Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We present a point-diffraction interferometer that has been specially devised to perform absolute distance measurements in three dimensions. It is composed of two main parts: One is a target that moves in three dimensions, and the other is a stationary two-dimensional array of photodetectors. The target is made of point-diffraction sources that emit two spherical wave fronts, whose interference is monitored by the photodetectors. Application of a phase-shifting technique allows the phase values of the photodetectors to be precisely measured, which are then fitted to a geometric model of multilateration so as to determine the xyz location of the target by minimization of least-squares errors. Experimental results show that the proposed diffraction interferometer is capable of measuring the xyz coordinates of the target with a volumetric uncertainty of less than 1.0 microm over a working volume of a 100-mm side.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.41.005921DOI Listing

Publication Analysis

Top Keywords

absolute distance
8
three dimensions
8
distance measurement
4
measurement two-point-diffraction
4
two-point-diffraction interferometry
4
interferometry point-diffraction
4
point-diffraction interferometer
4
interferometer specially
4
specially devised
4
devised perform
4

Similar Publications

AI-enhanced predictive modeling for treatment duration and personalized treatment planning of cleft lip and palate therapy.

Int J Comput Assist Radiol Surg

September 2025

Division of Plastic and Reconstructive Surgery, Neonatal and Pediatric Craniofacial Airway Orthodontics, Department of Surgery, Stanford University School of Medicine, 770 Welch Road, Palo Alto, CA, 94394, USA.

Background: Alveolar molding plate treatment (AMPT) plays a critical role in preparing neonates with cleft lip and palate (CLP) for the first reconstruction surgery (cleft lip repair). However, determining the number of adjustments to AMPT in near-normalizing cleft deformity prior to surgery is a challenging task, often affecting the treatment duration. This study explores the use of machine learning in predicting treatment duration based on three-dimensional (3D) assessments of the pre-treatment maxillary cleft deformity as part of individualized treatment planning.

View Article and Find Full Text PDF

Mitral annular disjunction distance is associated with adverse outcomes in children and young adults with connective tissue disorders.

J Cardiovasc Magn Reson

September 2025

Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts; Department of Pediatrics, Harvard Medical School, Boston, Massachusetts.

Introduction: Mitral annular disjunction (MAD) is a pathologic fibrous separation of the mitral valve hinge point from the ventricular myocardium. The aims of this study were to describe the range of MAD distance by cardiac magnetic resonance (CMR) in children and young adults with connective tissue disorders (CTDs) versus a healthy control sample, and to assess the MAD distance as a predictor of adverse cardiovascular outcomes.

Methods: This was a retrospective, single-center study of healthy subjects and patients with Marfan syndrome, Loeys-Dietz syndrome, Ehlers-Danlos syndrome, or nonspecific CTD who underwent CMR between 01/01/2000 and 01/01/2020.

View Article and Find Full Text PDF

Purpose: To validate a custom FIJI (ImageJ) program for more reproducible, faster curvilinear periorbital measurements, as compared with 2 custom artificial intelligence-based tools.

Design: Combined technical validation and method comparison study.

Subjects: Front-facing photographs of 45 cleft palate syndromic patients.

View Article and Find Full Text PDF

Purpose: To determine the proximity between the thinnest corneal point (TCP) and focal corneal weakening in normal, subclinical keratoconus (SKC), and manifest keratoconus (KC) eyes using motion-tracking Brillouin microscopy.

Design: Prospective cross-sectional study.

Participants: Ninety-five eyes from 95 patients were evaluated: 40 from bilaterally normal patients (controls), 40 from patients with SKC, and 15 from patients with manifest KC.

View Article and Find Full Text PDF

Predictive modeling of bruising in broiler chickens using machine learning algorithms.

Poult Sci

August 2025

Department of Agricultural Education, Faculty of Industrial Education and Technology, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand. Electronic address:

Bruising chicken broiler is caused by physical stress and injury to the skin and underlying tissues is a major problem in poultry production, affecting both animal welfare and economic outcomes. The aim of this study was to classify the bruising class (low or high percentage of carcass showing bruise at slaughterhouse) per truckload comparing the predictive performance of six machine learning (ML) models- Least Absolute Shrinkage and Selection Operator (LASSO), Classification Tree (CT), Random Forest (RF), Naïve Bayes (NB), Support Vector Machine (SVM), and Extreme Gradient Boosting (XGB)- and using a data set including information about season, time of transport, sex of the flock, flock size, chicken age, chicken mean body weight, housing stocking density, on farm mortality and culling rate, and feed withdrawal time. The general objective was to offer tools for the early detection of flocks with a higher likelihood of bruising and to highlight how ML can support decision-making, strengthen welfare monitoring programs, and reduce economic losses in commercial broiler production.

View Article and Find Full Text PDF