Determination of phenols in environmental water samples by ionic liquid-based headspace liquid-phase microextraction coupled with high-performance liquid chromatography.

J Sep Sci

School of Chemistry and Environmental Sciences, Henan Key Laboratory for Environmental Pollution Control, Henan Normal University, Xinxiang, Henan, P. R. China.

Published: January 2007


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Headspace liquid-phase microextraction (HS-LPME) has been applied to efficient enrichment of phenols such as 2-nitrophenol, 4-chlorophenol, 2,4-dichlorophenol, and 2-naphthol from water samples based on 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as an extractant. Some parameters that may influence HS-LPME were investigated. The linear range was in the range of 0.5-100 microg/L, and the enrichment factors and repeatability (RSD, n = 6) of the proposed method were in the range of 17.2-160.7 and 5.4-8.9%, respectively. The detection limit for each analyte ranged from 0.3 to 0.5 microg/L. Complex matrices of environmental water samples had a small effect on the enrichment, and this problem could be resolved by the addition of sodium ethylene diamine tetraacetate (EDTA) into the samples. The spiked recoveries were in the range of 89.4-114.2%. All these facts demonstrated that the proposed method, with merits of low cost, simplicity, and easy operation, would be a competitive alternative procedure for the determination of such compounds at trace level.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200600256DOI Listing

Publication Analysis

Top Keywords

water samples
12
environmental water
8
headspace liquid-phase
8
liquid-phase microextraction
8
proposed method
8
determination phenols
4
phenols environmental
4
samples
4
samples ionic
4
ionic liquid-based
4

Similar Publications

This study introduces a new, highly sensitive, and reliable method for detecting and measuring orthophosphate in environmental water samples. This method combines cetyltrimethylammonium bromide (CTAB)-mediated coacervation extraction with digital image-based colorimetry, providing a robust and efficient approach for orthophosphate analysis. In this system, CTAB, a cationic surfactant, serves a dual role as both an ion-pairing agent and an extraction medium.

View Article and Find Full Text PDF

The mechanical properties of the polymeric substrate or matrix where a cell grows affect cell behavior. Most studies have focused on relating elastic properties of polymeric substrates, which are time-independent, to cell behaviors. However, polymeric substrates and biological systems exhibit a time-dependent, often viscoelastic, mechanical response.

View Article and Find Full Text PDF

A novel magnetic nanostructured molecularly imprinted polymer probe (FeO@MIP) was developed for the continuous detection of Ti/Fe. The synthesis employed 50 nm FeO nanoparticles as the core matrix, with Ti and Fe serving as template molecules. Functional monomers α-methylacrylic acid (MAA) and acrylamide (AM) were used, along with ethylene glycol dimethacrylate (EGDMA) as the crosslinking agent and 2,2'-azobisisobutyronitrile (AIBN) as the polymerization initiator, utilizing a microwave-assisted procedure.

View Article and Find Full Text PDF

This study investigates the unique syneresis (self-shrinking) behavior of N-Terminally Fmoc-protected amino acid, Fmoc-hPhe-OH (Fmoc-homo-L-phenylalanine, abbreviated in this work as hF)-based hydrogel, and its potential in environmental remediation applications. Fmoc-hPhe-OH (hF) forms a hydrogel in 50 mM phosphate buffer (PB) of pH 7.4.

View Article and Find Full Text PDF

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF