Purpose: The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy.
Material And Methods: The coverage with dosimetric concordance index (CDCI) is expressed as CDCI and CDCI. The CDCI is the mean coverage of target volume with common volume irradiated by prescription dose among all observers and represents the condition of worst target coverage.
Radiother Oncol
October 2018
Purpose: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy.
Methods: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN).
Brachytherapy
April 2018
Purpose: To investigate the change of clinical target volume (CTV) and its dosimetric impact during the course of accelerated partial breast irradiation (APBI) using intraoperative multicatheter interstitial brachytherapy after open cavity surgery.
Methods And Materials: Twenty-two patients of APBI with intraoperative placement of catheters underwent computed tomography scans for the treatment planning before the first (CT1) and the last (CT2) treatment fraction. Delineation of lumpectomy cavity and CTV was done consistently on both CT data sets by one of the coauthors.
J Contemp Brachytherapy
April 2017
Purpose: To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy.
Material And Methods: Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient.
Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates.
View Article and Find Full Text PDFCavity theory is fundamental to understanding and predicting dosimeter response. Conventional cavity theories have been shown to be consistent with one another by deriving the electron (+positron) and photon fluence spectra with the FLURZnrc user-code (EGSnrc Monte-Carlo system) in large volumes under quasi-CPE for photon beams of 1 MeV and 10 MeV in three materials (water, aluminium and copper) and then using these fluence spectra to evaluate and then inter-compare the Bragg-Gray, Spencer-Attix and 'large photon' 'cavity integrals'. The behaviour of the 'Spencer-Attix dose' (aka restricted cema), D S-A(▵), in a 1-MeV photon field in water has been investigated for a wide range of values of the cavity-size parameter ▵: D S-A(▵) decreases far below the Monte-Carlo dose (D MC) for ▵ greater than ≈ 30 keV due to secondary electrons with starting energies below ▵ not being 'counted'.
View Article and Find Full Text PDFThe adequacy of setup margins for various sites in patients treated with helical tomotherapy was investigated. A total of 102 patients were investigated. The breakdown of the patients were as follows: Twenty-five patients each in brain, head and neck (H and N), and pelvis, while 12 patients in lung and 15 in craniospinal irradiation (CSI).
View Article and Find Full Text PDFTo compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI).
View Article and Find Full Text PDFPurpose: To compare the dose accumulation for bladder and rectum by deformable image registration (DIR) and direct addition (DA) of dose volume histogram parameters in magnetic resonance image-guided adaptive brachytherapy (IGABT). Two DIR algorithms, contour- and intensity-based, also have been analyzed.
Methods And Materials: Patients (n = 21) treated with IGABT for carcinoma cervix under the IntErnational study on MRI-guided BRachytherapy in locally Advanced CErvical cancer protocol were analyzed.
Aim: The present study was to investigate the use of MOSFET as an vivo dosimeter for the application of Ir-192 HDR brachytherapy treatments.
Material And Methods: MOSFET was characterized for dose linearity in the range of 50-1000 cGy, depth dose dependence from 2 to 7 cm, angular dependence. Signal fading was checked for two weeks.
In small photon fields ionisation chambers can exhibit large deviations from Bragg-Gray behaviour; the EGSnrc Monte Carlo (MC) code system has been employed to investigate this 'Bragg-Gray breakdown'. The total electron (+positron) fluence in small water and air cavities in a water phantom has been computed for a full linac beam model as well as for a point source spectrum for 6 MV and 15 MV qualities for field sizes from 0.25 × 0.
View Article and Find Full Text PDFThe relationships between D, K and Kcol are of fundamental importance in radiation dosimetry. These relationships are critically influenced by secondary electron transport, which makes Monte-Carlo (MC) simulation indispensable; we have used MC codes DOSRZnrc and FLURZnrc. Computations of the ratios D/K and D/Kcol in three materials (water, aluminum and copper) for large field sizes with energies from 50 keV to 25 MeV (including 6-15 MV) are presented.
View Article and Find Full Text PDFIndian J Crit Care Med
September 2014
Background And Aims: With the expanding use of diagnostic and therapeutic radiological modalities in critically ill patients, doctors working in Intensive Care Units (ICUs) are increasingly exposed to ionizing radiation. This risk of radiation exposure occurs not only during bedside radiologic procedures, but also when ICU physicians accompany patients to radiology suites. The aim of this study was to quantify levels of radiation exposure among medical professionals working in the ICU.
View Article and Find Full Text PDFJ Med Phys
January 2014
The objective of this study was to investigate the dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiotherapy. The influence of titanium-mandibular plate with the screws on radiation dose was tested on four real bones from mandible with the metal and screws fixed. Radiochromic films were used for dosimetry.
View Article and Find Full Text PDFPurpose: Evaluation of Inter-application variation of doses and spatial location of D(2cm(3)) volumes of OARs during MR-image based cervix brachytherapy.
Materials And Methods: Twenty-seven patients treated with EMBRACE protocol were analyzed. Every patient had two applications, one week apart.
Purpose: Trans-abdominal ultrasonography (US) is capable of determining size, shape, thickness, and diameter of uterus, cervix and disease at cervix or parametria. To assess the potential value of US for image-guided cervical cancer brachytherapy, we compared US-findings relevant for brachytherapy to the corresponding findings obtained from MR imaging.
Materials And Methods: Twenty patients with biopsy proven cervical cancer undergoing definitive radiotherapy with/without concomitant Cisplatin chemotherapy and suitable for brachytherapy were invited to participate in this study.
Int J Gynecol Cancer
August 2011
Objective: The objectives are to report the dosimetric analysis, preliminary clinical outcome, and comparison with published data of 3-dimensional magnetic resonance-based high dose rate brachytherapy (BT) in cervical cancer.
Materials And Methods: The data set of 24 patients with cervical cancer treated with high dose-rate brachytherapy applications was analyzed. All patients received radiation with or without chemotherapy (10 patients received concomitant chemoradiation).
Purpose: To compare inverse planning simulated annealing (IPSA) algorithm with the dose-point optimized (DPO) plan and manual/graphically optimized (GrO) plan for interstitial template brachytherapy for gynecologic cancers.
Methods And Materials: The data set of 10 consecutive patients was selected for this dosimetric study. For each patient, three plans were calculated: DPO, GrO, and IPSA.
Purpose: Comparison of inverse planning with the standard clinical plan and with the manually optimized plan based on dose-volume parameters and loading patterns.
Materials And Methods: Twenty-eight patients who underwent MRI based HDR brachytherapy for cervix cancer were selected for this study. Three plans were calculated for each patient: (1) standard loading, (2) manual optimized, and (3) inverse optimized.
Purpose: To characterize metal oxide semiconductor field-effect transistors (MOSFETs) for a 6-MV photon beam with a first helical tomotherapy Hi-Art II unit in India.
Materials And Methods: Standard sensitivity MOSFETs were first calibrated and then characterized for reproducibility, field size dependence, angular dependence, fade effects, and temperature dependence. The detector sensitivity was estimated for static as well as rotational modes for three jaw settings (1.
Objective: A three dimensional (3D) image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS).
Materials And Methods: Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study.
A Helical Tomotherapy (HT) Hi-Art II machine, Hi ART (TomoTherapy, Inc., Madison, WI, USA) was installed at our center in July 2007, and was the first machine in India. Image-guided HT is a new modality for delivering intensity modulated radiotherapy (IMRT).
View Article and Find Full Text PDFA Helical Tomotherapy (HT) Hi-Art II (TomoTherapy, Inc., Madison, WI, USA) has been one of the important innovations to help deliver IMRT with image guidance. On-board, mega voltage computed tomography (MVCT) detectors are used for imaging and dosimetric purpose.
View Article and Find Full Text PDFJ Appl Clin Med Phys
October 2009
Whole Abdomen Radiotherapy (WAR) for epithelial ovarian cancer though effective has been used sparingly due to inadequate target coverage and poor sparing of Organ At Risk (OAR) leading to significantly higher toxicities. Newer radiation techniques have shown potential for significant improvement in the therapeutic ratio. The purpose of this study was to evaluate Helical Tomotherapy(HT) for WAR.
View Article and Find Full Text PDF