Background: Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear.
Methods And Results: Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner. Programming minimized ventricular pacing. The primary end point was the proportion of SVT episodes inappropriately detected from the time of programming until crossover or end of study. On a per-episode basis, 42% of the episodes in the single-chamber arm and 69% of the episodes in the dual-chamber arm were due to SVT. Mortality (3.5% in both groups) and early study withdrawal (14% single-chamber, 11% dual-chamber) were similar in both groups. The rate of inappropriate detection of SVT was 39.5% in the single-chamber detection arm compared with 30.9% in the dual-chamber arm. The odds of inappropriate detection were decreased by almost half with the use of the dual-chamber detection enhancements (odds ratio, 0.53; 95% confidence interval, 0.30 to 0.94; P=0.03).
Conclusions: Dual-chamber ICDs, programmed to optimize detection enhancements and to minimize ventricular pacing, significantly decrease inappropriate detection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.105.594531 | DOI Listing |
Anal Methods
September 2025
Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
This study introduces a new, highly sensitive, and reliable method for detecting and measuring orthophosphate in environmental water samples. This method combines cetyltrimethylammonium bromide (CTAB)-mediated coacervation extraction with digital image-based colorimetry, providing a robust and efficient approach for orthophosphate analysis. In this system, CTAB, a cationic surfactant, serves a dual role as both an ion-pairing agent and an extraction medium.
View Article and Find Full Text PDFAnal Chem
September 2025
Institute of Biological Chemistry, Faculty of Chemistry, University of Vienna, Währinger Str. 38, 1090 Vienna, Austria.
The discovery of solute precursors of crystalline materials, such as biominerals, recently challenged the classical nucleation theory (CNT). One emerging method for investigating these early-stage intermediates in solution is dissolution dynamic nuclear polarization (dDNP)-enhanced nuclear magnetic resonance (NMR) spectroscopy. Recent applications of dDNP to calcium carbonate (CaC) and calcium phosphate (CaP) mineralization have demonstrated the feasibility of identifying and tracing very early-stage prenucleation clusters (PNCs).
View Article and Find Full Text PDFAnal Methods
September 2025
Key Laboratory of Ecology of Rare and Endangered Species and Environmental Protection (Guangxi Normal University), Ministry of Education, Guilin 541004, China.
A novel magnetic nanostructured molecularly imprinted polymer probe (FeO@MIP) was developed for the continuous detection of Ti/Fe. The synthesis employed 50 nm FeO nanoparticles as the core matrix, with Ti and Fe serving as template molecules. Functional monomers α-methylacrylic acid (MAA) and acrylamide (AM) were used, along with ethylene glycol dimethacrylate (EGDMA) as the crosslinking agent and 2,2'-azobisisobutyronitrile (AIBN) as the polymerization initiator, utilizing a microwave-assisted procedure.
View Article and Find Full Text PDFAnn Palliat Med
September 2025
Department of Pathology and Laboratory Medicine, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
Radical esophagectomy remains the cornerstone of curative treatment for esophageal cancer, but is frequently complicated by postoperative events, most notably anastomotic leakage. Anastomotic leakage, occurring in up to 30% of cases, is multifactorial in origin and significantly increases morbidity and mortality. This review aims to summarize current management strategies, highlight emerging therapies, and identify persistent clinical challenges related to this complication.
View Article and Find Full Text PDFJ Am Chem Soc
September 2025
Institute for Molecules and Materials, Radboud University, Heyendaalseweg 135, 6525 AJ Nijmegen, The Netherlands.
Non-hydrogenative para-hydrogen-induced polarization (nhPHIP) has proven a powerful tool for the enhanced NMR detection of several classes of metabolites in complex mixtures. Particularly, compounds carrying an α-amino acid motif have been previously detected and quantified in biological samples and natural extracts at submicromolar concentrations using 2D nhPHIP NMR spectroscopy. This technique is here applied for the first time in a semi-targeted metabolomics NMR study on urine from patients suffering from Pyridoxine-Dependent Epilepsy (PDE), currently diagnosed by the presence of dilute unique biomarkers.
View Article and Find Full Text PDF