98%
921
2 minutes
20
On the move: Electrochemistry has been used to detect and monitor the motion of a single 330 microm sphere in both time and space (see picture). The motion was recorded simultaneously by video and chronoamperometry, which showed an excellent correlation. The ability to fabricate electrode arrays capable of spatial resolution at the sub-micrometer scale opens the possibility of using this technique to monitor considerably smaller particles.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/anie.200805428 | DOI Listing |
J Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFCrit Care
September 2025
Department of Pediatrics I, University Hospital Essen, University of Duisburg-Essen, Hufelandstr, 55, Essen, 45239, Germany.
Background: Gender disparities persist in medical research. This study assessed gender representation trends in first and senior authorships in the five highest-ranked critical care journals (by impact factor) over a 20-year period.
Methods: We analyzed author gender distribution from 2005 to 2024.
Catheter Cardiovasc Interv
September 2025
Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background: Patent foramen ovale (PFO) has been identified as a potential risk factor for cryptogenic stroke (CS). Although transesophageal echocardiography (TEE) is considered the gold standard for PFO detection, false-negative results remain a clinical concern, particularly in CS patients with high suspicion of PFO-related etiology.
Aims: To evaluate the clinical utility of transcatheter PFO exploration (TPFOE) in CS patients with negative TEE findings but high suspicion of PFO-related etiology.
BMC Public Health
September 2025
Department of Sociology and Work Science, University of Gothenburg, Gothenburg, Sweden.
Background: Mental health problems are common in the working-age population. More knowledge is needed on how to support work participation and reduce sickness absence. The objective of the study was to estimate the distribution of mental well-being and work capacity in women and men in a working population and assess the association between mental well-being and work capacity, while adjusting for sociodemographic characteristics, health status, and working positions.
View Article and Find Full Text PDFBMC Ecol Evol
September 2025
Lehrstuhl für Zoologie, TUM School of Life Sciences, Technical University of Munich, Liesel-Beckmann Strasse 4, Freising, 85354, Germany.
Accurate three-dimensional localisation of ultrasonic bat calls is essential for advancing behavioural and ecological research. I present a comprehensive, open-source simulation framework-Array WAH-for designing, evaluating, and optimising microphone arrays tailored to bioacoustic tracking. The tool incorporates biologically realistic signal generation, frequency-dependent propagation, and advanced Time Difference of Arrival (TDoA) localisation algorithms, enabling precise quantification of both positional and angular accuracy.
View Article and Find Full Text PDF