Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Label-free relative quantitative proteomics is a powerful tool for the survey of protein level changes between two biological samples. We have developed and applied an algorithm using chromatographic alignment of microLC-MS runs to improve the detection of differences between complex protein mixtures. We demonstrate the performance of our software by finding differences in E. coli protein abundance upon induction of the lac operon genes using isopropyl beta-D-thiogalactopyranoside. The use of our alignment gave a 4-fold decrease in mean relative retention time error and a 6-fold increase in the number of statistically significant differences between samples. Using a conservative threshold, we have identified 5290 total microLC-MS regions that have a different abundance between these samples. Of the detected difference regions, only 23% were mapped to MS/MS peptide identifications. We detected 74 proteins that had a greater relative abundance in the induced sample and 21 with a greater abundance in the uninduced sample. We have developed an effective tool for the label-free detection of differences between samples and demonstrate an increased sensitivity following chromatographic alignment.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac701649eDOI Listing

Publication Analysis

Top Keywords

chromatographic alignment
12
detection differences
8
differences samples
8
label-free comparative
4
comparative analysis
4
analysis proteomics
4
proteomics mixtures
4
mixtures chromatographic
4
alignment
4
alignment high-resolution
4

Similar Publications

Nifurtimox (NFX) is a chiral drug used for the treatment of Chagas Disease. Little attention has been paid to the enantioselective properties of chiral drugs used for neglected tropical diseases, highlighting the need for further studies in this area. In this work, the enantioselective properties of NFX were carefully investigated by HPLC using different chiral stationary phases (CSPs) and chromatographic modes.

View Article and Find Full Text PDF

The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use M10 guideline provides a global framework for bioanalytical method validation in studies intended for regulatory submission. While its structure ensures consistency and data reliability, the guideline also acknowledges that not all studies require the same level of validation. This paper examines where full compliance is essential and where scientific judgment allows for leaner, context-driven validation, such as in early-stage development, for additional matrices, metabolites, nonstandard biological matrices or studies intended for internal decision-making.

View Article and Find Full Text PDF

Liquid chromatography has advanced considerably since its introduction in the 1970s, with reversed-phase liquid chromatography (RPLC) becoming the dominant technique for separating non-volatile molecules. A key strategy for optimising separation conditions is the modelling of chromatographic retention from experimental data. Traditionally, this is achieved by fitting model parameters for each solute, resulting in individual solute models (ISMs).

View Article and Find Full Text PDF

Food composition has been traditionally defined by 35-160 chemical components with established nutritional significance for human health. Modern omics technologies have revealed that the chemical complexity of food is far greater, offering the potential to deepen our understanding of food composition to more precisely inform data-driven solutions across food systems. However, challenges in generating comparable omics data have limited the utility of omics technologies at the scale required to expand food composition databases.

View Article and Find Full Text PDF

To enhance greenness and efficiency in qualitative analysis by a single marker (QAMS), this study proposed an improved method integrating environmental impact as a critical method attribute (CMA) and chromatographic column specifications as a critical method parameter (CMP). Using one-factor-at-a-time and split-plot designs, relationships between CMPs and CMAs were evaluated. The method operable design region (MODR) incorporating column variability was determined Monte Carlo risk-based quantification.

View Article and Find Full Text PDF