The changes caused by modification of biomechanical properties of a bone.

Stud Health Technol Inform

Institute of Computer Science, Silesian University, Department of Biomedical Computer Systems Poland, 41-200 Sosnowiec, ul. Bedzińska 39.

Published: April 2005


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The paper presents the distribution of the parameters of mechanical stiffness in a sample of animal bone. The parameters are measured at different distances from the cortical bone. As it is widely known, bone properties vary significantly depending on the length of the bone. Additionally, the properties of trabecular bone also depend on its distance from the cortical bone. The study presents the results for both samples of normal bone tissue and samples of bone tissue with chemically modified biomechanical properties. For each sample a matrix of measurement points was defined. For each measurement point, a micro hardness test was performed in order to define hardness of the micro volume and to measure the Young's modulus. This test was carried out using Micro-Combi-Tester equipment. Micro hardness was measured with Vickers diamond, and the analysis of deformation properties was realized by the Olivier and Pharr method. The application of Oliver and Pharr method enabled the calculation of Young's modulus directly from the unloading curve. Additionally, mineral density for all samples was measured using Dual Energy X-ray Absorptiometry method. This study allowed for comparison of bone mineral density parameter with Young's modulus. The aim of this comparison was to demonstrate changes caused by modification of biomechanical properties of bone.

Download full-text PDF

Source

Publication Analysis

Top Keywords

biomechanical properties
12
young's modulus
12
bone
11
changes caused
8
caused modification
8
modification biomechanical
8
properties bone
8
cortical bone
8
bone tissue
8
micro hardness
8

Similar Publications

Objective: Due to its inherent high instability, the selection of fixation strategies for unilateral Denis type II sacral fractures remains a controversial challenge in the field of traumatic orthopedics. This study focuses on unilateral Denis type II sacral fractures. By applying three different fixation methods, it aims to explore their biomechanical properties and provide a theoretical basis for optimizing clinical fixation protocols.

View Article and Find Full Text PDF

Brillouin microscopy allows mechanical investigations of biological materials at the subcellular level and can be integrated with Raman spectroscopy for simultaneous chemical mapping, thus enabling a more comprehensive interpretation of biomechanics. The present study investigates different in vitro glioblastoma models using a combination of Brillouin and Raman microspectroscopy. Spheroids of the U87-MG cell line and two patient-derived cell lines as well as patient-derived organoids were used.

View Article and Find Full Text PDF

Microstructure of the anterior iliac Spine: Identification of trends and relation to fracture tolerance.

J Mech Behav Biomed Mater

September 2025

Center for Applied Biomechanics, University of Virginia, 4040 Lewis and Clark Drive, Charlottesville, VA, 22911, United States.

Seatbelt-induced pelvic iliac wing injuries have been observed since the 1970s, but only recently has there been quantification of fracture tolerance and injury risk of the iliac wing. Previous studies have shown a wide variation in iliac wing fracture tolerance with no significant relationships to pelvis size, sex, or other factors. A weighted average bone density (BD) calculation of the entire iliac wing produced the best predictive performance of fracture tolerance in parametric (Weibull) survival models.

View Article and Find Full Text PDF

A numerical investigation of the kinematic and fluid dynamic behaviour of an intramuscular autoinjector designed for optimising injection efficiency.

Med Eng Phys

October 2025

Department of Mechanical Engineering, University of Cape Town, 7701, South Africa; Centre for Research in Computational and Applied Mechanics (CERECAM), University of Cape Town, 7701, South Africa.

The usability and versatility of autoinjectors in managing chronic and autoimmune diseases have made them increasingly attractive in medicine. However, investigations into autoinjector designs require an understanding of the kinematic properties and fluid behaviour during injection. To optimise injection efficiency, this study develops a mathematical and computational fluid dynamics (CFD) model of an IM autoinjector by investigating the effects of viscosity, needle length, needle diameter, and medication volume on the injection process.

View Article and Find Full Text PDF

Insects and plants have been locked in an evolutionary arms race spanning 350 million years. Insects evolved specialized tools to cut into plant tissue, and plants, to counter these attacks, developed diverse defence strategies. Much previous worked has focused on chemical defences.

View Article and Find Full Text PDF