Expert Rev Med Devices
April 2022
Introduction: Mobile health (mHealth) solutions in atrial fibrillation (AF) are becoming widespread, thanks to everyday life devices, such as smartphones. Their use is validated both in monitoring and in screening scenarios. In the published literature, the diagnostic accuracy of mHealth solutions wide differs, and their current clinical use is not well established in principal guidelines.
View Article and Find Full Text PDFAims: The 4S-AF classification scheme comprises of four domains: stroke risk (St), symptoms (Sy), severity of atrial fibrillation (AF) burden (Sb), and substrate (Su). We sought to examine the implementation of the 4S-AF scheme in the EORP-AF General Long-Term Registry and compare outcomes in AF patients according to the 4S-AF-led decision-making process.
Methods And Results: Atrial fibrillation patients from 250 centres across 27 European countries were included.
Int J Cardiol
June 2022
Aims: Sudden cardiac death (SCD) causes high mortality and substantial societal burdens for healthcare systems (HSs). The risk of SCD is significantly increased in patients with reduced left ventricular ejection fraction after myocardial infarction (MI). Current guidelines recommend re-evaluation of cardioverter-defibrillator implantation 40 days post-MI, earliest.
View Article and Find Full Text PDFIn young patients, especially with no traditional coronary risk factors, hypercoagulable states may always be considered as an alternative cause of acute coronary syndromes. The concomitant thrombotic and bleeding risk associated with myeloproliferative disorders complicates the decision-making, particularly regarding long-term dual antiplatelet therapy. The chosen therapy may need to be frequently revisited, depending on the patient's bleeding complications.
View Article and Find Full Text PDFBackground: Atrial high rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) may be associated with a risk of progression towards long-lasting episodes (≥24 h) and clinical atrial fibrillation (AF).
Methods: Consecutive CIED patients presenting AHRE (with confirmation of an arrhythmia lasting 5 min-23 h 59 min, atrial rate ≥175/min, with no AF at 12-lead ECG and no prior clinical AF) were retrospectively enrolled. The aims of this study were to describe patients' characteristics and the incidence of adverse events, and second, to identify potential predictors of the composite outcome of clinical AF and/or AHRE episodes lasting ≥24 h.
Eur J Clin Invest
July 2022
Background: The management of patients with atrial fibrillation (AF) and malignancy is challenging given the paucity of evidence supporting their appropriate clinical management.
Purpose: To evaluate the outcomes of patients with active or prior malignancy in a contemporary cohort of European AF patients.
Methods: Patients enrolled in the EURObservational Research Programme in AF General Long-Term Registry were categorized into 3 categories: No Malignancy (NoMal), Prior Malignancy (PriorMal) and Active Malignancy (ActiveMal).
Arrhythmias (ARs) are potential cardiovascular complication of COVID-19 but may also have a prognostic role. The aim of this study was to explore the prevalence and impact of cardiac ARs in hospitalized COVID-19 patients. All-comer patients admitted to the emergency department of Modena University Hospital from 16 March to 31 December 2020 and diagnosed with COVID-19 pneumonia infection were included in the study.
View Article and Find Full Text PDFEuropace
April 2022
Background Guideline recommendations are the accepted reference for selection of therapies for rhythm control of atrial fibrillation (AF). This study was designed to understand physicians' treatment practices and adherence to guidelines. Methods and Results The AIM-AF (Antiarrhythmic Medication for Atrial Fibrillation) study was an online survey of clinical cardiologists and electrophysiologists that was conducted in the United States and Europe (N=629).
View Article and Find Full Text PDFCardiac implantable electronic device (CIED) implants and electrophysiological procedures share a common step: vascular access. On behalf of the AIAC Ricerca Investigators' Network, we conducted a survey to outline Italian common practice regarding vascular access in EP-lab. All Italian physicians with experience in CIED implantation and electrophysiology were invited to answer an online questionnaire (from May 2020 to November 2020) featuring 20 questions.
View Article and Find Full Text PDFBackground: Cardiac troponins (cTn) have been reported to be predictors for adverse outcomes in atrial fibrillation (AF), patients, but their actual use is still unclear.
Aim: To assess the factors associated with cTn testing in routine practice and evaluate the association with outcomes.
Methods: Patients enrolled in the ESC-EHRA EORP-AF General Long-Term Registry were stratified into 3 groups according to cTn levels as (i) cTn not tested, (ii) cTn in range (≤99th percentile), (iii) cTn elevated (>99th percentile).
J Interv Card Electrophysiol
September 2022
Purpose: Relatively few data are available on long-term survival and incidence of ventricular arrhythmias in cardiac resynchronization therapy (CRT) patients. We investigated long-term outcomes of CRT patients with non-ischemic dilated cardiomyopathy stratified as responders or non-responders according to radionuclide angiography.
Methods: Fifty patients with non-ischemic dilated cardiomyopathy undergoing CRT were assessed by equilibrium Tc radionuclide angiography with bicycle exercise at baseline and after 3 months.
Background: This paper aims to evaluate the concordance between the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) formula and alternative equations and to assess their predictive power for all-cause mortality in unselected patients discharged alive from a cardiology ward.
Methods: We retrospectively included patients admitted to our Cardiology Division independently of their diagnosis. The total population was classified according to Kidney Disease: Improving Global Outcomes (KDIGO) categories, as follows: G1 (estimated glomerular filtration rate (eGFR) ≥90 mL/min/1.
Expert Rev Med Devices
February 2022
Introduction: Remote monitoring (RM) of cardiac implantable electronic devices (CIED) allows rapid detection of clinical and electrical events. Recently, several smartphone applications have been developed with the aim of improving patient compliance and better interpreting and integrating data deriving from remote control for the management of heart failure (HF).
Areas Covered: Studies investigating the role of CIEDs' RM in HF patients to predict and early treat acute decompensation.
Circulation
February 2022
Growing evidence suggests a consistent association between atrial fibrillation (AF) and cognitive impairment and dementia that is independent of clinical stroke. This report from the AF-SCREEN International Collaboration summarizes the evidence linking AF to cognitive impairment and dementia. It provides guidance on the investigation and management of dementia in patients with AF on the basis of best available evidence.
View Article and Find Full Text PDFBackground: The incidence of infections associated with cardiac implantable electronic devices (CIEDs) and patient outcomes are not fully known.
Aim: To provide a contemporary assessment of the risk of CIEDs infection and associated clinical outcomes.
Methods: In Italy, 18 centres enrolled all consecutive patients undergoing a CIED procedure and entered a 12-months follow-up.
Background: Atrial fibrillation (AF) and renal impairment share a bidirectional relationship with important pathophysiological interactions. We evaluated the impact of renal impairment in a contemporary cohort of patients with AF.
Methods: We utilised the ESC-EHRA EORP-AF Long-Term General Registry.
J Cardiovasc Med (Hagerstown)
February 2022
J Cardiovasc Pharmacol
April 2022
No data on the add-on sacubitril/valsartan (S/V) therapy among cardiac resynchronization therapy with a defibrillator (CRT-D) nonresponder patients are currently available in literature. We conducted a prospective observational study including 190 CRT-D nonresponder patients with symptomatic heart failure with reduced ejection fraction despite the optimal medical therapy from at least 1 year. The primary endpoint was the rate of additional responders (left ventricular end-systolic volume reduction >15%) at 12 months from the introduction of S/V therapy.
View Article and Find Full Text PDFPacing Clin Electrophysiol
February 2022
Cardiac implantable electronic device (CIED) infection represents a dramatic event with a high mortality rate (>3x) despite antibiotic therapy and device extraction; therefore, the real winning strategy in this situation could be represented by prevention. Antibiotic prophylaxis and antibiotic-releasing envelope are effective in improving patient outcome; however, healthcare costs related to CIED infections remain high over the years. In this review we would keep the attention on a pre-surgical checklist to reduce the risk of CIED infections.
View Article and Find Full Text PDF