Effects of different implant-abutment connections on micromotion and stress distribution: prediction of microgap formation.

J Dent

Medical Implant Technology Group (MediTeg), Faculty of Biomedical Engineering & Health Sciences, Universiti Teknologi Malaysia, 81310 Johor Bahru, Malaysia.

Published: June 2012


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The aim of this study was to analyse micromotion and stress distribution at the connections of implants and four types of abutments: internal hexagonal, internal octagonal, internal conical and trilobe.

Methods: A three dimensional (3D) model of the left posterior mandible was reconstructed from medical datasets. Four dental implant systems were designed and analysed independently in a virtual simulation of a first molar replacement. Material properties, contact properties, physiological loading and boundary conditions were assigned to the 3D model. Statistical analysis was performed using one-way analysis of variance (ANOVA) with a 95% confidence interval and Tukey's Honestly Significant Difference (HSD) multiple comparison test.

Results: The internal hexagonal and octagonal abutments produced similar patterns of micromotion and stress distribution due to their regular polygonal design. The internal conical abutment produced the highest magnitude of micromotion, whereas the trilobe connection showed the lowest magnitude of micromotion due to its polygonal profile.

Conclusions: Non-cylindrical abutments provided a stable locking mechanism that reduced micromotion, and therefore reduced the occurrence of microgaps. However, stress tends to concentrate at the vertices of abutments, which could lead to microfractures and subsequent microgap formation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2012.02.009DOI Listing

Publication Analysis

Top Keywords

micromotion stress
12
stress distribution
12
microgap formation
8
internal hexagonal
8
internal conical
8
magnitude micromotion
8
micromotion
6
internal
5
effects implant-abutment
4
implant-abutment connections
4

Similar Publications

Although metal blocks have been widely used for reconstructing uncontained tibial bone defects, the influence of their elastic modulus on the stability of tibial prosthesis fixation remains unclear. Based on this, a finite element model incorporating constrained condylar knee (CCK) prosthesis, tibia, and metal block was established. Considering the influence of the post-restraint structure of the prosthesis, the effects of variations in the elastic modulus of the block on the von Mises stress distribution in the tibia and the block, as well as on the micromotion at the bone-prosthesis fixation interface, were investigated.

View Article and Find Full Text PDF

Background: Research on the ideal fixation position for plates in medial opening-wedge high tibial osteotomy (MOWHTO) directly applicable in clinical settings is scarce. Therefore, this study aimed to evaluate the biomechanical effects of different plate positions in MOWHTO through finite element analysis (FEA) to explore a potentially optimal plate position.

Methods: Utilizing the computed tomography images of a 67-year-old man, a 3-dimensional model of the knee, along with an implant (TomoFix standard plate and screws), was created to simulate a virtual MOWHTO with a 10° medial opening gap.

View Article and Find Full Text PDF

Acoustic emission-based diagnostic tool for temporomandibular joint implant fixation screw loosening.

J Mech Behav Biomed Mater

November 2025

Department of Biomedical Engineering, UIC, United States; UIC Scientific Instrument Shop, UIC, United States; Department of Restorative Dentistry, College of Dentistry, UIC, United States. Electronic address:

Alloplastic temporomandibular joint replacement (TMJR) implants have become an acceptable clinical solution for end-stage temporomandibular joint (TMJ) pathology. However, early screw fixation loosening can be a concern. Acoustic emission (AE) has been reported to successfully detect the early deformation of hip implants.

View Article and Find Full Text PDF

This study establishes a standardized geometric model of the tibiotalar joint based on anatomical morphology and validates its statistical representativeness. Using this model, a novel fusion implant was developed and evaluated for its biomechanical performance through nonlinear finite element (FE) analysis compared to traditional fixation methods. A morphological database of the tibiotalar joint was built using 30 computed tomography (CT) scans to determine key dimensional parameters, and a novel fusion implant was designed to match the joint's natural curvature.

View Article and Find Full Text PDF

Fixation of surface microarchitecture for interbody fusion devices under spondylolisthesis loading conditions.

Clin Biomech (Bristol)

August 2025

Additive Implants Inc., 3101 East Shea Boulevard, Phoenix, AZ 85028, USA. Electronic address:

Background: Initial stability between a lumbar fusion cage and the vertebral endplates, particularly under the adverse loading conditions characteristic of spondylolisthesis, is vital for osseointegration and fusion. The aim of this study was to compare fixation strength and stability of surface microarchitecture designs of interbody fusion devices under shear loading in synthetic bone as a function of bone density and sagittal inclination.

Methods: Two surface design parameters were evaluated, serration height and pattern (1 mm-triangle 2 mm-triangle, and 2 mm-wedge serration patterns), under 30° and 45° of sagittal inclination.

View Article and Find Full Text PDF