Publications by authors named "Siming Zuo"

Motion artifacts can be a significant noise source in biomagnetic measurements when magnetic sensors are not separated from the signal source. In ambient environments, motion artifacts can be up to ten times stronger than the desired signals, varying with environmental conditions. This study evaluates the variability of these artifacts and the effectiveness of a gradiometer in reducing them in such settings.

View Article and Find Full Text PDF

Neuromuscular diseases are a prevalent cause of prolonged and severe suffering for patients, and with the global population aging, it is increasingly becoming a pressing concern. To assess muscle activity in NMDs, clinicians and researchers typically use electromyography (EMG), which can be either non-invasive using surface EMG, or invasive through needle EMG. Surface EMG signals have a low spatial resolution, and while the needle EMG provides a higher resolution, it can be painful for the patients, with an additional risk of infection.

View Article and Find Full Text PDF

Muscles are the actuators of all human actions, from daily work and life to communication and expression of emotions. Myography records the signals from muscle activities as an interface between machine hardware and human wetware, granting direct and natural control of our electronic peripherals. Regardless of the significant progression as of late, the conventional myographic sensors are still incapable of achieving the desired high-resolution and non-invasive recording.

View Article and Find Full Text PDF

Until recently, many countries' policies were motivated by economic growth; however, few strategies were developed to prevent environmental deterioration including reducing the ecological footprint. In this context, the purpose of this study was to analyze the role of natural resource rents, technological innovation, and financial development on the ecological footprint in 90 Belt and Road Initiative (BRI) economies. This research divided the BRI economies into high income, middle-income, and low-income levels to capture income differences.

View Article and Find Full Text PDF

Sonomyography refers to the measurement of muscle activity with an ultrasonic transducer. It is a candidate modality for applications in diagnosis of muscle conditions, rehabilitation engineering and prosthesis control as an alternative to electromyography. We propose a mechanically-flexible piezoelectric sonomyography transducer.

View Article and Find Full Text PDF

A Hall sensor array system for magnetic field detection and analysis is realized in X-FAB 0.18 μm CMOS technology. Magnetic field detection is attributed to the magnetization of metal coils to metal particles and the sensing characteristics of the Hall sensor array.

View Article and Find Full Text PDF

Integrated magnetic Hall effect sensors have been widely used in people's daily life over the past decades, and still are gaining enormous attention from researchers to establish novel applications, especially in biochemistry and biomedical healthcare. This paper reviews, classifies, compares and concludes state-of-the-art integrated Hall magnetic sensors in terms of cost, power, area, performance and application. Current applications of the Hall sensors such as detecting magnetic nanoparticles (MNPs) labeled on biomolecule, monitoring blood pulse wave velocity, characterizing soft biological materials, controlling syringe injection rate and eye surgery by training systems, and assisting magnetic resonance imaging (MRI) will be discussed comprehensively and future applications and trends will be highlighted.

View Article and Find Full Text PDF

Magnetomyography (MMG) is the measurement of magnetic signals generated in the skeletal muscle of humans by electrical activities. However, current technologies developed to detect such tiny magnetic field are bulky, costly and require working at the temperature-controlled environment. Developing a miniaturized, low cost and room temperature magnetic sensors provide an avenue to enhance this research field.

View Article and Find Full Text PDF

Magnetomyography (MMG) with superconducting quantum interference devices (SQUIDs) enabled the measurement of very weak magnetic fields (femto to pico Tesla) generated from the human skeletal muscles during contraction. However, SQUIDs are bulky, costly, and require working in a temperature-controlled environment, limiting wide-spread clinical use. We introduce a low-profile magnetoelectric (ME) sensor with analog frontend circuitry that has sensitivity to measure pico-Tesla MMG signals at room temperature.

View Article and Find Full Text PDF

Magnetomyography utilizes magnetic sensors to record small magnetic fields produced by the electrical activity of muscles, which also gives rise to the electromyogram (EMG) signal typically recorded with surface electrodes. Detection and recording of these small fields requires sensitive magnetic sensors possibly equipped with a CMOS readout system. This paper presents a highly sensitive Hall sensor fabricated in a standard $0.

View Article and Find Full Text PDF

The present full-angle, free-space fluorescence molecular tomography (FMT) system uses a step-by-step strategy to acquire measurements, which consumes time for both the rotation of the object and the integration of the charge-coupled device (CCD) camera. Completing the integration during the rotation is a more time-efficient strategy called synchronous data acquisition. However, the positions of sources and detectors in this strategy are not stationary, which is not taken into account in the conventional reconstruction algorithm.

View Article and Find Full Text PDF