative pressure cupping therapies (PCT) on pain relief, functional recovery, and inflammatory regulation in delayed onset muscle soreness (DOMS) after high-intensity exercise, with the aim of clarifying the dose-effect relationship.

Methods: In this study, 55 healthy male participants aged 18-25 were selected and divided into 5 groups: the control group (CTR;  = 11) and NPCT groups at different levels (-25 kPa, -35 kPa, -45 kPa, and -55 kPa;  = 11 in each group). A high-intensity protocol, which included 6 sets of lunges, squats, and squat jumps, was adopted to induce DOMS in the quadriceps femoris.

View Article and Find Full Text PDF

Objective: To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.

Methods: CT data of the cervical spine (C-T) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C-C) was established using Mimics 10.

View Article and Find Full Text PDF

Background: Total knee arthroplasty (TKA) is one of the curative methods for patients with end-stage ankylosed knees. However, the existing methods are difficult to enable patients with hemophilic ankylosed knees to recover good functional activities.

Methods: Between January 2008 and December 2021, 22 male patients with ankylosed knees in the extended position due to hemophilia underwent TKA.

View Article and Find Full Text PDF

Passive neck stiffness and range of motion for males and females from early to late adulthood.

Spine J

August 2025

School of Electrical and Mechanical Engineering, The University of Adelaide, Level 7, Adelaide Health and Medical Sciences Building, North Terrace, Adelaide, SA, 5000. Electronic address:

Background Context: Understanding human passive neck range of motion (ROM) and stiffness, and their association with age and sex, can be beneficial for clinical assessment, surrogate and computational modelling.

Purpose: To assess passive head-neck ROM and stiffness, and to investigate association with age and sex, in flexion, extension, left and right lateral bending, and axial rotation.

Study Design/setting: In-vivo human participant testing.

View Article and Find Full Text PDF

: Total knee arthroplasty (TKA) is an effective solution for pain relief and functional recovery in patients with end-stage osteoarthritis. However, stiffness of the knee, limited range of motion, and weakened muscle strength are challenges of postoperative rehabilitation. This study investigated the effects of a pedaling-based progressive resistance training (PPRT) program on range of motion, muscle strength, physical function, and gait in patients who had undergone TKA.

View Article and Find Full Text PDF