A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Personalised modified osteotomy using computer-aided design-rapid prototyping to correct thoracic deformities. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The correction of severe thoracic deformities is challenging. However, the usual imaging modalities are not sufficient for performing the surgery. Our objective was to describe the procedure and results of posterior modified wedge osteotomy aided by the techniques of computer-aided design-rapid prototyping (CAD-RP) to correct thoracic deformities. Twenty-one patients with thoracic deformities (eight males; 13 females) formed the study group. All patients underwent computed tomography (CT) scanning and CAD-RP, and a model of thoracic deformities and navigation templates of pedicles were created for each patient and used to analyse the spinal deformities and serve as anatomical reference. Aided by these models, personalised modified wedge osteotomy combining the eggshell technique and posterior vertebral column resection was performed. Using CAD-RP improved the safety and accuracy of surgery and screw placement in the 21 patients in whom 41 vertebrae were removed and 216 pedicle screws were placed. The average operation time was 260 (200-420) min, with an average blood loss of 1,900 ml (range 800-3560 ml). The percentage of deformity correction was 56.3% (from 72.1° to 31.5°) in the coronal plane and 60.4% (from 81.6° to 32.3°) in the sagittal plane. No patient had serious complications or implant failure. Personalised single-stage posterior modified wedge osteotomy is an effective procedure for treating thoracic deformities. Using CAD-RP and the RP models have significant benefits for personalised surgical treatment of complex thoracic deformities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3224619PMC
http://dx.doi.org/10.1007/s00264-010-1155-9DOI Listing

Publication Analysis

Top Keywords

thoracic deformities
28
modified wedge
12
wedge osteotomy
12
personalised modified
8
computer-aided design-rapid
8
design-rapid prototyping
8
correct thoracic
8
deformities
8
posterior modified
8
thoracic
7

Similar Publications