Publications by authors named "Eric D Morris"

Purpose: We aimed to demonstrate the clinical feasibility and safety of simulation-free hippocampal avoidance whole brain radiation therapy (HA-WBRT) in a pilot study (National Clinical Trial 05096286).

Methods And Materials: Ten HA-WBRT candidates were enrolled for treatment on a commercially available computed tomography (CT)-guided linear accelerator with online adaptive capabilities. Planning structures were contoured on patient-specific diagnostic magnetic resonance imaging (MRI), which were registered to a CT of similar head shape, obtained from an atlas-based database (AB-CT).

View Article and Find Full Text PDF

Background: Patients with inflammatory bowel disease (IBD) are at increased risk of herpes zoster (HZ). We evaluated the incidence of HZ in ulcerative colitis (UC) and Crohn's disease (CD) patients and compared this with HZ incidence in a non-IBD population.

Methods: We conducted a retrospective cohort study (GSK study identifier: VEO-000043) of adults aged ≥18 years with UC and CD and without IBD who were identified from claims recorded in a US healthcare database between October 2015 and February 2020.

View Article and Find Full Text PDF

Artificial intelligence (AI) has great potential to transform the clinical workflow of radiotherapy. Since the introduction of deep neural networks, many AI-based methods have been proposed to address challenges in different aspects of radiotherapy. Commercial vendors have started to release AI-based tools that can be readily integrated to the established clinical workflow.

View Article and Find Full Text PDF

Aims: Use of comprehensive genomic profiling (CGP) in metastatic colorectal cancer (mCRC) is limited. We estimated impacts of expanded 1 L CGP, using the Tempus xT test, on detection of actionable alterations and testing budgets in a modeled US health plan over two-years.

Materials And Methods: A decision analytic model was developed to estimate the impact of replacing 20% of usual testing (a mix of CGP and non-CGP) with Tempus xT CGP.

View Article and Find Full Text PDF

Purpose: Whole-heart dose metrics are not as strongly linked to late cardiac morbidities as radiation doses to individual cardiac substructures. Our aim was to characterize the excursion and dosimetric variation throughout respiration of sensitive cardiac substructures for future robust safety margin design.

Methods And Materials: Eleven patients with cancer treatments in the thorax underwent 4-phase noncontrast 4-dimensional computed tomography (4DCT) with T2-weighted magnetic resonance imaging in end-exhale.

View Article and Find Full Text PDF

This study reports the initial results for the first 15 patients on a prospective phase II clinical trial exploring the safety, feasibility, and efficacy of the HyperArc technique for recurrent head and neck cancer treatment. Eligible patients were simulated and planned with both conventional VMAT and HyperArc techniques and the plan with superior dosimetry was selected for treatment. Dosimetry, delivery feasibility and safety, treatment-related toxicity, and patient-reported quality of life (QOL) were all evaluated.

View Article and Find Full Text PDF

Purpose: Patient tolerability of magnetic resonance (MR)-guided radiation treatment delivery is limited by the need for repeated deep inspiratory breath holds (DIBHs). This volunteer study assessed the feasibility of continuous positive airway pressure (CPAP) with and without DIBH for respiratory motion management during radiation treatment with an MR-linear accelerator (MR-linac).

Methods And Materials: MR imaging safety was first addressed by placing the CPAP device in an MR-safe closet and configuring a tube circuit via waveguide to the magnet bore.

View Article and Find Full Text PDF

Purpose: Accurate and robust auto-segmentation of highly deformable organs (HDOs), for example, stomach or bowel, remains an outstanding problem due to these organs' frequent and large anatomical variations. Yet, time-consuming manual segmentation of these organs presents a particular challenge to time-limited modern radiotherapy techniques such as on-line adaptive radiotherapy and high-dose-rate brachytherapy. We propose a machine-assisted interpolation (MAI) that uses prior information in the form of sparse manual delineations to facilitate rapid, accurate segmentation of the stomach from low field magnetic resonance images (MRI) and the bowel from computed tomography (CT) images.

View Article and Find Full Text PDF
Article Synopsis
  • Emerging evidence indicates that cardiac substructures are particularly vulnerable to radiation during cancer treatment, highlighting the need to understand their positional variability.
  • The study involved 18 patients undergoing radiotherapy for intrathoracic tumors, using MRI to track daily shifts in their cardiac substructures with a focus on accuracy achieved through advanced imaging techniques.
  • Results showed significant inter-fraction displacements in various cardiac components, with recommendations for substructure-specific safety margins to enhance cardiac protection during radiation therapy, warranting further validation in larger studies.
View Article and Find Full Text PDF

Purpose: Rising evidence suggests that cardiac substructures are highly radiosensitive. However, they are not routinely considered in treatment planning as they are not readily visualized on treatment planning CTs (TPCTs). This work integrated the soft tissue contrast provided by low-field MRIs acquired on an MR-linac via image registration to further enable cardiac substructure sparing on TPCTs.

View Article and Find Full Text PDF

Purpose: Radiation dose to cardiac substructures is related to radiation-induced heart disease. However, substructures are not considered in radiation therapy planning (RTP) due to poor visualization on CT. Therefore, we developed a novel deep learning (DL) pipeline leveraging MRI's soft tissue contrast coupled with CT for state-of-the-art cardiac substructure segmentation requiring a single, non-contrast CT input.

View Article and Find Full Text PDF

Model-based iterative reconstruction (MBIR) reduces CT imaging dose while maintaining image quality. However, MBIR reduces noise while preserving edges which may impact intensity-based tasks such as auto-segmentation. This work evaluates the sensitivity of an auto-contouring prostate atlas across multiple MBIR reconstruction protocols and benchmarks the results against filtered back projection (FBP).

View Article and Find Full Text PDF

Purpose: Radiation dose to the heart and cardiac substructures has been linked to cardiotoxicities. Because cardiac substructures are poorly visualized on treatment-planning computed tomography (CT) scans, we used the superior soft-tissue contrast of magnetic resonance (MR) imaging to optimize a hybrid MR/CT atlas for substructure dose assessment using CT.

Methods And Materials: Thirty-one patients with left-sided breast cancer underwent a T2-weighted MR imaging scan and noncontrast simulation CT scans.

View Article and Find Full Text PDF

Purpose: This work characterizes a novel exponential 4DCT reconstruction algorithm (EXPO), in phantom and patient, to determine its impact on image quality as compared to the standard cosine-squared weighted 4DCT reconstruction.

Methods: A motion platform translated objects in the superior-inferior (S-I) direction at varied breathing rates (8-20 bpm) and couch pitches (0.06-0.

View Article and Find Full Text PDF

Purpose: Recent advancements in synthetic computed tomography (synCT) from magnetic resonance (MR) imaging data have made MRI-only treatment planning feasible in the brain, although synCT performance for image guided radiation therapy (IGRT) is not well understood. This work compares geometric equivalence of digitally reconstructed radiographs (DRRs) from CTs and synCTs for brain cancer patients and quantifies performance for partial brain IGRT.

Methods And Materials: Ten brain cancer patients (12 lesions, 7 postsurgical) underwent MR-SIM and CT-SIM.

View Article and Find Full Text PDF