Purpose: It is assumed that wavefront error data arising from aberrometry are adequately described by a Zernike polynomial function, although this assumption has not been extensively tested. Inaccuracies in wavefront error may compromise clinical testing and refractive correction procedures. The current retrospective study correlates visual acuity with corneal wavefront error and with the residual surface elevation error after fitting with the Zernike method.
Methods: Corneal topography maps were obtained from 32 keratoconus cases, 27 postoperative penetrating keratoplasty cases, and 29 postoperative conductive keratoplasty cases (88 total). The best spectacle-corrected visual acuity (BSCVA) for each case ranged from -0.2 to 1.3 logarithm of the minimum angle of resolution (logMAR) units (20/12.5-20/400). Topography was analyzed to determine wavefront error and the elevation fit error for a 4-mm optical zone. The 4th and 10th expansion series were analyzed with the 0th-order (piston) and 1st order (tip and tilt) removed. Linear regression analysis was performed. The difference in root mean square (RMS) error between the 4th- and 10th-order analyses was assessed for both wavefront and elevation fit error.
Results: The correlation of BSCVA to wavefront error for 4th-order terms was moderately strong and significant (R2=0.581; P<0.001). The 10th-order correlation for wavefront error had a similar result (R2=0.565; P<0.001), but the regression was not significantly different from the 4th-order result. The correlation of BSCVA to the elevation fit error was strong and significant for the 4th order (R2=0.658; P<0.001). The 10th-order data had a similar result (R2=0.509; P<0.001), and there was no significant difference between the two regressions. Only 72% of the cases showed a shift toward increased wavefront error with the 10th-order series, whereas 18% lost wavefront error. All cases showed a shift toward improved elevation fit with the 10th-order expansion.
Conclusions: The wavefront error correlation to acuity was moderately strong, but the corneal elevation fit error also strongly correlated with visual acuity, indicating that Zernike polynomials do not fully characterize the surface shape features that influence vision and that exist in postsurgical or pathologic eyes. In addition, the change in wavefront error when using a larger expansion series was found to increase or diminish somewhat unpredictably. The authors conclude that Zernike polynomials fail to model all the information that influences visual acuity, which may confound clinical diagnosis and treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1167/iovs.03-0190 | DOI Listing |
IEEE Trans Med Imaging
September 2025
In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media.
View Article and Find Full Text PDFJ Refract Surg
September 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.
Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).
Cureus
August 2025
Department of Ophthalmology, Kanazawa Medical University, Uchinada, JPN.
Intraocular repair for subluxation of a multifocal intraocular lens (MFIOL) can be challenging, especially in toric models. Herein, we report a case of a 43-year-old man with a subluxated toric-type single-piece trifocal intraocular lens (IOL) with a C-loop that was spared using suture repositioning. Pars plana suturing was performed using the haptic externalization technique, and the tram-track suture technique was employed to flatten the tilted toric MFIOL.
View Article and Find Full Text PDFMicromachines (Basel)
August 2025
The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China.
Silicon carbide (SiC), a wide-bandgap semiconductor, is renowned for its exceptional performance in power electronics and extreme-temperature environments. However, precision low-loss laser slicing of SiC is impeded by energy divergence and crack delamination induced by refractive-index-mismatch interfacial aberrations. This study presents an integrated laser slicing system based on a liquid crystal on silicon spatial light modulator (LCOS-SLM) to address aberration-induced focal elongation and energy inhomogeneity.
View Article and Find Full Text PDFSensors (Basel)
August 2025
School of Information and Communication Engineering, Communication University of China, Beijing 100024, China.
Integrated Sensing And Communication (ISAC) has been applied to the Internet of Things (IoT) network as a promising 6G technology due to its ability to enhance spectrum utilization and reduce resource consumption, making it ideal for high-precision sensing applications. However, while the introduction of millimeter Wave (mmWave) and massive Multiple-Input Multiple-Output (MIMO) technologies can enhance the performance of ISAC systems, they extend the near-field region, rendering traditional channel parameter estimation algorithms ineffective due to the spherical wavefront channel model. Aiming to address the challenge, we propose a tensor-based channel parameter estimation and localization algorithm for the near-field mmWave massive MIMO-Orthogonal Frequency Division Multiplexing (OFDM) ISAC systems.
View Article and Find Full Text PDF