Accuracy and reliability of microbubble ultrasound measurements for the non-invasive assessment of hepatic fibrosis in chronic hepatitis C.

Hepatol Res

Section of Hepatology and Gastroenterology, Division of Diabetes Endocrinology and Metabolism Histopathology Unit, Division of Experimental Medicine, Department of Medicine, Imperial College London Department of Radiology, Imperial Healthcare NHS Trust, London Pfi

Published: May 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim:   Contrast-enhanced ultrasound can be used to assess liver disease severity non-invasively by observing intra- and extrahepatic hemodynamic changes. Transit times are calculated to include intra- and extrahepatic components (hepatic vein transit time, HVTT) or the intrahepatic component (hepatic transit time, HTT), but these have not been compared directly. We aimed to compare diagnostic accuracy of HVTT and HTT in gauging the severity of chronic hepatitis C (CHC) and to assess inter- and intra-observer reliability.

Methods:   Recorded ultrasound scans performed on 75 patients with biopsy-staged CHC, using the microbubble contrast agent Sonovue were analyzed.

Results:   Diagnostic accuracy of HTT and HVTT for diagnosis of cirrhosis was 0.78 and 0.71 (P = 0.24). Diagnostic accuracy of HTT and HVTT for diagnosis of fibrosis stage >2 was 0.76 and 0.72 (P = 0.23). Negative predictive value for cirrhosis using this cut-off was high for both techniques (HVTT, 88%; HTT, 92%), suggesting utility for exclusion of cirrhosis. Inter-observer reliability for HTT and HVTT were 0.92 and 0.94, respectively. Intra-observer reliability for HTT and HVTT were 0.98 and 0.99.

Conclusion:   In this cohort, reliability exceeded 90% while diagnostic accuracy was in keeping with previous studies of microbubble transit time analysis. Despite higher numerical diagnostic accuracy for HTT, no significant difference was demonstrated between the techniques, suggesting that both methods can be used reliably.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1872-034X.2011.00948.xDOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
20
htt hvtt
16
transit time
12
accuracy htt
12
chronic hepatitis
8
intra- extrahepatic
8
htt
8
hvtt diagnosis
8
reliability htt
8
hvtt
7

Similar Publications

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.

Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.

View Article and Find Full Text PDF

Background: Current scoring systems for hypertriglyceridaemia-induced acute pancreatitis (HTG-AP) severity are few and lack reliability. The present work focused on screening predicting factors for HTG-SAP, then constructing and validating the visualization model of HTG-AP severity by combining relevant metabolic indexes.

Methods: Between January 2020 and December 2024, retrospective clinical information for HTG-AP inpatients from Weifang People's Hospital was examined.

View Article and Find Full Text PDF

Obsessive-compulsive disorder (OCD) is a chronic and disabling condition affecting approximately 3.5% of the global population, with diagnosis on average delayed by 7.1 years or often confounded with other psychiatric disorders.

View Article and Find Full Text PDF

Background: Thyroid nodules (TNs) are frequent and often benign. Accurately differentiating between benign and malignant nodules is crucial for proper management. This research aims to use ultrasonography to examine TNs and identify possible risk factors in order to improve patient outcomes and diagnostic accuracy.

View Article and Find Full Text PDF