Publications by authors named "Karlheinz Seidl"

Background: Asymptomatic nonvalvular atrial fibrillation is often suspected in patients with cryptogenic stroke which constitute 20%-30% of ischemic strokes. Detection of atrial fibrillation (AF) and treatment with anticoagulation can reduce the risk of stroke. We sought to investigate the prevalence of asymptomatic atrial fibrillation (aAF) in patients with a history of stroke or an acute stroke on admission.

View Article and Find Full Text PDF

(1) Background: The aim of our study was to identify specific risk factors for fatal outcome in critically ill COVID-19 patients. (2) Methods: Our data set consisted of 840 patients enclosed in the LEOSS registry. Using lasso regression for variable selection, a multifactorial logistic regression model was fitted to the response variable survival.

View Article and Find Full Text PDF

Aims: To assess the impact of the lockdown due to coronavirus disease 2019 (COVID-19) on key quality indicators for the treatment of ST-segment elevation myocardial infarction (STEMI) patients.

Methods: Data were obtained from 41 hospitals participating in the prospective Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction (FITT-STEMI) study, including 15,800 patients treated for acute STEMI from January 2017 to the end of March 2020.

Results: There was a 12.

View Article and Find Full Text PDF

Background: Optimal treatment of patients with persistent atrial fibrillation (AF) and heart failure (HF) with reduced left ventricular ejection fraction (LVEF) and an indication for internal defibrillator therapy is controversial.

Methods: Patients with persistent/longstanding persistent AF and LVEF ≤35% were randomly allocated to catheter ablation of AF or best medical therapy (BMT). The primary study end point was the absolute increase in LVEF from baseline at 1 year.

View Article and Find Full Text PDF

Background: In the present study, we have focused upon rates and clinical determinants of inappropriate shock (IS) after implantable cardioverter-defibrillator (ICD).

Methods: Data were collected prospectively in the German Device II Registry.

Results: A total of 783 patients were included.

View Article and Find Full Text PDF

According to current guidelines prophylactic implantable cardioverter-defibrillator (ICD) therapy is recommended in patients with significantly impaired left ventricular systolic function. However, the recently published DANISH trial did not find a significantly lower long-term rate of death from any cause compared with usual clinical care in patients with non-ischemic cardiomyopathy. We investigated whether registry data from a multi-center 'real-life' registry on patients with non-ischemic cardiomyopathy are similar to this trial.

View Article and Find Full Text PDF

Background: In heart failure (HF) patients with implantable cardioverter defibrillators (ICD) or cardiac resynchronisation therapy defibrillators (CRT-D), remote monitoring has been shown to result in at least non-inferior outcomes relative to in-clinic visits. We aimed to provide further evidence for this effect, and to assess whether adding telephone follow-ups to remote follow-ups influenced outcomes.

Methods: InContact was a prospective, randomised, multicentre study.

View Article and Find Full Text PDF

Aims: The aim of this study was to investigate the effect of contact-to-balloon time on mortality in ST-segment elevation myocardial infarction (STEMI) patients with and without haemodynamic instability.

Methods And Results: Using data from the prospective, multicentre Feedback Intervention and Treatment Times in ST-Elevation Myocardial Infarction (FITT-STEMI) trial, we assessed the prognostic relevance of first medical contact-to-balloon time in n = 12 675 STEMI patients who used emergency medical service transportation and were treated with primary percutaneous coronary intervention (PCI). Patients were stratified by cardiogenic shock (CS) and out-of-hospital cardiac arrest (OHCA).

View Article and Find Full Text PDF

Background: Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) has been popularized as a precious patients' management tool. We have investigated RM within the premises of a multicenter, prospective, real-world registry, i.e.

View Article and Find Full Text PDF

Introduction: Reliable detection and monitoring of atrial fibrillation (AF) is essential for accurate clinical decision making, which can now be done continuously with the introduction of implantable cardiac monitors (ICM) The DETECT AF study evaluated the performance of the Confirm DM2102 ICM (St. Jude Medical, St. Paul, MN, USA) to accurately detect and monitor AF.

View Article and Find Full Text PDF

Aims: To analyse the long-term safety of implantable cardioverter defibrillators (ICDs) in patients discharged within 24 h or after 2- 5-day hospitalization, respectively, after complication-free implantation, in circumstances of actual care.

Methods And Results: Patients in the multicentre, nationwide German DEVICE registry were contacted 12-15 months after their first ICD implantation or device replacement. Data were collected on complications, potential arrhythmic events, syncope, resuscitation, ablation procedures, cardiac events, hospitalizations, heart failure status, change of medication, and quality of life.

View Article and Find Full Text PDF

Aim: The aim of this study was to analyze the radiation usage in patients undergoing pulmonary vein isolation (PVI) in Germany and to evaluate the possibility to reduce radiation dose.

Methods And Results: A total of 6617 patients with atrial fibrillation (AF) from the German ablation registry and the FREEZEplus registry (control group), who underwent first PVI between 2007 and 2014, were analyzed. In the second step, the effect of optimized conventional fluoroscopy and optimized 3D mapping use was evaluated in 526 consecutive patients with AF who underwent first PVI at the Klinikum Ludwigshafen (optimized group) between 2007 and 2014.

View Article and Find Full Text PDF

Introduction: Catheter ablation of paroxysmal atrial fibrillation (PAF) has been suggested as first-line treatment for selected patients (pts). However, patient characteristics, procedural data, and complication rate in the group of young patients remain undetermined.

Methods: The German Ablation Registry has been designed as a multi-center prospective registry.

View Article and Find Full Text PDF

Introduction: Recent studies suggest a worse impact of inappropriate shock therapies on the outcome of patients with an implantable cardioverter-defibrillator (ICD). However, it is not known whether the worse impact is attributed to the ICD shock itself or due to the underlying heart disease. The aim of the study was to evaluate the impact of inappropriate ICD shocks on clinical outcome by comparing ICD shocks triggered by atrial fibrillation (AF) with shocks caused by lead failure.

View Article and Find Full Text PDF

Aims: Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure.

Methods And Results: Patients indicated for CRT were enrolled and received a quadripolar electrode lead and CRT-D device (Quartetmodel 1458Q and Promote Q; St Jude Medical, Sylmar, CA, USA).

View Article and Find Full Text PDF

Aims: Aim of this study is to evaluate reproducibility, consistency and the impact of moderate exercise workload on optimized PV and VV delays as determined by the IEGM-based QuickOpt™ method (St. Jude Medical), that was shown to produce hemodynamic performance similar to that obtained by echo-guided aortic VTI maximization.

Methods: Sixty patients with CRT-ICD (65 ± 9 years, 12% female, LVEF 28 ± 9%, 48% CAD and 52% DCM) were enrolled.

View Article and Find Full Text PDF

Purpose: The aim of the study was to evaluate the incidence of ventricular arrhythmia and clinical outcome in patients receiving a cardiac resynchronization therapy (CRT) depending on the left ventricular (LV) lead position.

Methods: A total of 187 consecutive patients with advanced heart failure who received a CRT-implantable cardioverter defibrillator were analyzed. Forty patients (21%) had a LV lead in the anterior/apical (anterior) and 147 patients (79%) in the posterior/posterolateral (posterior) region.

View Article and Find Full Text PDF

Background: The aim of this study was to investigate the value of transesophageal echocardiography (TEE)-guided cardioversion (CV) to prevent thromboembolic complications in patients with short-term atrial fibrillation (AF) < 48 hours in duration.

Methods: This single-center, observational study comprised 366 consecutive, unselected patients with short-term AF < 48 hours in duration. During the first 2 years, CV was performed using the conventional approach without TEE.

View Article and Find Full Text PDF

Aims: This study was designed to evaluate the prevalence of bacterial colonization of generator pockets in implantable cardioverter defibrillator (ICD) patients without signs of infection and to analyse the impact of bacterial colonization on the incidence of device infection during follow-up.

Methods And Results: In 122 ICD patients undergoing generator replacement or surgical lead revision between January 2006 and July 2008, microbiological cultures of generator pockets and extracted leads were consecutively obtained. Patients with clinical evidence of a device infection were excluded.

View Article and Find Full Text PDF

Background: The rate of death, including sudden cardiac death, is highest early after a myocardial infarction. Yet current guidelines do not recommend the use of an implantable cardioverter-defibrillator (ICD) within 40 days after a myocardial infarction for the prevention of sudden cardiac death. We tested the hypothesis that patients at increased risk who are treated early with an ICD will live longer than those who receive optimal medical therapy alone.

View Article and Find Full Text PDF

Background: In the year 2000 a new definition of acute myocardial infarction (AMI) was introduced, now differentiating ST segment elevation AMI (STEMI) from non-ST segment elevation AMI (NSTEMI). The characterization of AMI patients according to this definition is still incomplete.

Methods And Results: 888 consecutive AMI patients at a single interventional center were included: 493 (55.

View Article and Find Full Text PDF

Background: All current cardiac resynchronization therapy (CRT) devices allow the programming of the atrioventricular (AV/PV) delays and the sequential stimulation of the ventricles via the inter ventricular (VV) delay.

Aim: This post hoc analysis of the RHYTHM II study was conducted to compare the reverse remodeling associated with VV delay optimization in patients randomly assigned to simultaneous (SIM) biventricular stimulation versus patients assigned to optimized VV delay programming (OPT) (1:3 randomization scheme).

Methods: The analysis included 14 patients assigned to the SIM group and 34 patients to the OPT group who completed the 6-month follow-up period with paired echocardiographic recordings.

View Article and Find Full Text PDF

Aims: To evaluate the prevalence and clinical impact of left atrial (LA) thrombus and dense spontaneous echo contrast (SEC) in patients with atrial fibrillation (AF) and low CHADS(2) score undergoing cardioversion.

Methods And Results: A total of 295 consecutive patients with non-valvular AF and a CHADS(2) score of 0 or 1 from the prospective single-centre registry ANTIK, who underwent transoesophageal echocardiography before cardioversion, were included in the study. Median follow-up was 5 years.

View Article and Find Full Text PDF

Background: Both left bundle branch block and right bundle branch block (RBBB) have been associated with increased inhospital and long-term mortality in patients with acute ST elevation myocardial infarction (STEMI). However, the prognostic role of RBBB in acute non-ST elevation myocardial infarction (NSTEMI) is not well known. Therefore, the aim of the study was to evaluate the incidence and clinical impact of RBBB in patients with NSTEMI compared to patients with STEMI.

View Article and Find Full Text PDF