Objective: Primarily to evaluate the area of neck coverage and secondarily, technical and clinical outcomes of the GORE EXCLUDER Conformable AAA Endoprosthesis (EXCC), designed to treat patients with significant angulation of the aortic neck, in routine clinical treatment of patients with abdominal aortic aneurysm (AAA).

Design: A prospective, multicentre, observational cohort study.

Materials And Methods: Patients aged >55 years with a nonruptured infrarenal AAA requiring treatment, were enrolled into the registry from June 2019 to December 2021.

View Article and Find Full Text PDF
Article Synopsis
  • A 67-year-old woman experienced leg pain due to severe popliteal artery stenosis caused by a popliteal ganglion cyst.
  • After opting out of vein bypass surgery, the patient was successfully treated with ultrasound-guided aspiration of the cyst, restoring normal blood flow.
  • This case is notable as it is the first reported instance where ganglion cyst aspiration successfully relieved claudication caused by a compressed popliteal artery, highlighting a new treatment option for cystic adventitial disease.
View Article and Find Full Text PDF

Background: A surgeon experiences elevated stress levels when operating. Acute stress is linked to cognitive overload, worsening surgical performance. Chronic stress poses a significant risk to a surgeon's health.

View Article and Find Full Text PDF

Purpose: The purpose of the study was to provide a consensus definition of the infrarenal sealing zone and develop an algorithm to determine when and if adjunctive procedure(s) or reintervention should be considered in managing patients undergoing endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm (AAA).

Methods: A European Advisory Board (AB), made up of 11 vascular surgeons with expertise in EVAR for AAA, was assembled to share their opinion regarding the definition of preoperative and postoperative infrarenal sealing zone. Information on their current clinical practice and level of agreement on proposed reintervention paths was used to develop an algorithm.

View Article and Find Full Text PDF

Introduction: In one-third of all abdominal aortic aneurysms (AAAs), the aneurysm neck is short (juxtarenal) or shows other adverse anatomical features rendering operations more complex, hazardous and expensive. Surgical options include open surgical repair and endovascular aneurysm repair (EVAR) techniques including fenestrated EVAR, EVAR with adjuncts (chimneys/endoanchors) and off-label standard EVAR. The aim of the UK COMPlex AneurySm Study (UK-COMPASS) is to answer the research question identified by the National Institute for Health Research Health Technology Assessment (NIHR HTA) Programme: 'What is the clinical and cost-effectiveness of strategies for the management of juxtarenal AAA, including fenestrated endovascular repair?'

Methods And Analysis: UK-COMPASS is a cohort study comparing clinical and cost-effectiveness of different strategies used to manage complex AAAs with stratification of physiological fitness and anatomical complexity, with statistical correction for baseline risk and indication biases.

View Article and Find Full Text PDF

Background: SSMD are used to enhance transparency, improve quality and facilitate patient choice. The use of SSMD is controversial, but patients' views on such data are largely unknown.

Objectives: The aim of this study was therefore to explore the views of patients and to identify their priorities for outcome reporting in vascular surgery.

View Article and Find Full Text PDF

Introduction: Unobtrusive metrics that can auto-assess performance during clinical procedures are of value. Three approaches to deriving wearable technology-based metrics are explored: (1) eye tracking, (2) psychophysiological measurements [e.g.

View Article and Find Full Text PDF

Objective: Video motion analysis (VMA) uses fluoroscopic sequences to derive information on catheter and guidewire movement and is able to calculate two-dimensional catheter tip path length (PL) on the basis of frame-by-frame pixel coordinates. The objective of this study was to evaluate the effect of anatomic complexity on the efficiency of completion of defined stages of simulated carotid artery stenting as measured by VMA.

Methods: Twenty interventionists each performed a standardized easy, medium, and difficult carotid artery stenting case in random order on an ANGIO Mentor (Simbionix, Airport City, Israel) simulator.

View Article and Find Full Text PDF

Objective: To measure the physiological stress response associated with high-fidelity endovascular team simulation.

Design: This is a prospective cohort study.

Setting: This study was performed at St Mary's Hospital (Imperial College London, London, UK), in a tertiary setting.

View Article and Find Full Text PDF

Flexible robotic catheters are an emerging technology which provide an elegant solution to the challenges of conventional endovascular intervention. Originally developed for interventional cardiology and electrophysiology procedures, remotely steerable robotic catheters such as the Magellan system enable greater precision and enhanced stability during target vessel navigation. These technical advantages facilitate improved treatment of disease in the arterial tree, as well as allowing execution of otherwise unfeasible procedures.

View Article and Find Full Text PDF

Right-sided aortic arches are rare, affecting approximately 0.1% of the population. They are a result of abnormal development of the primitive aortic arches and may present later in life with later life with aneurysmal expansion of the aberrant left subclavian artery 'Kommerell's diverticulum'.

View Article and Find Full Text PDF

Background: System factors contributing to preventable harm in vascular patients have not been previously reported in detail. The aim of this exploratory mixed-methods study was to describe vascular surgeons' perceptions of factors contributing to adverse events (AEs) in arterial surgery. A secondary aim was to report recommendations to improve patient safety.

View Article and Find Full Text PDF

Aims: Video motion analysis (VMA) uses fluoroscopic sequences to derive catheter and guidewire movement, and is able to calculate 2D catheter-tip path length (PL) on the basis of frame-by-frame pixel coordinates. The objective of this study was to validate VMA in coronary angiography as a method of skill assessment.

Methods And Results: Forty-seven coronary interventions performed by 10 low- (<1,000 cases; group A), five medium- (1,000-4,000; group B) and six high- (>4,000; group C) experience-volume cardiologists were prospectively recorded and analysed using VMA software.

View Article and Find Full Text PDF

Objective: Conventional catheter manipulation in the arch and supra-aortic trunks carries a risk of cerebral embolization. This study proposes a platform for detailed quantitative analysis of contact forces (CF) exerted on the vasculature, in order to investigate the potential advantages of robotic navigation.

Methods: An anthropomorphic phantom representing a type I bovine arch was mounted and coupled onto a force/torque sensor.

View Article and Find Full Text PDF

Objective: To assess the effect of patient-specific virtual reality rehearsal (PsR) before endovascular infrarenal aneurysm repair (EVAR) on technical performance and procedural errors.

Background: Endovascular procedures, including EVAR, are executed in a complex multidisciplinary environment, often treating high-risk patients. Consequently, this may lead to patient harm and procedural inefficiency.

View Article and Find Full Text PDF

Aims: The AARDVARK (Aortic Aneurysmal Regression of Dilation: Value of ACE-Inhibition on RisK) trial investigated whether ACE-inhibition reduces small abdominal aortic aneurysms (AAA) growth rate, independent of blood pressure (BP) lowering.

Methods And Results: A three-arm, multi-centre, single-blind, and randomized controlled trial (ISRCTN51383267) was conducted in 14 hospitals in England. Subjects aged ≥55 years with AAA diameter 3.

View Article and Find Full Text PDF

Purpose: Transcatheter aortic valve implantation (TAVI) demands precise and efficient handling of surgical instruments within the confines of the aortic anatomy. Operational performance and dexterous skills are critical for patient safety, and objective methods are assessed with a number of manipulation features, derived from the kinematic analysis of the catheter/guidewire in fluoroscopy video sequences.

Methods: A silicon phantom model of a type I aortic arch was used for this study.

View Article and Find Full Text PDF