A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A novel device for endovascular native aortic valve resection for transapical transcatheter aortic valve implantation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We developed a novel resection device to use during transapical transcatheter aortic valve implantation (TAVI) using a circular blade. We assessed the device in 15 human cadavers by transapical approach. After the resection, the aortic annulus was measured using standard probes. A careful examination of the aortic wall, left ventricular outflow tract, coronary ostia and mitral valve was performed using an endpoint checklist, developed specifically for the new device. The resection was successfully completed in 14 out of 15 (93%) cases. All the resected leaflets and debris have been successfully evaluated in 15 out of 15 (100%) cases. One case of a bicuspid valve had a prominent calcification of the median raphe. The resection tool could only perform a partial resection. The mean duration of the resection was 45 ± 30 s. The surrounding tissue examination did not reveal any injury to the anatomical structures. Endovascular resection of the native valve using transapical approach is feasible and effective. Further developments are necessary before the definitive clinical use during percutaneous aortic valve implantation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3309814PMC
http://dx.doi.org/10.1093/icvts/ivr125DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
valve implantation
12
resection
8
transapical transcatheter
8
transcatheter aortic
8
transapical approach
8
valve
7
aortic
6
novel device
4
device endovascular
4

Similar Publications