Article Abstract

Background: The purposes of this study were to determine the validity and reliability of high resolution accelerometers (HRA) relative to VO(2) and speed, and compare putative differences in HRA signal between trained (T) and untrained (UT) runners during treadmill locomotion.

Methodology: Runners performed 2 incremental VO(2max) trials while wearing HRA. RMS of high frequency signal from three axes (VT, ML, AP) and the Euclidean resultant (RES) were compared to VO(2) to determine validity and reliability. Additionally, axial rms relative to speed, and ratio of axial accelerations to RES were compared between T and UT to determine if differences in running mechanics could be identified between the two groups.

Principal Findings: Regression of RES was strongly related to VO(2), but T was different than UT (r = 0.96 vs 0.92; p<.001) for walking and running. During walking, only the ratio of ML and AP to RES were different between groups. For running, nearly all acceleration parameters were lower for T than UT, the exception being ratio of VT to RES, which was higher in T than UT. All of these differences during running were despite higher VO(2), O(2) cost, and lower RER in T vs UT, which resulted in no significant difference in energy expenditure between groups.

Conclusions/signficance: These results indicate that HRA can accurately and reliably estimate VO(2) during treadmill locomotion, but differences exist between T and UT that should be considered when estimating energy expenditure. Differences in running mechanics between T and UT were identified, yet the importance of these differences remains to be determined.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2752199PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0007355PLOS

Publication Analysis

Top Keywords

high resolution
8
running mechanics
8
untrained runners
8
determine validity
8
validity reliability
8
res compared
8
resolution mems
4
mems accelerometers
4
accelerometers estimate
4
vo2
4

Similar Publications

In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.

View Article and Find Full Text PDF

Swept Source Optical Coherence Tomography Imaging of the Optic Pit Complex.

Retina

September 2025

From the Vitreous, Retina, Macula Consultants of New York, New York, NY.

Purpose: To reassess the anatomic basis of optic disc pit maculopathy (OPM) using swept-source optical coherence tomography (SS-OCT) and to characterize the broader structural abnormalities comprising the optic pit complex.

Methods: Sixteen patients with OPM were imaged using a high-resolution SS-OCT system (DREAM OCT). Cross-sectional and volume-rendered scans were analyzed for lamina cribrosa defects, intraneural cavitations, and pathways for fluid entry into or beneath the retina.

View Article and Find Full Text PDF

The lateral prefrontal cortex (LPFC) serves as a critical hub for higher-order cognitive and executive functions in the human brain, coordinating brain networks whose disruption has been implicated in many neurological and psychiatric disorders. While transcranial brain stimulation treatments often target the LPFC, our current understanding of connectivity profiles guiding these interventions based on electrophysiology remains limited. Here, we present a high-resolution probabilistic map of bidirectional effective connectivity between the LPFC and widespread cortical and subcortical regions.

View Article and Find Full Text PDF

PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.

View Article and Find Full Text PDF

Two-dimensional (2D) materials offer a valuable platform for manipulating and studying chemical reactions at the atomic level, owing to the ease of controlling their microscopic structure at the nanometer scale. While extensive research has been conducted on the structure-dependent chemical activity of 2D materials, the influence of structural transformation during the reaction has remained largely unexplored. In this work, we report the layer-dependent chemical reactivity of MoS during a nitridation atomic substitution reaction and attribute it to the rearrangement of Mo atoms.

View Article and Find Full Text PDF