Publications by authors named "Paul-Henry Mackeprang"

This study aimed to show that table movement of dynamic trajectory radiotherapy (DTRT) does not induce more motion sickness than standard-of-care non-coplanar volumetric modulated arc therapy (ncVMAT). Forty-one healthy volunteers underwent dry-runs of DTRT and ncVMAT in four different, randomly allocated sequences. The primary outcome was the Motion Sickness Assessment Questionnaire (MSAQ) summary score.

View Article and Find Full Text PDF

Purpose: Robustness assessment is an essential part of radiotherapy plan quality assessment. However, it is often not evaluated in photon-based radiotherapy. This study aims to conduct a robustness audit to establish a baseline for the role of plan robustness in Switzerland by assessing and comparing robustness across plans from and clinical workflows in multiple institutions.

View Article and Find Full Text PDF

Background And Purpose: Dynamic trajectory radiotherapy (DTRT) has been shown to improve healthy tissue sparing compared to volumetric arc therapy (VMAT). This study aimed to assess and compare the robustness of DTRT and VMAT treatment-plans for head and neck (H&N) cancer to patient-setup (PS) and machine-positioning uncertainties.

Materials And Methods: The robustness of DTRT and VMAT plans previously created for 46 H&N cases, prescribed 50-70 Gy to 95 % of the planning-target-volume, was assessed.

View Article and Find Full Text PDF

We compared dynamic trajectory radiotherapy (DTRT) to state-of-the-art volumetric modulated arc therapy (VMAT) for 46 head and neck cancer cases. DTRT had lower dose to salivary glands and swallowing structure, resulting in lower predicted xerostomia and dysphagia compared to VMAT. DTRT is deliverable on C-arm linacs with high dosimetric accuracy.

View Article and Find Full Text PDF

Background: Intensity-modulated radiation therapy (IMRT) is considered standard of care for head and neck squamous cell carcinoma (HNSCC). Improved conformity of IMRT and smaller margins, however, have led to concerns of increased rates of marginal failures. We hypothesize that while patterns of failure (PoF) after IMRT for HNSCC have been published before, the quality of patient positioning and image guided radiotherapy (IGRT) have rarely been taken into account, and their importance remains unclear.

View Article and Find Full Text PDF

Background: Non-coplanar techniques have shown to improve the achievable dose distribution compared to standard coplanar techniques for multiple treatment sites but finding optimal beam directions is challenging. Dynamic collimator trajectory radiotherapy (colli-DTRT) is a new intensity modulated radiotherapy technique that uses non-coplanar partial arcs and dynamic collimator rotation.

Purpose: To solve the beam angle optimization (BAO) problem for colli-DTRT and non-coplanar VMAT (NC-VMAT) by determining the table-angle and the gantry-angle ranges of the partial arcs through iterative 4π fluence map optimization (FMO) and beam direction elimination.

View Article and Find Full Text PDF

. Electron arcs in mixed-beam radiotherapy (Arc-MBRT) consisting of intensity-modulated electron arcs with dynamic gantry rotation potentially reduce the delivery time compared to mixed-beam radiotherapy containing electron beams with static gantry angle (Static-MBRT). This study aims to develop and investigate a treatment planning process (TPP) for photon multileaf collimator (pMLC) based Arc-MBRT.

View Article and Find Full Text PDF

Background: Dynamic trajectory radiotherapy (DTRT) extends state-of-the-art volumetric modulated arc therapy (VMAT) by dynamic table and collimator rotations during beam-on. The effects of intrafraction motion during DTRT delivery are unknown, especially regarding the possible interplay between patient and machine motion with additional dynamic axes.

Purpose: To experimentally assess the technical feasibility and quantify the mechanical and dosimetric accuracy of respiratory gating during DTRT delivery.

View Article and Find Full Text PDF

Background: Dynamic trajectory radiotherapy (DTRT) extends volumetric modulated arc therapy (VMAT) with dynamic table and collimator rotation during beam-on. The aim of the study is to establish DTRT path-finding strategies, demonstrate deliverability and dosimetric accuracy and compare DTRT to state-of-the-art VMAT for common head and neck (HN) cancer cases.

Methods: A publicly available library of seven HN cases was created on an anthropomorphic phantom with all relevant organs-at-risk (OARs) delineated.

View Article and Find Full Text PDF

Background: Evaluating plan robustness is a key step in radiotherapy.

Purpose: To develop a flexible Monte Carlo (MC)-based robustness calculation and evaluation tool to assess and quantify dosimetric robustness of intensity-modulated radiotherapy (IMRT) treatment plans by exploring the impact of systematic and random uncertainties resulting from patient setup, patient anatomy changes, and mechanical limitations of machine components.

Methods: The robustness tool consists of two parts: the first part includes automated MC dose calculation of multiple user-defined uncertainty scenarios to populate a robustness space.

View Article and Find Full Text PDF

Proton therapy (PT) is delivered to complex brain tumors to obtain an optimal curative treatment with limited toxicity. Value-based oncological medicine is increasingly important, particularly when long-term survival is to be expected. This study aims to evaluate health-related quality of life (HRQOL) and patient reported outcomes (PROs) in patients treated with PT for brain tumors.

View Article and Find Full Text PDF

Background: In order to locate an arteriovenous malformation, typically, a digital subtraction angiography (DSA) is carried out. To use the DSA for target definition an accurate image registration between CT and DSA is required. Carrying out a non-invasive, frameless procedure, registration of the 2D-DSA images with the CT is critical.

View Article and Find Full Text PDF

Compared to a conventional linear accelerator, the Cyberknife (CK) is a unique system with respect to radiation protection shielding and the variety and number of non-coplanar beams are two key components regarding this aspect. In this work, a framework to assess the direction distribution and modulation factor (MF) of clinically applied treatment beams of a CyberKnife M6 is developed. Database filtering options allow studying the influence of different parameters such as collimator types, treatment sites or different bunker sizes.

View Article and Find Full Text PDF