Environ Sci Pollut Res Int
February 2024
This research determines the influence of green supply chain management practices (GSCM) on environmental performance. It also investigates the moderating role of supply chain environmental cooperation on GSCM practices and environmental performance relationships. A total of 370 employees of several Bangladeshi manufacturing companies were conveniently chosen as respondents.
View Article and Find Full Text PDFA crop simulation model is adopted to calculate the potential yield in a certain location. The data sets generated in each scenario (2021-2022) were used to evaluate the InfoCrop model. A field experiment using a randomized complete block design was conducted at the Agronomy Department's research field, Hajee Mohammad Danesh Science and Technology University.
View Article and Find Full Text PDFThe majority of data regarding tissue substrate for post myocardial infarction (MI) VT has been collected during hemodynamically tolerated VT, which may be distinct from the substrate responsible for VT with hemodynamic compromise (VT-HC). This study aimed to characterize tissue at diastolic locations of VT-HC in a porcine model. Late Gadolinium Enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging was performed in eight pigs with healed antero-septal infarcts.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2021
Aims: Left atrial (LA) remodelling is a common feature of many cardiovascular pathologies and is a sensitive marker of adverse cardiovascular outcomes. The aim of this study was to establish normal ranges for LA parameters derived from coronary computed tomographic angiography (CCTA) imaging using a standardised image processing pipeline to establish normal ranges in a previously described cohort.
Methods: CCTA imaging from 193 subjects recruited to the Budapest GLOBAL twin study was analysed.
Circ Cardiovasc Imaging
December 2020
Background: Pathological atrial fibrosis is a major contributor to sustained atrial fibrillation. Currently, late gadolinium enhancement (LGE) scans provide the only noninvasive estimate of atrial fibrosis. However, widespread adoption of atrial LGE has been hindered partly by nonstandardized image processing techniques, which can be operator and algorithm dependent.
View Article and Find Full Text PDFSegmentation of medical images, particularly late gadolinium-enhanced magnetic resonance imaging (LGE-MRI) used for visualizing diseased atrial structures, is a crucial first step for ablation treatment of atrial fibrillation. However, direct segmentation of LGE-MRIs is challenging due to the varying intensities caused by contrast agents. Since most clinical studies have relied on manual, labor-intensive approaches, automatic methods are of high interest, particularly optimized machine learning approaches.
View Article and Find Full Text PDFPurpose: A recent clinical trial has demonstrated that noninvasive radioablation (NIRA) has the potential to reduce recurrent ventricular tachycardia (VT) that is refractory to drugs and standard catheter ablation. Electroanatomic mapping (EAM) that would be useful for planning is obtained during catheter ablation, but incompatibility between EAM and DICOM formats required for radiation planning has impeded the use of existing catheter-based mapping to guide NIRA and is an important hurdle for its wider adoption. In this paper we define a process to facilitate the fusion of catheter-based EAM with DICOM imaging for radiation planning.
View Article and Find Full Text PDFJ Cardiovasc Magn Reson
February 2020
Background: Using cardiovascular magnetic resonance imaging (CMR), it is possible to detect diffuse fibrosis of the left ventricle (LV) in patients with atrial fibrillation (AF), which may be independently associated with recurrence of AF after ablation. By conducting CMR, clinical, electrophysiology and biomarker assessment we planned to investigate LV myocardial fibrosis in patients undergoing AF ablation.
Methods: LV fibrosis was assessed by T1 mapping in 31 patients undergoing percutaneous ablation for AF.
Aims: A point-by-point workflow for pulmonary vein isolation (PVI) targeting pre-defined Ablation Index values (a composite of contact force, time, and power) and minimizing interlesion distance may optimize the creation of contiguous ablation lesions whilst minimizing scar formation. We aimed to compare ablation scar formation in patients undergoing PVI using this workflow to patients undergoing a continuous catheter drag workflow.
Methods And Results: Post-ablation cardiovascular magnetic resonance imaging was performed in patients undergoing 1st-time PVI using a parameter-guided point-by-point workflow (n = 26).
Introduction: Multiple cardiac magnetic resonance (CMR)-derived indices of atrial fibrillation (AF) substrate have been shown in isolation to predict long-term outcome following catheter ablation. Left atrial (LA) fibrosis, LA volume, LA ejection fraction (EF), left ventricular ejection fraction (LVEF), LA shape (sphericity) and pulmonary vein anatomy have all been shown to correlate with late AF recurrence. This study aimed to validate and assess the relative contribution of multiple indices in a long-term single-center study.
View Article and Find Full Text PDFJACC Cardiovasc Imaging
October 2019
Annu Int Conf IEEE Eng Med Biol Soc
July 2018
The use of implantable cardiac devices has increased in the last 30 years. Cardiac resynchronisation therapy (CRT) is a procedure which involves implanting a coin sized pacemaker for reversing heart failure. The pacemaker electrode leads are implanted into cardiac myocardial tissue.
View Article and Find Full Text PDFIntroduction: The VisiTag module (CARTO3) provides an objective assessment of radiofrequency (RF) ablation parameters. This study aimed to determine the predictive value and optimal VisiTag threshold settings for prediction of gaps in mature atrial scar, as assessed non-invasively using cardiac magnetic resonance (CMR) imaging.
Methods: Twenty-four subjects (11 paroxysmal atrial fibrillation) underwent first-time RF ablation with operators blinded to VisiTag data.
Structural changes to the wall of the left atrium are known to occur with conditions that predispose to Atrial fibrillation. Imaging studies have demonstrated that these changes may be detected non-invasively. An important indicator of this structural change is the wall's thickness.
View Article and Find Full Text PDFJACC Clin Electrophysiol
August 2017
Biophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resulting biophysical models. In 7 patients, we recorded the atrial anatomy with an electroanatomical mapping system (St Jude Velocity); we then applied an S1-S2 electrical stimulation protocol from the coronary sinus (CS) and the high right atrium (HRA) whilst recording the activation patterns using a PentaRay catheter with 10 bipolar electrodes at 12 ± 2 sites across the atrium.
View Article and Find Full Text PDFBackground: Cardiovascular magnetic resonance (CMR) imaging may be used to visualize post-ablation atrial scar (PAAS), and three-dimensional late gadolinium enhancement (3D LGE) is the most widely employed technique for imaging of chronic scar. Detection of PAAS provides a unique non-invasive insight into the effects of the ablation and may help guide further ablation procedures. However, there is evidence that PAAS is often not detected by CMR, implying a significant sensitivity problem, and imaging parameters vary between leading centres.
View Article and Find Full Text PDFBackground: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation.
View Article and Find Full Text PDFAims: To test the ability of four circulating biomarkers of fibrosis, and of low left atrial voltage, to predict recurrence of atrial fibrillation after catheter ablation.
Background: Circulating biomarkers potentially may be used to improve patient selection for atrial fibrillation ablation. Low voltage areas in the left atrium predict arrhythmia recurrence when mapped in sinus rhythm.
J Interv Card Electrophysiol
October 2017
Purpose: Left atrial arrhythmia substrate assessment can involve multiple imaging and electrical modalities, but visual analysis of data on 3D surfaces is time-consuming and suffers from limited reproducibility. Unfold maps (e.g.
View Article and Find Full Text PDFIEEE Trans Med Imaging
November 2017
Patients with drug-refractory heart failure can greatly benefit from cardiac resynchronization therapy (CRT). A CRT device can resynchronize the contractions of the left ventricle (LV) leading to reduced mortality. Unfortunately, 30%-50% of patients do not respond to treatment when assessed by objective criteria such as cardiac remodeling.
View Article and Find Full Text PDFAims: Measurement of circulating biomarkers of fibrosis may have a role in selecting patients and treatment strategy for catheter ablation. Pro-collagen type III N-terminal pro-peptide (PIIINP), C-telopeptide of type I collagen (ICTP), fibroblast growth factor 23 (FGF-23), and galectin 3 (gal-3) have all been suggested as possible biomarkers for this indication, but studies assessing whether peripheral levels reflect intra-cardiac levels are scarce.
Methods And Results: We studied 93 patients undergoing ablation for paroxysmal atrial fibrillation (AF) (n = 63) or non-paroxysmal AF (n = 30).
IEEE Trans Biomed Eng
November 2016
This paper presents a novel MR-compatible 3-DOF cardiac catheter steering mechanism. The catheter's steerable structure is tendon driven and consists of miniature deflectable, helical segments created by a precise rapid prototyping technique. The created catheter prototype has an outer diameter of 9 Fr (3 mm) and a steerable distal end that can be deflected in a 3-D space via four braided high-tensile Spectra fiber tendons.
View Article and Find Full Text PDF