Measurement of myocardial extracellular volume fraction by using equilibrium contrast-enhanced CT: validation against histologic findings.

Radiology

Centre for Medical Imaging and Institute of Cardiovascular Science, University College London, London, England; Heart Hospital, University College London Hospitals NHS Trust, 16-18 Westmoreland St, London W1G 8PH, England; Centre for Advanced Cardiovascular Imaging, NIHR Cardiovascular Biomedical Re

Published: November 2013


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To develop and validate equilibrium contrast material-enhanced computed tomography (CT) to measure myocardial extracellular volume (ECV) fraction by using a histologic reference standard and to compare equilibrium CT with equilibrium contrast-enhanced magnetic resonance (MR) imaging.

Materials And Methods: A local ethics committee approved the study, and all subjects gave fully informed written consent. An equilibrium CT protocol was developed using iohexol at 300 mg of iodine per milliliter (bolus of 1 mg per kilogram of body weight administered at a rate of 3 mL/sec, followed immediately by an infusion of 1.88 mL/kg per hour with CT imaging before and at 25 minutes after injection of bolus of contrast agent) and ECV within the myocardial septum measured using both equilibrium CT and equilibrium MR imaging in patients with severe aortic stenosis. Biopsy samples of the myocardial septum collected during valve replacement surgery were used for histologic quantification of extracellular fibrosis with picrosirius red staining. Equilibrium CT- and equilibrium MR imaging-derived ECV measurements were compared with histologically quantified fibrosis by using Pearson correlation. Agreement between equilibrium CT and equilibrium MR imaging was assessed by using Bland-Altman comparison.

Results: Twenty-three patients (16 male, seven female; mean age, 70.8 years; standard deviation, 8.3) were recruited. The mean percentage of histologic fibrosis was 18% (intersubject range, 5%-40%). There was a significant correlation between both equilibrium CT- and equilibrium MR imaging-derived ECV and percentage of histologic fibrosis (r = 0.71 [P < .001] and r = 0.84 [P < .0001], respectively). Equilibrium CT-derived ECV was significantly correlated to equilibrium MR imaging-derived ECV (r = 0.73).

Conclusion: ECV measured by using equilibrium CT in patients with aortic stenosis correlates with histologic quantification of myocardial fibrosis and with ECV derived by using equilibrium MR imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.13130130DOI Listing

Publication Analysis

Top Keywords

equilibrium
17
equilibrium equilibrium
12
equilibrium imaging
12
equilibrium imaging-derived
12
imaging-derived ecv
12
myocardial extracellular
8
extracellular volume
8
equilibrium contrast-enhanced
8
ecv
8
myocardial septum
8

Similar Publications

Rheumatoid arthritis (RA) is a chronic autoimmune disease in which dysregulated interferon regulatory factor 5 (IRF5) may amplify pro-inflammatory pathways; prior genetic studies of IRF5 single-nucleotide variants (SNVs) in RA are inconsistent across populations and have not included mestizo Mexicans or evaluated rs59110799 in RA. We aimed to test whether four IRF5 SNVs (rs2004640G/T, rs2070197T/C, rs10954213G/A, rs59110799G/T) confer susceptibility to RA in women from Central Mexico. In a case-control study of 239 women with RA and 231 female controls (all self-identified Mexican-Mestizos, ≥3 generations), genotyping was performed by real-time PCR with TaqMan® probes; 80% of samples were duplicated (100% concordance) and control genotypes conformed to Hardy-Weinberg equilibrium.

View Article and Find Full Text PDF

In this paper, we propose a general latent HIV infection model with general incidence and three distributed delays. We start with the analysis of the proposed model by establishing the positivity and boundedness of solutions and calculating basic reproduction number R0. Then, we show that the infection-free equilibrium is globally asymptotically stable when R0<1 (is globally attractive when R0=1), while the disease is uniformly persistent when R0>1.

View Article and Find Full Text PDF

We investigate species-rich mathematical models of ecosystems. While much of the existing literature focuses on the properties of equilibrium fixed-points, persistent dynamics (e.g.

View Article and Find Full Text PDF

The effect of shape and size of embolic agents on embolization phenomena has been discussed clinically for transcatheter arterial chemoembolization (TACE). We numerically discussed the unique embolization behavior of new deformable toroidal microparticles in blood vessels by computational fluid dynamics simulations. We employed an Eulerian-Eulerian (full Eulerian) fluid-structure interaction (FSI) method to analyze the flow and deformation behaviors of a deformable torus in a cylindrical pipe.

View Article and Find Full Text PDF

We introduce a novel method using a kilohertz (kHz) amplified 800 nm laser for the first experimental confinement of microparticles within a single beam. This study demonstrates that high-energy kHz pulses can confine 1-μm-radius polystyrene beads in water within ∼26 μm. This approach utilizes the unique properties of high-energy pulsed lasers, distinct from continuous-wave and megahertz pulsed lasers traditionally used in optical trapping.

View Article and Find Full Text PDF