Article Abstract

Background: Interfraction prostate motion must be compensated by increased safety margins. If filling status of rectum and bladder is constant, motion should be reduced. We attempted to reduce interfraction motion errors by proper patient instruction.

Method: In 38 patients pairs of radio-opaque fiducial markers were implanted prior to definitive radiotherapy. Patients were positioned either according to skin marks or infrared body marker. We measured prostate displacement, i.e. pelvic bones versus intraprostatic marker position, via ExacTrac (two orthogonal radiographies) in 1252 fractions. Systematic and random setup and displacement errors were determined and safety margins estimated.

Results: In our study interfraction prostate displacement is < 1 mm in RL direction, and < 2 mm in AP and SI direction. Systematic errors are slightly below random errors (< 1.5 mm). Positioning according skin marks results in higher inaccuracies of ±1.5 - 2 mm in RL and ±2 - 2.5 mm in AP/SI direction.

Conclusions: In case of appropriate patient instructions (constant organ filling) the positioning via bone fusion requires CTV-PTV margins of 2 mm in RL, 4 mm in AP, and 5 mm in SI direction. Studies without any description of patient instruction found much higher margins of > 1 cm in AP and SI direction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3447725PMC
http://dx.doi.org/10.1186/1748-717X-7-125DOI Listing

Publication Analysis

Top Keywords

prostate motion
8
interfraction prostate
8
safety margins
8
prostate displacement
8
appropriate patient
4
patient instructions
4
instructions reduce
4
prostate
4
reduce prostate
4
motion
4

Similar Publications

This narrative review analyzes current evidence comparing single-session and two-session approaches in Stereotactic Body Radiation Therapy (SBRT) and high-dose-rate (HDR) brachytherapy for localized prostate cancer. These ultra-hypofractionated strategies deliver high-precision ablative doses while minimizing exposure to normal tissues. SBRT regimens with fewer than five fractions show tumor control comparable to conventional treatments, offering reduced treatment burden and increased convenience.

View Article and Find Full Text PDF

The accuracy of surface imaging in detecting secondary patient motion caused by pitch and roll corrections in pelvic radiotherapy.

Phys Med

September 2025

Department of Biomedical Technology, Faculty of Medicine and Health Technology, Tampere University, Korkeakoulunkatu 8, 33720 Tampere, Finland; School of Electrical and Information Engineering, University of the Witwatersrand, Johannesburg, Jan Smutslaan 1, 2050 Braamfontein, South Africa.

Background And Objective: Correction of rotational setup errors by tilting the treatment couch improves target dose accuracy and prevents healthy tissue overdosage in external beam radiotherapy. However, couch tilts may cause secondary patient motion. This study aimed to quantify the secondary motion caused by pitch and roll corrections and to evaluate the feasibility of surface imaging for detecting the secondary motion in pelvic radiotherapy.

View Article and Find Full Text PDF

The Skp2-Cks1 protein-protein interaction (PPI) within the SCF ubiquitin ligase acts as a co-receptor for phosphorylated CDK inhibitors-most prominently p27-relieving CDK inhibition and advancing the cell cycle, a dependency accentuated in RB-pathway-defective cancers. Crystallographic and cryo-EM analyses delineate a composite pocket formed by the Skp2 leucine-rich-repeat groove and the phosphate-recognition site of Cks1; Cks1-centered open-closed motions further influence druggability. Using HTRF/TR-FRET and AlphaScreen biochemistry, alongside cell-based target-engagement readouts in some studies, three small-molecule classes have emerged that disrupt this PPI: 1,3-diphenyl-pyrazines and triazolo[1,5-a]pyrimidines (lead E35) with low-micromolar potency, and "Skp2E3LI" compounds with micromolar cellular activity.

View Article and Find Full Text PDF

Background: The limited workspace and strong magnetic field inside MRI challenge the design of the prostate puncture robot. Simplifying the robot's structure is crucial.

Methods: This paper proposes a parallel cable-driven (PCD) prostate puncture robot, and conducts a preliminary material design.

View Article and Find Full Text PDF

Purpose: To investigate the associations between different physical activity patterns, including "weekend warrior" (WW) (i.e. most weekly moderate-vigorous physical activity (MVPA) achieved over 1-2 days)) and regular (MVPA spread more evenly) patterns with the risk of incident cancers.

View Article and Find Full Text PDF