Publications by authors named "Benoit Raucent"

As 3D printing technology expands rapidly in medical disciplines, the accuracy evaluation of 3D-printed medical models is required. However, no established guidelines to assess the dimensional error of anatomical models exist. This study aims to evaluate the dimensional accuracy of medical models 3D-printed using a hospital-based Fused Deposition Modeling (FDM) 3D printer.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation was introduced into clinical practice in 2002 as a rescue approach in patients presenting with symptomatic severe aortic stenosis but not eligible for conventional aortic valve replacement. This technique allows implantation of a balloon expandable bioprosthesis without resection of the native aortic valve. Several complications are described as a consequence of the residual highly calcified valve being squeezed against the aortic wall by the stent of the implant.

View Article and Find Full Text PDF

We developed a novel resection device to use during transapical transcatheter aortic valve implantation (TAVI) using a circular blade. We assessed the device in 15 human cadavers by transapical approach. After the resection, the aortic annulus was measured using standard probes.

View Article and Find Full Text PDF

Background: In orthopaedic surgery, many interventions involve freehand bone cutting with an oscillating saw. Such freehand procedures can produce large cutting errors due to the complex hand-controlled positioning of the surgical tool. This study was performed to investigate the potential improvements in cutting accuracy when computer-assisted and robot-assisted technologies are applied to a freehand bone-cutting process when no jigs are available.

View Article and Find Full Text PDF

Background: Manual manipulation of the camera is a major source of difficulties encountered by surgeons while performing minimally invasive laparoscopic surgery.

Methods: A survey of laparoscopic procedures and a review of existing active and passive holders were conducted. Based on these analyses, essential requirements were highlighted for such devices.

View Article and Find Full Text PDF

To determine essential specifications for an active endoscope holder, a survey of laparoscopic procedures was conducted. A review of the literature highlighted the advantages and limitations of existing scope-holding systems. From this analysis, basic requirements were listed for such devices.

View Article and Find Full Text PDF

Background: Computer- and robot-assisted technologies are capable of improving the accuracy of planar cutting in orthopaedic surgery. This study is a first step toward formulating and validating a new evaluation methodology for planar bone cutting, based on the standards from the International Organization for Standardization.

Methods: Our experimental test bed consisted of a purely geometrical model of the cutting process around a simulated bone.

View Article and Find Full Text PDF

Background And Purpose: Osseous pelvic tumors can be resected and reconstructed using massive bone allografts. Geometric accuracy of the conventional surgical procedure has not yet been documented. The aim of this experimental study was mainly to assess accuracy of tumoral resection with a 10-mm surgical margin, and also to evaluate the geometry of the host-graft reconstruction.

View Article and Find Full Text PDF