Helium is a critical, scarce, and strategic resource, often found in association with natural gas. This study reports the first discovery of overpressured helium-rich natural gas in the Lower Yangtze Region of Eastern China, with helium concentrations reaching as high as 4.5%, significantly surpassing the commercial extraction threshold of 0.
View Article and Find Full Text PDFA foreign body retained in soft tissue may give rise to infection and dysfunction, which may pose a potential threat to patient health. Our study is to compare the efficacy and characteristics of metallic foreign body (MFB) extraction from soft tissue by incision surgery and x-ray-guided forceps after body surface projection positioning.This study enrolled 775 patients who underwent percutaneous MFB extraction between January 2011 and December 2016.
View Article and Find Full Text PDFMetamorphic zircon from a hornblendite in the South China Block (SCB) yield U-Pb age of 533 ± 7 Ma and Hf model ages from 900 to 1200 Ma. Geochemical and isotopic characteristics indicate that primary magma of the hornblendites was probably derived from an enriched asthenospheric mantle source. This Late Neoproterozoic-Cambrian (Pan-African) metamorphic event provides the first direct evidence that the SCB was an integral part of the Gondwana assembly.
View Article and Find Full Text PDFObjective: To analyse the clinical efficacy of surface projection in the localization and removal of metal foreign bodies using CT scan.
Methods: Total 795 cases with 1008 metal foreign bodies were treated at our hospital in 2012. Pre-operative surface projection was performed to localize foreign bodies in patients under the guidance of CT scan.
Cardiovasc Intervent Radiol
October 2015
Objective: To describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.
Methods: Under fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB.
Zircons are crucial to understanding the first 500 Myr of crustal evolution of Earth. Very few zircons of this age (>4050 Ma) have been found other than from a ~300 km diameter domain of the Yilgarn Craton, Western Australia. Here we report SIMS U-Pb and O isotope ratios and trace element analyses for two ~4100 Ma detrital zircons from a Paleozoic quartzite at the Longquan area of the Cathaysia Block.
View Article and Find Full Text PDFKorean J Radiol
September 2013
Objective: To investigate the value of 3-dimensional (3D) CT virtual anatomy imaging (VAI) in the complex foreign body (FB) retrieval of the soft tissues.
Materials And Methods: Four hundred and seventy-five patients with radiopaque FB(s) diagnosed by radiograph underwent contrast-enhanced 3D CT examination. VAI was reconstructed by volume-rendering opacity software, by sliding down the lowest threshold from -600 to 100 HU.
Background: We studied methods of locating metallic foreign bodies in soft tissue of the human body.
Methods: Using a three-dimensional (3D) locator, we removed metallic foreign bodies precisely from soft tissue of 7390 patients through magnetic forceps between June 1999 and June 2009.
Results: In 7390 patients, we successfully removed 99.