Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Health Canada reported recently that medical devices containing di(2-ethylhexyl) phthalate (DEHP) should not be used in the clinical treatment of infants, young boys, pregnant women, and nursing mothers. The risk assessment of DEHP released from PVC medical devices is an important issue for hospitalized patients. In this study, a simple, accurate, low-contamination and high-throughput analytical technique for the determination of DEHP in intravenous (IV) solution was developed using column-switching liquid chromatography/mass spectrometry (LC/MS) with an extraction mini-column. The sample preparation for on-line extraction involved simply mixing IV solution with internal standard as DEHP-d(4) in LC glass vials. The IV fat emulsion drug sample cannot be analyzed directly, hence this sample spiked with DEHP-d(4) solution was extracted by hexane and measured by column-switching LC/MS yielding an average recovery of 92.2% (C.V.=7.8%, n=5). A linear response was found for a variety of drugs tested within the validated range of 0.1 or 0.5-10 microg/ml with correlation coefficients (r) greater than 0.99. These results suggest that this method can assay background exposure to DEHP released from PVC medical devices in the patients. The method was applied to various IV solution samples to establish the first screening method for DEHP released from medical devices with respect to their safety.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0731-7085(03)00019-0DOI Listing

Publication Analysis

Top Keywords

medical devices
20
released pvc
12
pvc medical
12
dehp released
12
column-switching lc/ms
8
di2-ethylhexyl phthalate
8
intravenous solution
8
medical
5
devices
5
solution
5

Similar Publications

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.

View Article and Find Full Text PDF

The stress urinary incontinence (SUI) is a difficulty in urology and current sub-urethral sling treatments are associated with inflamation and recurrence. In this study, we developed a novel tissue-engineered sling with myogenic induced adiposederived stem cells (MI-ADSCs) sheets induced by 5-Aza and combined with electrospun scaffolds of silk fibroin and poly(lactide-co-glycolide) (SF/PLGA) for the treatment of stress urinary incontinence. MI-ADSCs increased α-SMA, MyoD and Desmin the mRNA and protein expression.

View Article and Find Full Text PDF

Introduction: This study aimed to evaluate surgeons' ergonomic satisfaction when using laparoscopic energy devices and to investigate how prolonged use affects muscle fatigue and surgical performance.

Methods: A two-part study, including a survey and a kinesiologic experiment, was conducted to compare 4 laparoscopic energy devices (D1-D4). Thirty surgeons completed a structured survey assessing ergonomic factors such as device weight, grip strength, handle design, comfort, and trigger location.

View Article and Find Full Text PDF