Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Attenuation artifact remains a substantial limitation to confident interpretation of images and reduces laboratory efficiency by requiring comparison of stress and rest image sets. Attenuation-corrected stress-only imaging has the potential to ameliorate these limitations.

Methods And Results: Ten experienced nuclear cardiologists independently interpreted 90 stress-only electrocardiography (ECG)-gated technetium 99m sestamibi images in a sequential fashion: myocardial perfusion imaging (MPI) alone, MPI plus ECG-gated data, and attenuation-corrected MPI with ECG-gated data. Images were interpreted for diagnostic certainty (normal, probably normal, equivocal, probably abnormal, abnormal, and perceived need for rest imaging). With stress MPI data alone, only 37% of studies were interpreted as definitely normal or abnormal, with a very high perceived need for rest imaging (77%). The addition of gated data did not alter the interpretations. However, attenuation-corrected data significantly increased the number of studies characterized as definitely normal or abnormal (84%, P <.005) and significantly reduced the perceived need for rest imaging (43%, P <.005). These results were confirmed by use of a nonsequential consensus interpretation of three readers.

Conclusion: Attenuation correction applied to studies with stress-only Tc-99m ECG-gated single photon emission computed tomography images significantly increases the ability to interpret studies as definitely normal or abnormal and reduces the need for rest imaging. These findings may improve laboratory efficiency and diagnostic accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nuclcard.2004.03.005DOI Listing

Publication Analysis

Top Keywords

mpi ecg-gated
8
ecg-gated data
8
perceived rest
8
rest imaging
8
definitely normal
8
normal abnormal
8
imaging
5
data
5
clinical attenuation
4
attenuation correction
4

Similar Publications

There are no large-scale reports on the prediction of major cardiac events (MCEs) and risk stratification using phase entropy, a measure of left ventricular (LV) dyssynchrony, in Japanese patients with known or suspected coronary artery disease (CAD). We retrospectively investigated 5541 patients with known or suspected CAD who underwent rest Tl and stress Tc-tetrofosmin electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) and followed them for three years to confirm their prognosis. We excluded patients undergoing revascularization within 3 months before and after the SPECT and those with non-sinus rhythm.

View Article and Find Full Text PDF

Comparative evaluation of a novel [F] F-Labeled PET tracer XTR004 against [N] ammonia in myocardial perfusion imaging for coronary artery disease.

Eur J Nucl Med Mol Imaging

April 2025

Department of Nuclear Medicine, Peking Union Medical College Hospital. Chinese Academy of Medical Science & Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Aims: This study aimed to evaluate image quality, myocardial perfusion, and diagnostic performance of a novel [F]F-labeled PET tracer, XTR004 PET, myocardial perfusion imaging (MPI) compared with [N]Ammonia (NH) PET MPI.

Methods And Results: Forty-seven patients with suspected or known coronary artery disease (CAD) were prospectively enrolled to undergo one-day rest/ATP-stress XTR004 and NH electrocardiograph-gated PET imaging within 2 weeks. Among them, twenty-six patients underwent invasive coronary angiography (ICA), and nineteen were identified with flow-limited CAD (stenosis ≥ 70%).

View Article and Find Full Text PDF
Article Synopsis
  • The study explores the use of a deep-learning network to correct motion blur in myocardial perfusion imaging (MPI) with SPECT, aiming to improve the detection of perfusion defects.
  • Researchers trained the network on 197 ECG-gated SPECT-MPI images and tested its effectiveness on a separate dataset of 194 subjects with simulated lesions, analyzing results through receiver-operating characteristic (ROC) curves.
  • Results indicated that deep-learning motion correction significantly enhances detectability of perfusion defects, achieving higher accuracy in specific cardiac phases versus traditional ungated studies, especially in reduced-count scenarios.
View Article and Find Full Text PDF

Background: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization.

Methods: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease.

View Article and Find Full Text PDF

Purpose: Cardiac resynchronization therapy (CRT) has been established as an important therapy for heart failure. Mechanical dyssynchrony has the potential to predict responders to CRT. The aim of this study was to report the development and the validation of machine learning models which integrate ECG, gated SPECT MPI (GMPS), and clinical variables to predict patients' response to CRT.