98%
921
2 minutes
20
Headspace liquid-phase microextraction (HS-LPME) has been applied to efficient enrichment of phenols such as 2-nitrophenol, 4-chlorophenol, 2,4-dichlorophenol, and 2-naphthol from water samples based on 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as an extractant. Some parameters that may influence HS-LPME were investigated. The linear range was in the range of 0.5-100 microg/L, and the enrichment factors and repeatability (RSD, n = 6) of the proposed method were in the range of 17.2-160.7 and 5.4-8.9%, respectively. The detection limit for each analyte ranged from 0.3 to 0.5 microg/L. Complex matrices of environmental water samples had a small effect on the enrichment, and this problem could be resolved by the addition of sodium ethylene diamine tetraacetate (EDTA) into the samples. The spiked recoveries were in the range of 89.4-114.2%. All these facts demonstrated that the proposed method, with merits of low cost, simplicity, and easy operation, would be a competitive alternative procedure for the determination of such compounds at trace level.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jssc.200600256 | DOI Listing |
Anal Methods
September 2025
Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
This study introduces a new, highly sensitive, and reliable method for detecting and measuring orthophosphate in environmental water samples. This method combines cetyltrimethylammonium bromide (CTAB)-mediated coacervation extraction with digital image-based colorimetry, providing a robust and efficient approach for orthophosphate analysis. In this system, CTAB, a cationic surfactant, serves a dual role as both an ion-pairing agent and an extraction medium.
View Article and Find Full Text PDFNanoscale
September 2025
Department of Physics, University of Oxford, Parks Road, Oxford, OX1 3PU, UK.
The mechanical properties of the polymeric substrate or matrix where a cell grows affect cell behavior. Most studies have focused on relating elastic properties of polymeric substrates, which are time-independent, to cell behaviors. However, polymeric substrates and biological systems exhibit a time-dependent, often viscoelastic, mechanical response.
View Article and Find Full Text PDFAnal Methods
September 2025
Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection (Guangxi Normal University), Ministry of Education, Guilin 541004, China.
A novel magnetic nanostructured molecularly imprinted polymer probe (FeO@MIP) was developed for the continuous detection of Ti/Fe. The synthesis employed 50 nm FeO nanoparticles as the core matrix, with Ti and Fe serving as template molecules. Functional monomers α-methylacrylic acid (MAA) and acrylamide (AM) were used, along with ethylene glycol dimethacrylate (EGDMA) as the crosslinking agent and 2,2'-azobisisobutyronitrile (AIBN) as the polymerization initiator, utilizing a microwave-assisted procedure.
View Article and Find Full Text PDFChemistry
September 2025
Department of Chemistry, Birla Institute of Technology and Science-Pilani, K K Birla Goa Campus, Zuarinagar, Goa, 403726, India.
This study investigates the unique syneresis (self-shrinking) behavior of N-Terminally Fmoc-protected amino acid, Fmoc-hPhe-OH (Fmoc-homo-L-phenylalanine, abbreviated in this work as hF)-based hydrogel, and its potential in environmental remediation applications. Fmoc-hPhe-OH (hF) forms a hydrogel in 50 mM phosphate buffer (PB) of pH 7.4.
View Article and Find Full Text PDFBiomed Chromatogr
October 2025
Department of Pharmaceutical Analysis, Pharmacy School, Shenyang Pharmaceutical University, Shenyang, China.
A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.
View Article and Find Full Text PDF