Background: Novel ablation catheters with mini electrode (ME) sensing have become available but their utility is unclear. We investigated whether ablation of the cavotricuspid isthmus (CTI) for atrial flutter (AFL) would be improved using ME signals.
Methods: Sixty-one patients (76% male, 63 ± 10 years) with CTI-dependent AFL underwent ablation using a maximum voltage-guided approach, randomized to either standard 8 mm non-irrigated catheter with bipolar signals or IntellaTip MiFi catheter using ME signals alone.
Heart Lung Circ
January 2022
Importance: Syncope is a common presentation to emergency departments, and cardiac and neurological aetiologies are the predominant causes. Ictal asystole is a rare cardio-neural phenomenon seen in epilepsy syndromes whereby a seizure causes asystole (≥3 s) leading to syncope.
Observations: We present three cases of ictal asystole, together with a narrative review of the literature to assess the prevalence of the condition and review the pathophysiology, diagnosis and management.
Background: Chronic right ventricular pacing may contribute to deterioration in left ventricular ejection fraction (LVEF). The aim of the study was to identify the prevalence of pacing-induced cardiomyopathy (PICM) in patients with chronic right ventricular pacing.
Methods: Patients attending a pacemaker clinic were retrospectively identified as having had transthoracic echocardiographic LVEF measurement during the 12 months prior to device implantation.
Expert Rev Cardiovasc Ther
March 2018
Cardiac resynchronization therapy (CRT) is one of the most important advances in heart failure management in the last twenty years. Approximately one-third of patients appear not to respond to therapy. Although there are a number of possible mechanisms for non-response, an important factor is suboptimal atrioventricular (AV) and interventricular (VV) timing intervals.
View Article and Find Full Text PDFBackground: Anticoagulation prior to elective external direct current cardioversion (EDCCV) is mandatory. The inability to monitor compliance with novel oral anticoagulants (NOACs) raises a potential safety issue. We aimed to evaluate whether a structured, nurse-led assessment of compliance prior to EDCCV ensures safety without the need for routine transoesophageal echocardiography (TOE).
View Article and Find Full Text PDFHeart Lung Circ
November 2017
Background: Cardiac sarcoidosis (CS) is an uncommon and under-recognised disease which most frequently presents with atrioventricular (AV) block and may also present with ventricular arrhythmias and left ventricular (LV) systolic dysfunction. Because of its protean clinical manifestations, confirming a diagnosis of CS is often challenging.
Methods: We report two cases where patients presented with atrioventricular (AV) block without evidence of underlying myocardial disease, underwent chronic dual-chamber pacing, and presented several years later with severe LV systolic dysfunction.
Eur Heart J Cardiovasc Imaging
May 2017
Pacing Clin Electrophysiol
May 2017
Background: Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG.
View Article and Find Full Text PDFPacing Clin Electrophysiol
September 2017
Chronic right ventricular (RV) apical pacing may lead to the development of heart failure in some patients. Although pacing of the RV septum has been proposed as an alternative, positioning a lead in the true septum has proven challenging. In addition to fluoroscopy at implant, it has been suggested that 12-lead surface electrocardiogram (ECG) can be used to determine septal lead position; however, studies show this may be inaccurate.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2016
Introduction: This study sought to investigate specific contact force (CF) parameters to guide cavotricuspid isthmus (CTI) ablation and compare the outcome with a historical control cohort.
Methods And Results: Patients (30) undergoing CTI ablation were enrolled prospectively in the Study cohort and compared with a retrospective Control cohort of 30 patients. Ablation in the Study cohort was performed using CF parameters >10 g and <40 g and a Force Time Integral (FTI) of 800 ± 10 g.
Indian Pacing Electrophysiol J
March 2016
Pacing Clin Electrophysiol
April 2016
Background: Right ventricular nonapical (RVNA) pacing may reduce the risk of heart failure. Fluoroscopy is the standard approach to determine lead tip position, but is inaccurate. We compared cardiac computed tomography (CT), magnetic resonance imaging (MRI), two-dimensional and three-dimensional transthoracic echocardiography (TTE), and chest x-ray (CXR) to assess which provides the optimal assessment of right ventricular (RV) lead tip position.
View Article and Find Full Text PDFBackground: The right ventricular apex (RVA) is the traditional lead site for chronic pacing but in some patients may cause impaired left ventricular (LV) systolic function over time. Comparisons with right ventricular nonapical (RVNA) pacing sites have generated inconsistent results and recent meta-analyses have demonstrated unclear benefit due to heterogeneity across studies.
Methods And Results: A systematic search for randomized controlled trials that compared LV ejection fraction (LVEF) outcomes between RVNA and RVA pacing was performed up to October 2014.
Background: Implantable cardioverter defibrillator (ICD) leads have traditionally been placed at the right ventricular apex (RVA). An important minority of patients with an ICD may develop a future requirement for bradycardia support. Pacing from the RVA may be detrimental, promoting heart failure and mortality.
View Article and Find Full Text PDFAim: Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period.
View Article and Find Full Text PDFBackground: Traditionally the provision of elective external direct current cardioversion (EDCCV) for patients with atrial arrhythmias has been doctor-led. Increasing demands on hospital beds and time pressures for doctors has driven the desire for an alternative approach. We established a nurse-led cardioversion service in 2006 and present our experience.
View Article and Find Full Text PDFIntroduction: Amiodarone is a widely used anti-arrhythmic drug. A common long-term complication is amiodarone-induced thyrotoxicosis (AIT). We examined retrospectively the efficacy of anti-thyroid drugs with or without prednisolone and the role of surgical thyroidectomy in the treatment of AIT in a single centre, in an iodine-replete region of Australia.
View Article and Find Full Text PDFAustralas Med J
March 2013
Lamin A/C gene-related cardiomyopathy is associated with progressive heart failure and malignant arrhythmias. Current guidelines advise the use of implantable defibrillators to prevent arrhythmogenic sudden cardiac death only in situations where there is evidence of severe left ventricular dysfunction. We describe a case of a woman with genetically confirmed Lamin C deficiency with preserved left ventricular function in whom an implantable defibrillator was inserted and within a month of implantation was used to terminate symptomatic ventricular tachycardia.
View Article and Find Full Text PDFThe prevalence of atrial fibrillation (AF) in patients with heart failure (HF) is high, but longitudinal studies suggest that the incidence of AF is relatively low. The authors investigated this paradox prospectively in an epidemiologically representative population of patients with HF and persistent AF. In all, 891 consecutive patients with HF [mean age, 70+/-10 years; 70% male; left ventricular ejection fraction, 32%+/-9%] were enrolled.
View Article and Find Full Text PDFDespite being a relatively common medical condition, sudden cardiac death suffers a widespread lack of knowledge and understanding among general physicians. This article fills this knowledge gap, outlining risk factors, causes and preventative strategies.
View Article and Find Full Text PDFBackground: Beta-blockers are effective for the treatment of heart failure, but their mechanism of action is unresolved. Heart rate reduction may be a central mechanism or a troublesome side effect.
Methods: A randomized, double-blind, parallel group study comparing chronic higher-rate (80 pulses per minute) with lower-rate (60 pulses per minute) pacing in pacemaker-dependent patients with symptomatic left ventricular (LV) systolic dysfunction, receiving beta-blockers.
Aims: External direct current cardioversion is an effective method of restoring sinus rhythm (SR) in patients with persistent atrial arrhythmias. Increasing demand for hospital beds, together with a reduction in junior doctors' hours, has adversely affected cardioversion provision. A regular nurse-led cardioversion service conducted in a dedicated hospital day-unit was introduced to resolve these constraints.
View Article and Find Full Text PDFPacing Clin Electrophysiol
May 2004
The use of implantable cardioverter defibrillator (ICD) in the management of malignant ventricular arrhythmia is well established. Radiation treatment is common in malignant neoplasms, but the direct effect of irradiation in ICD is largely not well understood. We describe a case where radiation treatment probably led to shock coil failure.
View Article and Find Full Text PDF