The aim of this study was to determine the level of two major mite allergens Dermatophagoides pteronyssinus (Der p 1) and Dermatophagoides farinae (Der f 1) in 30 urban homes in Zagreb, Croatia, using the enzyme immunoassay with two monoclonal antibodies which has been established as the reference method for indoor allergen analysis. Dust samples were taken by vacuuming a carpeted area and collected on cellulose filters. The ranges of Der p 1 and Der f 1 were (0.1-12.5) microg g-1 (median 0.32 microg g-1) and (0.1-31.2) microg g-1 (median 0.35 microg g-1), respectively. Der p 1 and Der f 1 (>2 microg g-1) associated with increased risk of sensitization to mite allergens were found in approximately 16% homes for each allergen. The sum of allergen (Der p 1 + Der f 1) exceeded the lower threshold in 27% of homes. Analytical evaluation of the ELISA assay showed satisfactory results for precision (intra-assay CV <6.9%, inter-assay CV<13.3%), accuracy (91% to 93%), and sensitivity (2 ng mL-1). The ELISA assay for the measurement of dust mite allergens demonstrated very good analytical characteristics for routine laboratory use, and will provide the essential basis for our future studies of various indoor allergens.

Download full-text PDF

Source
http://dx.doi.org/10.2478/v10004-007-0034-2DOI Listing

Publication Analysis

Top Keywords

microg g-1
20
mite allergens
12
der der
12
enzyme immunoassay
8
der
8
g-1 median
8
microg
5
g-1
5
determination mite
4
allergens house
4

Similar Publications

Totally 128 surficial sediments samples were collected from the coastal wetlands, northeastern Hainan Island and analyzed for their concentrations of 14 elements including Al2O3, Fe2O3, MnO, Cu, Ni, Sr, Zn, V, Pb, Cr, Zr, As, Cd and Hg, TOC and grain sizes. The mean concentrations of trace metals V, Cr, Ni, Cu, Zn, As, Pb, Cd and Hg were (40.13 +/- 32.

View Article and Find Full Text PDF

In order to investigate the feasibility of deep denitrification and simultaneous removing phthalate esters (PAEs) in the process of reclaimed water treatment uses three-dimensional biofilm-electrode reactor coupled with sulfur autotrophic deep denitrification technology (3BER-S), the technological characteristics and mechanisms were analyzed based on determining the static adsorption capacity of biofilm cultured active carbon fillers in 3BER-S reactor together with the operation results of dynamic denitrification and simultaneous PAEs removing. The results showed that the average adsorption rates of DBP, DEHP were 85.84% and 97.

View Article and Find Full Text PDF

The aim of this study was to elucidate the scientific connotation of Bombyx Batryticatus processing with wheat bran under high temperature. The contents of soluble protein extracted from Bombyx Batryticatus and its processed products and the limited content of AFT in Bombyx Batryticatus and the processed one were compared. The concentration of protein was measured with the Bradford methods and the difference of protein between Bombyx Batryticatus and its processed products was compared by SDS-PAGE analysis.

View Article and Find Full Text PDF

The purpose of this study is to compare microbial number, microbial biomass as well as soil enzyme activity between paddy field and dryland originated karst wetland ecosystems. The soil samples (0-20 cm) of uncultivated wetland, paddy field and dryland were collected in Huixian karst cave wetland, Guilin, China. Microbial numbers and biomass were detected using dilute plate incubation counting and chloroform fumigation-extraction, respectively.

View Article and Find Full Text PDF

The method for the determmation of trace boron, molybdenum, silver, tin and lead in geochemical samples by direct current are full spectrum direct reading atomic emission spectroscopy (DC-Arc-AES) was established. Direct current are full spectrum direct reading atomic emission spectrometer with a large area of solid-state detectors has functions of full spectrum direct reading and real-time background correction. The new electrodes and new buffer recipe were proposed in this paper, and have applied for national patent.

View Article and Find Full Text PDF