Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: This study aimed to investigate the diagnostic value of computed tomography virtual intravascular endoscopy (VIE) in the follow-up of patients with abdominal aortic aneurysm (AAA) treated with fenestrated stent grafts.

Methods: A total of 19 patients (17 males and 2 females; mean age: 75 years) with AAA undergoing fenestrated stent grafts were retrospectively studied. Pre- and post-fenestration computed tomography data were reconstructed for the generation of VIE images of aortic ostia and fenestrated stents and compared with two-dimensional axial and multiplanar reformation (MPR) images. Serum creatinine was measured pre and post fenestration to evaluate the renal function.

Results: The mean intra-aortic length measured by VIE, two-dimensional axial and MPR were 4.7, 4.4 and 4.6 mm, respectively, for the right renal stent; 5.0, 4.9 and 5.0 mm, respectively, for the left renal stent; and 5.9, 6.0 and 6.0 mm, respectively, for the superior mesenteric artery stent. Comparisons of these measurements did not show significant difference (P > 0.05). The mean diameters of renal artery ostia measured on VIE visualization pre and post fenestration were 9.2 x 8.3 and 10 x 8.9 mm for the right renal ostium; 8.3 x 7.1 and 9.9 x 8.9 mm for the left renal ostium, with significant changes observed (P < 0.01). No renal dysfunction was observed in this group.

Conclusion: VIE is a valuable visualization tool in the follow-up of fenestrated stent graft repair of AAA by providing intraluminal appearance of fenestrated stents and measuring the length of stent protrusion.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1445-2197.2009.05112.xDOI Listing

Publication Analysis

Top Keywords

fenestrated stent
16
computed tomography
12
tomography virtual
8
virtual intravascular
8
intravascular endoscopy
8
stent
8
stent graft
8
graft repair
8
abdominal aortic
8
fenestrated stents
8

Similar Publications

Thoracic endovascular aortic repair (TEVAR) involving the left subclavian artery (Ishimaru zone 2) presents technical challenges. This multicentre study evaluates the Ankura thoracic stent graft with in-situ fenestration using a dedicated needle system (Lifetech, Shenzhen, China) for various thoracic aortic pathologies. Between January 2020 and December 2025, 59 patients from three tertiary centres underwent in-situ fenestration TEVAR (if-TEVAR) for thoracoabdominal aortic pathologies.

View Article and Find Full Text PDF

A 65-year-old man presented with Stanford type B aortic dissection complicated by rupture of the distal aortic arch, originating from the false lumen. Due to the short distance between the supra-aortic branches, the lack of peripheral access from malperfusion, and the invasiveness of combined arch and descending aortic replacement via left thoracotomy, emergency total arch replacement with a frozen elephant trunk was chosen to close the primary entry and control the rupture. However, intraoperative deployment of the prosthesis into the false lumen was suspected due to increasing bleeding and transesophageal echocardiographic findings.

View Article and Find Full Text PDF

Superior vena cava (SVC) occlusion in hemodialysis patients presents significant therapeutic challenges, particularly when complicated by stent migration. Sharp recanalization may serve as a salvage intervention for refractory cases though high-risk. Here, we present a 72-year-old male with stent migration-induced recurrent SVC syndrome.

View Article and Find Full Text PDF

Background: Vertebrobasilar junction (VBJ) aneurysms are frequently associated with basilar artery variations like fenestration or hypoplasia, altering hemodynamics. An interrupted aortic arch (IAA), a rare congenital malformation, may contribute to intracranial aneurysms via vascular wall defects, hemodynamic stress, and compensatory hypertension. Coexistence of IAA with cerebrovascular anomalies and VBJ aneurysms is exceptionally rare, with no prior documented cases.

View Article and Find Full Text PDF

Impact of a new Stepped Balloon for Bridging Stent implantation on Procedural Time and Radiation Exposure in Fenestrated Endovascular Aortic Repair.

J Vasc Surg

August 2025

Aortic Center, Department of Vascular Surgery, Hôpital Marie Lannelongue, Groupe hospitalier Paris Saint Joseph, INSERM UMR_S 999, Université Paris-Saclay, Paris, France. Electronic address:

Objective: To evaluate the impact of a new dedicated stepped balloon mounted bridging stent (BS) on procedural time, radiation exposure, and early technical outcomes in patients undergoing Fenestrated Endovascular Aortic Repair (FEVAR).

Methods: A retrospective study was conducted on patients treated with four-fenestration FEVAR at a high-volume aortic center between March 2020 and March 2025. Patients were categorized into three groups: Standard balloon BS (Begraft, BG, Bentley) and renal access with preloaded renal catheters; Standard balloon BS (BG) and renal access with steerable sheaths; and stepped balloon BS (BeFlared, BF, Bentley) and renal access with steerable sheaths.

View Article and Find Full Text PDF