Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To predict the postoperative IOL position and refraction as accurately as possible independent of individualization of the parameters.

Setting: Universitats-Augenklinik, Mainz, Germany, and Vienna, Austria.

Methods: One patient cohort (189 eyes, Vienna) was used to calibrate the prediction method, which was then applied to a second cohort (65 eyes, Mainz). All calculations were based on consistent numerical ray tracing of the pseudophakic eye using the original manufacturer's intraocular lens (IOL) data (radii, thickness, refractive index). A new algorithm to predict IOL position was developed. Ultrasound (US) axial lengths were calibrated relative to partial coherence interferometry (PCI). Corneal radii extracted from topography were checked against radii measured with the IOLMaster (Zeiss) and by Littmann keratometry.

Results: Zero mean prediction errors for IOL position and refraction were obtained without adjusting the parameters and with PCI lengths or US lengths calibrated relative to the PCI values. There was no significant loss of accuracy of US data compared to PCI data. Corneal radii extracted from topography were slightly but statistically significantly different from the Littmann values, and they were more accurate than the latter with respect to prediction error. The measured mean central IOL position (distance from posterior corneal surface) for all IOL types was 4.580 mm, a value very close to the mean recalculated from A-constants (4.587 mm). The difference in the individual central IOL position relative to the mean value depended only linearly (ie, no higher orders such as square or cubic are needed) on axial length, with the mean central IOL position as a free parameter. This parameter should be 4.6 +/- 0.2 mm (the same value as independently measured or recalculated) to obtain zero steepness of the prediction error as a function of axial length, producing zero bias for long and short eyes.

Conclusions: Calculation errors from formulas and confusing adjusting parameters can be avoided if calculations and measurements are performed on a clear and simple physical basis. Nevertheless, an individual prediction error, typically 0.5 to 1.0 diopter, seems to be unavoidable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2004.07.004DOI Listing

Publication Analysis

Top Keywords

iol position
24
position refraction
12
prediction error
12
central iol
12
intraocular lens
8
iol
8
lengths calibrated
8
calibrated relative
8
corneal radii
8
radii extracted
8

Similar Publications

Intraocular repair for subluxation of a multifocal intraocular lens (MFIOL) can be challenging, especially in toric models. Herein, we report a case of a 43-year-old man with a subluxated toric-type single-piece trifocal intraocular lens (IOL) with a C-loop that was spared using suture repositioning. Pars plana suturing was performed using the haptic externalization technique, and the tram-track suture technique was employed to flatten the tilted toric MFIOL.

View Article and Find Full Text PDF

Digital marking versus manual marking technique for toric intraocular lens alignment: a meta-analysis.

BMC Ophthalmol

September 2025

Department of Ophthalmology, Tongji Medical College, The Central Hospital of Wuhan, Huazhong University of Science and Technology, No 26 Shengli Street, Wuhan, 430014, China.

Background: Manual and digital-assisted marking are the two main marking methods used for toric intraocular lens (IOL) in cataract surgery. However, there is a lack of consensus regarding the consistency in accuracy for these two methods. This meta-analysis aimed to compare and evaluate the accuracy of digital and manual marking techniques for toric IOL alignment during cataract surgery.

View Article and Find Full Text PDF

Although most patients are satisfied with their vision after multifocal intraocular lens (IOL) implantation, dissatisfaction has been reported for various reasons, including poor visual outcomes and visual disturbances. Many published reports hypothesise that preoperative angle kappa may be an associated factor in patient dissatisfaction. Therefore, there is considerable interest in understanding the connection between preoperative angle kappa and visual outcome after multifocal IOL implantation.

View Article and Find Full Text PDF

Long-Term Effectiveness of a Monofocal Intraocular Lens (IOL) Enhanced for Intermediate Vision: A 5-Year Follow-Up Study.

J Clin Med

August 2025

Eye Clinic, Department of Neuroscience, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, Largo Brambilla 3, 50134 Florence, Italy.

: The Tecnis Eyhance is an enhanced monofocal intraocular lens (IOL) designed to improve intermediate vision without compromising distance clarity or increasing the incidence of photic phenomena. Although short-term results have been encouraging, long-term data remain limited. This study presents the 5-year follow-up of a previously published 6-month clinical evaluation, aiming to assess the stability of visual, optical, and patient-reported outcomes over time.

View Article and Find Full Text PDF

Purpose: To assess the real-world distance and intermediate visual outcomes, rotational stability, and adverse events (AEs) of patients implanted with a Clareon aspheric monofocal toric intraocular lens (IOL) preloaded in the AutonoMe delivery system (Alcon, USA; models CNA0T2 to CNA0T6) up to one-month postoperative.

Methods: Surgical charts from January 2021 to October 2023 were reviewed for adult patients (≥18 years) who previously received a CNA0T2 to CNA0T6 (T2 to T6) IOL during uneventful cataract surgery and were targeted for emmetropia/first minus. Overall, charts from 193 eyes of 121 patients were screened, with 161 eyes of 107 patients included in the study.

View Article and Find Full Text PDF