98%
921
2 minutes
20
Background: The purposes of this study were to determine the validity and reliability of high resolution accelerometers (HRA) relative to VO(2) and speed, and compare putative differences in HRA signal between trained (T) and untrained (UT) runners during treadmill locomotion.
Methodology: Runners performed 2 incremental VO(2max) trials while wearing HRA. RMS of high frequency signal from three axes (VT, ML, AP) and the Euclidean resultant (RES) were compared to VO(2) to determine validity and reliability. Additionally, axial rms relative to speed, and ratio of axial accelerations to RES were compared between T and UT to determine if differences in running mechanics could be identified between the two groups.
Principal Findings: Regression of RES was strongly related to VO(2), but T was different than UT (r = 0.96 vs 0.92; p<.001) for walking and running. During walking, only the ratio of ML and AP to RES were different between groups. For running, nearly all acceleration parameters were lower for T than UT, the exception being ratio of VT to RES, which was higher in T than UT. All of these differences during running were despite higher VO(2), O(2) cost, and lower RER in T vs UT, which resulted in no significant difference in energy expenditure between groups.
Conclusions/signficance: These results indicate that HRA can accurately and reliably estimate VO(2) during treadmill locomotion, but differences exist between T and UT that should be considered when estimating energy expenditure. Differences in running mechanics between T and UT were identified, yet the importance of these differences remains to be determined.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2752199 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0007355 | PLOS |
J Am Soc Mass Spectrom
September 2025
Chemistry Department, Indiana University, 800 E Kirkwood Ave, Bloomington, Indiana 47405.
In charge detection mass spectrometry (CD-MS) ions are trapped in an electrostatic linear ion trap (ELIT) where they oscillate back and forth through a conducting cylinder. The oscillating ions induce a periodic charge separation that is detected by a charge sensitive amplifier (CSA) connected to the cylinder. The resulting time domain signal is analyzed using short-time Fourier transforms to give the mass-to-charge ratio and charge for each ion, which are then multiplied to give the mass.
View Article and Find Full Text PDFRetina
September 2025
From the Vitreous, Retina, Macula Consultants of New York, New York, NY.
Purpose: To reassess the anatomic basis of optic disc pit maculopathy (OPM) using swept-source optical coherence tomography (SS-OCT) and to characterize the broader structural abnormalities comprising the optic pit complex.
Methods: Sixteen patients with OPM were imaged using a high-resolution SS-OCT system (DREAM OCT). Cross-sectional and volume-rendered scans were analyzed for lamina cribrosa defects, intraneural cavitations, and pathways for fluid entry into or beneath the retina.
Brain
September 2025
Aix Marseille Univ, INSERM, INS, Inst Neurosci Syst, 13005 Marseille, France.
The lateral prefrontal cortex (LPFC) serves as a critical hub for higher-order cognitive and executive functions in the human brain, coordinating brain networks whose disruption has been implicated in many neurological and psychiatric disorders. While transcranial brain stimulation treatments often target the LPFC, our current understanding of connectivity profiles guiding these interventions based on electrophysiology remains limited. Here, we present a high-resolution probabilistic map of bidirectional effective connectivity between the LPFC and widespread cortical and subcortical regions.
View Article and Find Full Text PDFEur J Ophthalmol
September 2025
vEyes NPO, vEyes Lab, Milo, Italy.
PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.
View Article and Find Full Text PDFJ Am Chem Soc
September 2025
Department of Chemistry, Boston University, Boston, Massachusetts 02215, United States.
Two-dimensional (2D) materials offer a valuable platform for manipulating and studying chemical reactions at the atomic level, owing to the ease of controlling their microscopic structure at the nanometer scale. While extensive research has been conducted on the structure-dependent chemical activity of 2D materials, the influence of structural transformation during the reaction has remained largely unexplored. In this work, we report the layer-dependent chemical reactivity of MoS during a nitridation atomic substitution reaction and attribute it to the rearrangement of Mo atoms.
View Article and Find Full Text PDF