Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses.

J Chromatogr B Analyt Technol Biomed Life Sci

Chemistry Applied Technology, Waters Corporation, 34 Maple Street, Milford, MA 01757, USA.

Published: June 2007


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A systematic, comprehensive strategy that optimizes sample preparation and chromatography to minimize matrix effects in bioanalytical LC/MS/MS assays was developed. Comparisons were made among several sample preparation methods, including protein precipitation (PPT), liquid-liquid extraction (LLE), pure cation exchange solid-phase extraction (SPE), reversed-phase SPE and mixed-mode SPE. The influence of mobile phase pH and gradient duration on the selectivity and sensitivity for both matrix components and basic analytes was investigated. Matrix effects and overall sensitivity and resolution between UPLC technology and HPLC were compared. The amount of specific matrix components, or class of matrix components, was measured in the sample preparation extracts by LC/MS/MS with electrospray ionization (ESI) using both precursor ion scanning mode and multiple reaction monitoring (MRM). PPT is the least effective sample preparation technique, often resulting in significant matrix effects due to the presence of many residual matrix components. Reversed-phase and pure cation exchange SPE methods resulted in cleaner extracts and reduced matrix effects compared to PPT. The cleanest extracts, however, were produced with polymeric mixed-mode SPE (both reversed-phase and ion exchange retention mechanisms). These mixed-mode sorbents dramatically reduced the levels of residual matrix components from biological samples, leading to significant reduction in matrix effects. LLE also provided clean final extracts. However, analyte recovery, particularly for polar analytes, was very low. Mobile phase pH was manipulated to alter the retention of basic compounds relative to phospholipids, whose retention tends to be relatively independent of pH. In addition to the expected resolution, speed and sensitivity benefits of UPLC technology, a paired t-test demonstrated a statistically significant improvement with respect to matrix effects when this technology was chosen over traditional HPLC. The combination of polymeric mixed-mode SPE, the appropriate mobile phase pH and UPLC technology provides significant advantages for reducing matrix effects resulting from plasma matrix components and in improving the ruggedness and sensitivity of bioanalytical methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2006.12.030DOI Listing

Publication Analysis

Top Keywords

matrix effects
32
matrix components
24
sample preparation
16
matrix
14
mixed-mode spe
12
mobile phase
12
uplc technology
12
systematic comprehensive
8
comprehensive strategy
8
reducing matrix
8

Similar Publications

Background: Superficial injection of hyaluronic acid (HA)-based gels is a widely used method to restore skin quality and achieve a more youthful appearance. While the clinical benefits of such procedures are well established, their biological mechanisms of action remain poorly understood.

Objective: This study aimed to evaluate the effectiveness of two cross-linked HA gels (IPN-12.

View Article and Find Full Text PDF

Kinesin family member 14 (KIF14) has been implicated in the progression of multiple cancer types, yet its role in colorectal cancer (CRC) metastasis remains undefined. Here, we assesse KIF14 expression in CRC specimens and explore its clinical and functional significance. KIF14 upregulation is frequently observed in CRC tissues and is correlated with advanced tumor stage and reduced overall survival.

View Article and Find Full Text PDF

A novel magnetic nanostructured molecularly imprinted polymer probe (FeO@MIP) was developed for the continuous detection of Ti/Fe. The synthesis employed 50 nm FeO nanoparticles as the core matrix, with Ti and Fe serving as template molecules. Functional monomers α-methylacrylic acid (MAA) and acrylamide (AM) were used, along with ethylene glycol dimethacrylate (EGDMA) as the crosslinking agent and 2,2'-azobisisobutyronitrile (AIBN) as the polymerization initiator, utilizing a microwave-assisted procedure.

View Article and Find Full Text PDF

Background And Aims: Cholangiopathies, including primary sclerosing cholangitis (PSC), primary biliary cholangitis (PBC), and post-COVID-19 cholangiopathy (PCC), involve chronic cholangiocyte injury, senescence, epithelial-stromal crosstalk, and progressive fibrosis. However, effective in vitro models to capture these interactions are limited. Here, we present a scaffold-free 3D multilineage spheroid model, composed of hepatocyte-like cells (HepG2), cholangiocytes (H69), and hepatic stellate cells (LX-2), designed to recapitulate early fibrogenic responses driven by senescent cholangiocytes.

View Article and Find Full Text PDF

Purpose: Tracer kinetic models are used in arterial spin labeling (ASL); however, deciding which model parameters to fix or fit is not always trivial. The identifiability of the resultant system of equations is useful to consider, since it will likely impact parameter uncertainty. Here, we analyze the identifiability of two-compartment models used in multi-echo (ME) blood-brain-barrier (BBB)-ASL and evaluate the reliability of the fitted water-transfer rate ).

View Article and Find Full Text PDF