A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A novel graphene-DNA biosensor for selective detection of mercury ions. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A novel electrochemical biosensor for sensitive and selective detection of mercury (II) ions (Hg²⁺) based on a DNA grafted graphene is proposed. Graphene oxide (GO) was reduced by dopamine, and then the single-strand probe DNA modified at the 5'-end with an alkylamino modifier (NH₂-ssDNA) was grafted on the reduced graphene oxide (RGO) surface via Michael addition reaction. In the presence of Hg²⁺, the target DNA with four thymine-thymine (T-T) mismatches would hybridize with the probe DNA on the glassy carbon electrode (GCE) through T-Hg²⁺-T coordination chemistry. The hybridization of the two oligonucleotides leads to the increase in the peak currents of [Ru(NH₃)₆]³⁺, which could be used for electrochemical sensing of Hg²⁺. The difference in the value of the peak currents of [Ru(NH₃)₆]³⁺ before and after DNA hybridization was linear with the concentration of Hg²⁺ in the range from 8.0×10⁻⁹ to 1.0×10⁻⁷ M with a linear coefficiency of 0.996. The detection limit was 5.0×10⁻⁹ M (S/N=3). The proposed electrochemical biosensor is rapid, convenient and low-cost for effective sensing of Hg²⁺. Particularly, the proposed method was applied successfully to the determination of Hg²⁺ in real environmental samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2013.04.013DOI Listing

Publication Analysis

Top Keywords

selective detection
8
detection mercury
8
mercury ions
8
electrochemical biosensor
8
graphene oxide
8
probe dna
8
peak currents
8
currents [runh₃₆]³⁺
8
sensing hg²⁺
8
hg²⁺
6

Similar Publications