[Finite element study of maxillary Le Fort-I osteotomy with rigid internal fixation].

Zhonghua Zheng Xing Wai Ke Za Zhi

The Department of Stomatology, the General Hospital, Tianjin Medical University, Tianjin 300052, China.

Published: May 2010


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To study the biomechanical characteristic of maxillary Le fort- I osteotomy with rigid internal fixation (RIF) , so as to choose best fixation method.

Methods: The 3-dimensional finite element models of maxillary Le Fort-I osteotomy with 9 kinds of RIF methods were established. Then the models were divided into three groups to calculate the stress distribution of the maxilla and the displacement of bone segment under 3 kinds of occlusion condition. The fixation stability of the different RIF methods was evaluated.

Results: Under the incisor occlusion condition, the stress of the cranio maxillary complex transmits mainly along the nasal-maxillary buttress. Under the premolar and molar occlusion condition, the stress transmits along the alveolar process first, then turns to the nasal-maxillary and zygomatic-maxillary buttress. The focused stress position of the internal fixation system is at the connection between the screws and the plate and at the plate near the osteotomy line. Under the premolar occlusion condition, the displacement of bone segment with different RIF methods was (in a decreasing order) 0.396509 mm (with bio-absorbable plate), 0.148393 mm (with micro-plate ), 0.078436 mm (with mini-plate) in group 1; 0.188791 mm (fixing at the nasal-maxillary buttress), 0.121718 mm (fixing at the zygomatic-maxillary buttress), 0.078436 mm (fixing at the both buttress) in group 2; 0.091023 mm (with straight plate), 0.078436 mm (with L shape plate), 0.072450 mm (with Y shape plate), 0.065617 mm (with T shape plate) in group 3.

Conclusions: The fixation stability of using the bio-absorbable plate in Le Fort-I osteotomy is less stable than using the titanium plate. Fixing at the zygomatic-maxillary buttress is more stable than at the naso-maxillary buttress. The fixation stability is different by using different shapes of plates.

Download full-text PDF

Source

Publication Analysis

Top Keywords

occlusion condition
16
fort-i osteotomy
12
rif methods
12
fixation stability
12
zygomatic-maxillary buttress
12
shape plate
12
plate
9
maxillary fort-i
8
osteotomy rigid
8
rigid internal
8

Similar Publications

Background: Lower extremity arterial disease is a prevalent vascular condition leading to ischemic symptoms and increased risk of cardiovascular events. Drug-eluting stents have improved outcomes by reducing restenosis, with sirolimus emerging as a promising alternative to paclitaxel due to its safer profile. This study evaluates the efficacy and safety of novel polymer-free Amphilimus formulation (Sirolimus + fatty acid) eluting self-expanding stent in the treatment of femoropopliteal disease in a real-world population.

View Article and Find Full Text PDF

Transposing intensive care innovation from modern warfare to other resource-limited settings.

Eur J Trauma Emerg Surg

September 2025

French Military Medical Service Academy - École du Val-de-Grâce, Paris, France.

Background: Delivering intensive care in conflict zones and other resource-limited settings presents unique clinical, logistical, and ethical challenges. These contexts, characterized by disrupted infrastructure, limited personnel, and prolonged field care, require adapted strategies to ensure critical care delivery under resource-limited settings.

Objective: This scoping review aims to identify and characterize medical innovations developed or implemented in recent conflicts that may be relevant and transposable to intensive care units operating in other resource-limited settings.

View Article and Find Full Text PDF

Intracranial Rescue Stenting in Pediatric Focal Cerebral Arteriopathy.

Clin Neuroradiol

September 2025

Department of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Background: Pediatric acute ischemic stroke is a rare yet severe condition with multifactorial etiology, often associated with vasculopathies. Endovascular intervention in children with focal cerebral arteriopathy is seldom reported.

Purpose: Our aim was to report feasibility of intracranial rescue stenting for the management of pediatric focal cerebral arteriopathy with flow-limiting stenosis.

View Article and Find Full Text PDF

Introduction: Age related hearing loss is in the top ten contributors to the global burden of disease and one of the largest modifiable risk factors for age-related dementia. However, awareness of the consequences of untreated hearing loss is poor and many adults do not seek hearing assessment. Despite World Health Organisation recommendations, no EU country currently has a national adult screening programme.

View Article and Find Full Text PDF

Background: Ischemic stroke (IS) is a common neurological disease with a significant financial burden but lacks effective drugs. This study sought to explore the mechanisms underlying MAP kinase-interacting serine/threonine-protein kinase 2 (MKNK2), a gene enriched in the hypoxia-inducible factor-1 (HIF-1) signaling, in IS-related neurological injury.

Methods: Middle cerebral artery occlusion/reperfusion (MCAO/R) and oxygen-glucose deprivation/reoxygenation (OGD/R) models were used in vivo and in vitro.

View Article and Find Full Text PDF