Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Sample selection is often used to improve the cost-effectiveness of near-infrared (NIR) spectral analysis. When raw NIR spectra are used, however, it is not easy to select appropriate samples, because of background interference and noise. In this paper, a novel adaptive strategy based on selection of representative NIR spectra in the continuous wavelet transform (CWT) domain is described. After pretreatment with the CWT, an extension of the Kennard-Stone (EKS) algorithm was used to adaptively select the most representative NIR spectra, which were then submitted to expensive chemical measurement and multivariate calibration. With the samples selected, a PLS model was finally built for prediction. It is of great interest to find that selection of representative samples in the CWT domain, rather than raw spectra, not only effectively eliminates background interference and noise but also further reduces the number of samples required for a good calibration, resulting in a high-quality regression model that is similar to the model obtained by use of all the samples. The results indicate that the proposed method can effectively enhance the cost-effectiveness of NIR spectral analysis. The strategy proposed here can also be applied to different analytical data for multivariate calibration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-006-0967-3DOI Listing

Publication Analysis

Top Keywords

spectral analysis
12
nir spectra
12
adaptive strategy
8
calibration samples
8
continuous wavelet
8
nir spectral
8
background interference
8
interference noise
8
selection representative
8
representative nir
8

Similar Publications

Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.

View Article and Find Full Text PDF

Acute lymphoblastic leukemia (ALL) is the most common hematologic malignancy in children. Current clinical diagnosis primarily relies on invasive detection methods, while molecular subtyping remains a complex and time-consuming process. This study innovatively employed silver nanoparticle-based surface-enhanced Raman spectroscopy (SERS) technology to systematically analyze 116 serum samples, including those with breakpoint cluster region-Abelson (-) fusion genotype, mixed-lineage leukemia (, also known as lysine methyltransferase 2A, ) gene rearrangement subtype, T-lymphoblastic ALL, and healthy controls.

View Article and Find Full Text PDF

Accurate differentiation between persistent vegetative state (PVS) and minimally conscious state and estimation of recovery likelihood in patients in PVS are crucial. This study analyzed electroencephalography (EEG) metrics to investigate their relationship with consciousness improvements in patients in PVS and developed a machine learning prediction model. We retrospectively evaluated 19 patients in PVS, categorizing them into two groups: those with improved consciousness ( = 7) and those without improvement ( = 12).

View Article and Find Full Text PDF

Significance: The spatial and temporal distribution of fluorophore fractions in biological and environmental systems contains valuable information about the interactions and dynamics of these systems. To access this information, fluorophore fractions are commonly determined by means of their fluorescence emission spectrum (ES) or lifetime (LT). Combining both dimensions in temporal-spectral multiplexed data enables more accurate fraction determination while requiring advanced and fast analysis methods to handle the increased data complexity and size.

View Article and Find Full Text PDF

Extinction in thin polymer films containing nanoparticles is important to photovoltaics, sensors, and interconnects. Extinction measured in 1-millimeter-thin films containing plasmonic nanoparticles increased with nanoparticle density to levels higher than predicted. Yet, enhancement of extinction was not measured in <100-nanometer-thin films containing high-density plasmonic nanoparticles.

View Article and Find Full Text PDF