The objective of this prospective, analytic study was to identify predictors and describe the demographic and clinical correlates of head computed tomography (CT) evaluation in patients with poisoning or drug overdose and altered mental status. Forty-three patients that were evaluated by head CT and 109 that were not evaluated by head CT were entered into the study at a poison control center. None of the 43 scanned patients had any acute findings on head CT. A logistic regression model yielded 4 predictors that were statistically associated with the ordering of a head CT scan: Glasgow Coma Scale (GCS) < or = 8 (odds ratio [OR]: 2.3; 95% confidence interval [CI] 1.03-5.7); age > or = 41 years (OR 5.3; 95% CI 2.2-13); use of drugs or abuse by history (OR 2.8; 95% CI 1.04-7.6); and witnessed seizure activity (OR 4.8; 95% CI 1.3-17.9). We also tested 2 additional models to identify predictors of hospital admission, 1 with and 1 without CT scan included as a covariate. In the first model, only GCS =8 was a significant predictor of admission (OR 10.7; 95% CI 2.4-47.2). When the use of head CT was added to the second model, it also emerged as an independent explanatory predictor of admission (OR 4.8; CI 95% 1.2-20.4) in addition to GCS (OR 10.1; 95% CI 2.2-45.4). In this pilot study, patients presenting to the emergency department (ED) with suspected poisoning or drug overdose were found to have a low likelihood of abnormal findings on head CT scan. Those among whom CT scans were obtained were more likely to be admitted to the hospital from the ED, despite negative findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1053/ajem.2002.32632 | DOI Listing |
J Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFBMC Oral Health
September 2025
Oral and Maxillofacial Radiology Department, Cairo university, Cairo, Egypt.
Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.
Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.
Radiol Phys Technol
September 2025
Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Department of Orthopaedics and Trauma Surgery, Orthopaedic Oncology, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.
Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to assess femoral and tibial torsion. While CT offers high spatial resolution, it involves ionizing radiation. MRI avoids radiation but requires multiple sequences and extended acquisition time.