Publications by authors named "Liang-Yu Li"

Article Synopsis
  • Global precipitation is intensifying because of climate change, prompting the need for advanced technology to manage water resources sustainably.
  • This research introduces a smart water control system using AI, featuring a combination of sensors for measuring water levels and quality, alongside an efficient low-cost IoT design.
  • The proposed system can cut costs by over 60% while improving measurement precision by more than 15%, aiming to conserve water resources effectively while addressing issues related to extreme weather events.
View Article and Find Full Text PDF
Article Synopsis
  • A clinical trial was conducted to compare gene-based dosing of 6-mercaptopurine (6-MP) to standard dosing in Chinese children with acute lymphoblastic leukemia (ALL), focusing on those with low- or intermediate-risk.
  • The gene-based dosing resulted in a 2.2-fold decrease in myelosuppression compared to standard dosing, using approximately half the standard dose, and significantly reduced the risk of leukopenia.
  • No major differences were found in hepatotoxicity or metabolite concentrations in the blood between the two treatment groups, suggesting that gene-based dosing may be a safer alternative for this patient population.
View Article and Find Full Text PDF

Due to the high demand of wearable electronics, flexible supercapacitors have been extensively developed in recent years. Yet, the effect of deformation in the interior electrode material suffered in practical applications on the performance received less attention. Here, we study the electrochemical behavior of macroscopic nanoporous gold/polypyrrole (NPG/PPy) in situ under compression deformation.

View Article and Find Full Text PDF

Objective: To evaluate the safety and efficacy of transnasal endoscopic resection and craniofacial resection through an external approach for olfactory neuroblastoma (ONB).

Methods: Thirty two patients with ONB treated between 1987 and 2006 were retrospectively reviewed.

Results: The patients were followed up for 8-135 months, the median follow-up time was 20 months.

View Article and Find Full Text PDF

Objective: To evaluate endoscopic ultrasonography for masses in nasal cavity and paranasal sinus.

Methods: Under the guidance of nasal endoscope, sonographic scan of 18 masses within nasal cavity and paranasal sinus was performed by using 10 MHz catheter transducer with diameter of 3.3 mm under local anesthesia.

View Article and Find Full Text PDF